A Study of reconstruction in photoacoustic tomography with a focused transducer

被引:5
作者
Li, Meng-Lin [1 ,2 ]
Wang, Lihong V. [1 ,3 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, Opt Imaging Lab, College Stn, TX 77843 USA
[2] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu 30013, Taiwan
[3] Washington Univ, Dept Biomed Engn, Opt Imaging Lab, St Louis, MO 63130 USA
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2007 | 2007年 / 6437卷
基金
美国国家卫生研究院;
关键词
photoacoustic tomography; focused transducer; virtual detector; finite aperture effect;
D O I
10.1117/12.703716
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
So far most rigorous reconstruction algorithms for photoacoustic tomography (PAT), e.g., the modified back-projection algorithm, have been developed based on ideal point detectors. However, a flat unfocused transducer is commonly used in PAT, thus suffering from the finite aperture effect - tangential resolution deteriorates as the imaging point moves away from the scanning center. Based on a virtual-point-detector concept, we propose a PAT reconstruction with a focused transducer to improve the degraded tangential resolution. We treat the focal point of the focused transducer as a virtual-point detector, which means that delays applied in reconstruction are relative to the focal point. The geometric focus defines propagation path of photoacoustic signals. The simulation results show that compared with PAT with an unfocused transducer, PAT with a focused transducer having an f-number of 2.5 significantly improves tangential resolution by 29 mu m up to 791 mu m at the imaging positions of at least 4 mm away from the scanning center. The farther the imaging positions away from the scanning center, the larger the improvement. In the region of 4 mm away from the scanning center, PAT with a focused transducer slightly degrades the tangential resolution by up to 70 mu m. The improvement in tangential resolution comes with a compromise of loss in radial resolution by 26 mu m up to 79 mu m depending on the distance from the scanning center. In terms of the significant improvement in tangential resolution, the loss in radial resolution is tolerable, especially for imaging of big objects, e.g., breast.
引用
收藏
页数:7
相关论文
共 13 条
[1]   Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors [J].
Esenaliev, RO ;
Karabutov, AA ;
Oraevsky, AA .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :981-988
[2]   Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study [J].
Esenaliev, RO ;
Larina, IV ;
Larin, KV ;
Deyo, DJ ;
Motamedi, M ;
Prough, DS .
APPLIED OPTICS, 2002, 41 (22) :4722-4731
[3]   Backward mode detection of laser-induced wide-band ultrasonic transients with optoacoustic transducer [J].
Karabutov, AA ;
Savateeva, EV ;
Podymova, NB ;
Oraevsky, AA .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (04) :2003-2014
[4]   Measurement of optical path length change following pulsed laser irradiation using differential phase optical coherence tomography [J].
Kim, Jihoon ;
Oh, Junghwan ;
Milner, Thomas E. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)
[5]   Thermoacoustic computed tomography-technical considerations [J].
Kruger, RA ;
Reinecke, DR ;
Kruger, GA .
MEDICAL PHYSICS, 1999, 26 (09) :1832-1837
[6]   Imaging of tumor angiogenesis in rat brains in vivo by photoacoustic tomography [J].
Ku, G ;
Wang, XD ;
Xie, XY ;
Stoica, G ;
Wang, LHV .
APPLIED OPTICS, 2005, 44 (05) :770-775
[7]   Improved in vivo photoacoustic microscopy based on a virtual-detector concept [J].
Li, ML ;
Zhang, HF ;
Maslov, K ;
Stoica, G ;
Wang, LHV .
OPTICS LETTERS, 2006, 31 (04) :474-476
[8]  
Lungu GF, 2007, INT J ONCOL, V30, P45
[9]  
Maslov K, 2005, OPT LETT, V30, P625, DOI 10.1364/OL.30.6.000625
[10]   Photoacoustic measurement of epidermal melanin [J].
Viator, JA ;
Svaasand, LO ;
Aguilar, G ;
Choi, B ;
Nelson, JS .
BIOMEDICAL OPTOACOUSTICS IV, 2003, 4960 :14-20