Assessment of blood vessel mimics with optical coherence tomography

被引:20
作者
Bonnema, Garret T.
Cardinal, Kristen O.
McNally, James B.
Williams, Stuart K.
Barton, Jennifer K.
机构
[1] Univ Arizona, Div Biomed Engn, Tucson, AZ 85721 USA
[2] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
关键词
optical coherence tomography; endoscope; tissue engineering; blood vessel mimic; stents;
D O I
10.1117/1.2718555
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is an imaging modality that enables assessment of tissue structural characteristics. Studies have indicated that OCT is a useful method to assess both blood vessel morphology and the response of a vessel to a deployed stent. We evaluated the ability of OCT to visualize the cellular lining of a tissue-engineered blood vessel mimic (BVM) and the response of this lining to a bare metal stent. We develop a side-firing endoscope that obtains intraluminal, longitudinal scans within the sterile bioreactor environment, enabling time-serial assessment. Seventeen BVMs are imaged with the endoscopic OCT system. The BVMs are then evaluated via fluorescence microscopy and/or standard histologic techniques. We determine that (1) the OCT endoscope can be repeatedly inserted without visible damage to the BVM cellular lining, (2) OCT provides a precise measure of cellular lining thickness with good correlation to measurements obtained from histological sections, and (3) OCT is capable of monitoring the accumulation of cellular material in response to a metallic stent. Our studies indicate that OCT is a useful technique for monitoring the BVM cellular lining, and that OCT may facilitate the use of BVMs for early stage device assessment. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:6
相关论文
共 29 条
[1]   Imaging vascular implants with optical coherence tomography [J].
Barton, JK ;
Dal Fonte, DB ;
Williams, SK ;
Ford, B ;
Descour, MR .
COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 :229-236
[2]   Evaluation of intracoronary stenting by intravascular optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Yabushita, H ;
Shishkov, M ;
Kauffman, CR ;
Gauthier, DD ;
MacNeill, BD ;
Houser, SL ;
Aretz, HT ;
Halpern, EF ;
Jang, IK .
HEART, 2003, 89 (03) :317-320
[3]   Optical coherence tomography for optical biopsy - Properties and demonstration of vascular pathology [J].
Brezinski, ME ;
Tearney, GJ ;
Bouma, BE ;
Izatt, JA ;
Hee, MR ;
Swanson, EA ;
Southern, JF ;
Fujimoto, JG .
CIRCULATION, 1996, 93 (06) :1206-1213
[4]   Assessing atherosclerotic plaque morphology: Comparison of optical coherence tomography and high frequency intravascular ultrasound [J].
Brezinski, ME ;
Tearney, GJ ;
Weissman, NJ ;
Boppart, SA ;
Bouma, BE ;
Hee, MR ;
Weyman, AE ;
Swanson, EA ;
Southern, JF ;
Fujimoto, JG .
HEART, 1997, 77 (05) :397-403
[5]  
BREZINSKI ME, 2005, INT J CARDIOL
[6]  
Buellesfeld L, 2005, Z KARDIOL, V94, P690, DOI 10.1007/s00392-005-0276-4
[7]   Tissue-engineered vascular grafts as in vitro blood vessel mimics for the evaluation of endothelialization of intravascular devices [J].
Cardinal, Kristen O'Halloran ;
Bonnema, Garret T. ;
Hofer, Heidi ;
Barton, Jennifer Kehlet ;
Williams, Stuart K. .
TISSUE ENGINEERING, 2006, 12 (12) :3431-3438
[8]  
Di Mario Carlo, 2004, J Interv Cardiol, V17, P391, DOI 10.1111/j.1540-8183.2004.04081.x
[9]   Optical coherence tomography as a tool for percutaneous coronary interventions [J].
Diaz-Sandoval, LJ ;
Bourna, BE ;
Tearney, GJ ;
Jang, IK .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (04) :492-496
[10]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501