Strong anion-exchange liquid chromatography coupled with isotope ratio mass spectrometry using a Liquiface interface

被引:29
|
作者
Morrison, Douglas J. [1 ]
Taylor, Karen [1 ]
Preston, Tom [1 ]
机构
[1] SUERC, Stable Isotope Biochem Lab, Glasgow G75 0QF, Lanark, Scotland
关键词
GAS-CHROMATOGRAPHY; AMINO-ACIDS; PERFORMANCE; DELTA-C-13; CARBON; METHODOLOGY; ETHANOL;
D O I
10.1002/rcm.4572
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The introduction of liquid chromatography coupled with isotope ratio mass spectrometry (LC/IRMS) as an analytical tool for the measurement of isotope ratios in non-volatile analytes has somewhat simplified the analytical cycle from sample collection to analysis mainly due to the avoidance of the extensive sample processing and derivatisation that were necessary for gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Here we test the performance of coupling strong anion exchange to IRMS using only the second commercially available interface; the Liquiface. The system was modified from installation specification to improve peak resolution in the interface and maintain peak separation from the column to the mass spectrometer. The system performance was assessed by the determination of sensitivity, accuracy and precision attained from carbohydrate separations. The system performed satisfactorily after modifications, resulting in maintenance of peak resolution from column to mass spectrometer. The sensitivity achieved suggested that similar to 150 ng carbon could be analysed with acceptable precision (<0.3%.). Accuracy was maintained in the interface as determined by correlation with offline techniques, resulting in regression coefficient of r(2) = 0.98 and a slope of 0.99. The average precision achieved for the separation of seven monosaccharides was 0.36%.. The integration of a carbonate removal device limited the effect of background carbon perturbations in the mass spectrometer associated with eluent gradients, and the coupling of strong anion-exchange chromatography with IRMS was successfully achieved using the Liquiface. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1755 / 1762
页数:8
相关论文
共 50 条
  • [31] Simultaneous determination of 13 carbohydrates using high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry
    Zhao, Dan
    Feng, Feng
    Yuan, Fei
    Su, Jin
    Cheng, Yan
    Wu, Hanqiu
    Song, Kun
    Nie, Bo
    Yu, Lian
    Zhang, Feng
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (08) : 1843 - 1854
  • [32] Determination of d-myo-inositol phosphates in 'activated' raw almonds using anion-exchange chromatography coupled with tandem mass spectrometry
    Lee, Lianna Y.
    Mitchell, Alyson E.
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2019, 99 (01) : 117 - 123
  • [33] The separation of arsenic species in soils and plant tissues by anion-exchange chromatography with inductively coupled mass spectrometry using various mobile phases
    Chen, ZuLiang
    Akter, Kazi Farzana
    Rahman, Mohammad Mahmudur
    Naidu, Ravendra
    MICROCHEMICAL JOURNAL, 2008, 89 (01) : 20 - 28
  • [34] Selenium speciation analysis in a sediment using strong anion exchange and reversed phase chromatography coupled with inductively coupled plasma-mass spectrometry
    Ochsenkühn-Petropoulou, M
    Michalke, B
    Kavouras, D
    Schramel, P
    ANALYTICA CHIMICA ACTA, 2003, 478 (02) : 219 - 227
  • [35] Liquid-chromatography isotope-ratio-mass-spectrometry via a moving wire interface.
    Sessions, AL
    Pearson, A
    Hayes, JM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U530 - U530
  • [36] Review: Current applications and challenges for liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS)
    Godin, Jean-Philippe
    McCullagh, James S. O.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 3019 - 3028
  • [37] Temperature-programmed high-performance liquid chromatography coupled to isotope ratio mass spectrometry
    Godin, Jean-Philippe
    Hopfgartner, Gerard
    Fay, Laurent
    ANALYTICAL CHEMISTRY, 2008, 80 (18) : 7144 - 7152
  • [38] High-temperature reversed-phase liquid chromatography coupled to isotope ratio mass spectrometry
    Zhang, Lijun
    Kujawinski, Dorothea M.
    Jochmann, Maik A.
    Schmidt, Torsten C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 2971 - 2980
  • [39] Authenticity determination of tea drinks in the Chinese market by liquid chromatography coupled to isotope ratio mass spectrometry
    Ding, Bo
    Zeng, Guangfeng
    Wang, Zhiyuan
    Xie, Jianjun
    Wang, Lu
    Chen, Wenrui
    MICROCHEMICAL JOURNAL, 2019, 144 : 139 - 143
  • [40] Identification of Natural Caffeine Source in Coffee Drinks by Liquid Chromatography Coupled with Isotope Ratio Mass Spectrometry
    Ding Bo
    Wang Zhi-Yuan
    Chen Wen-Rui
    Xie Jian-Jun
    She Zhi-Gang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (11) : 1802 - 1807