C-Arm Cone Beam CT for Hepatic Tumor Ablation Under Real-Time 3D Imaging

被引:59
作者
Morimoto, Manabu [1 ]
Numata, Kazushi [1 ]
Kondo, Masaaki [1 ]
Nozaki, Akito [1 ]
Hamaguchi, Shingo [2 ]
Takebayashi, Shigeo [2 ]
Tanaka, Katsuaki [1 ]
机构
[1] Yokohama City Univ, Gastroenterol Ctr, Med Ctr, Minami Ku, Yokohama, Kanagawa 2320024, Japan
[2] Yokohama City Univ, Dept Radiol, Med Ctr, Yokohama, Kanagawa 2320024, Japan
关键词
3D imaging; cone beam CT; hepatocellular carcinoma; interventional radiology; radiofrequency ablation; FLUOROSCOPY; EXPERIENCE; GUIDANCE;
D O I
10.2214/AJR.09.3514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We describe our experience with the application of a novel technology in which fluoroscopy and 3D imaging from C-arm cone beam CT systems are combined with integrated navigation software. CONCLUSION. We applied this technology to five cases in which radiofrequency ablation was performed for hepatocellular carcinoma. Technical success was achieved without treatment-related complications in all cases. We conclude that this novel technology is potentially useful for targeting hepatic lesions.
引用
收藏
页码:W452 / W454
页数:3
相关论文
共 9 条
[1]   Virtual sonographic radiofrequency ablation of hepatocellular carcinoma visualized on CT but not on conventional sonography [J].
Hirooka, M ;
Iuchi, H ;
Kumagi, T ;
Shigematsu, S ;
Hiraoka, A ;
Uehara, T ;
Kurose, K ;
Horiike, N ;
Onji, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) :S255-S260
[2]   Cone-beam CT with flat-panel-detector digital angiography system: Early experience in abdominal interventional procedures [J].
Hirota, Shozo ;
Nakao, Norio ;
Yamamoto, Satoshi ;
Kobayashi, Kaoru ;
Maeda, Hiroaki ;
Ishikura, Reiichi ;
Miura, Koui ;
Sakamoto, Kiyoshi ;
Ueda, Ken ;
Baba, Rika .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (06) :1034-1038
[3]   Guidance with real-time CT fluoroscopy: Early clinical experience [J].
Katada, K ;
Kato, R ;
Anno, H ;
Ogura, Y ;
Koga, S ;
Ida, Y ;
Sato, M ;
Nonomura, K .
RADIOLOGY, 1996, 200 (03) :851-856
[4]   Three-dimensional CT with a modified C-arm image intensifier: Feasibility [J].
Linsenmaier, U ;
Rock, C ;
Euler, E ;
Wirth, S ;
Brandl, R ;
Kotsianos, D ;
Mutschler, W ;
Pfeifer, KJ .
RADIOLOGY, 2002, 224 (01) :286-292
[5]  
Racadio JM, 2007, AJR, V189, P1523
[6]   Live 3D guidance in the interventional radiology suite [J].
Racadio, John M. ;
Babic, Drazenko ;
Homan, Robert ;
Rampton, John W. ;
Patel, Manish N. ;
Racadio, Judy M. ;
Johnson, Neil D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) :W357-W364
[7]   C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous Catheters [J].
Tam, Alda ;
Mohamed, Ashraf ;
Pfister, Marcus ;
Rohm, Esther ;
Wallace, Michael J. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (04) :820-824
[8]   CT fluoroscopy: Another advancement with additional challenges in radiation management [J].
Wagner, LK .
RADIOLOGY, 2000, 216 (01) :9-10
[9]   Impact of C-arm CT an hepatic arterial interventions for hepatic malignancies [J].
Wallace, Michael J. ;
Murthy, Ravi ;
Kamat, Paresh P. ;
Moore, Teri ;
Rao, Sujaya H. ;
Ensor, Joe ;
Gupta, Sanjay ;
Ahrar, Kamran ;
Madoff, David C. ;
McRae, Stephen E. ;
Hicks, Marshall E. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (12) :1500-1507