Strong anion-exchange liquid chromatography coupled with isotope ratio mass spectrometry using a Liquiface interface

被引:29
|
作者
Morrison, Douglas J. [1 ]
Taylor, Karen [1 ]
Preston, Tom [1 ]
机构
[1] SUERC, Stable Isotope Biochem Lab, Glasgow G75 0QF, Lanark, Scotland
关键词
GAS-CHROMATOGRAPHY; AMINO-ACIDS; PERFORMANCE; DELTA-C-13; CARBON; METHODOLOGY; ETHANOL;
D O I
10.1002/rcm.4572
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The introduction of liquid chromatography coupled with isotope ratio mass spectrometry (LC/IRMS) as an analytical tool for the measurement of isotope ratios in non-volatile analytes has somewhat simplified the analytical cycle from sample collection to analysis mainly due to the avoidance of the extensive sample processing and derivatisation that were necessary for gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Here we test the performance of coupling strong anion exchange to IRMS using only the second commercially available interface; the Liquiface. The system was modified from installation specification to improve peak resolution in the interface and maintain peak separation from the column to the mass spectrometer. The system performance was assessed by the determination of sensitivity, accuracy and precision attained from carbohydrate separations. The system performed satisfactorily after modifications, resulting in maintenance of peak resolution from column to mass spectrometer. The sensitivity achieved suggested that similar to 150 ng carbon could be analysed with acceptable precision (<0.3%.). Accuracy was maintained in the interface as determined by correlation with offline techniques, resulting in regression coefficient of r(2) = 0.98 and a slope of 0.99. The average precision achieved for the separation of seven monosaccharides was 0.36%.. The integration of a carbonate removal device limited the effect of background carbon perturbations in the mass spectrometer associated with eluent gradients, and the coupling of strong anion-exchange chromatography with IRMS was successfully achieved using the Liquiface. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1755 / 1762
页数:8
相关论文
共 50 条
  • [21] Simultaneous quantification of emtricitabine and tenofovir nucleotides in peripheral blood mononuclear cells using weak anion-exchange liquid chromatography coupled with tandem mass spectrometry
    Jansen, Robert S.
    Rosing, Hilde
    Kromdijk, Wiete
    ter Heine, Rob
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 621 - 627
  • [22] Anion-Exchange Chromatography of Phosphopeptides: Weak Anion Exchange versus Strong Anion Exchange and Anion-Exchange Chromatography versus Electrostatic Repulsion-Hydrophilic Interaction Chromatography
    Alpert, Andrew J.
    Hudecz, Otto
    Mechtler, Karl
    ANALYTICAL CHEMISTRY, 2015, 87 (09) : 4704 - 4711
  • [23] Novel method for measurement of glutathione kinetics in neonates using liquid chromatography coupled to isotope ratio mass spectrometry
    Schierbeek, Henk
    Braakel, Frans te
    Godin, Jean-Philippe
    Fay, Laurent-Bernard
    van Goudoever, Johannes B.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (17) : 2805 - 2812
  • [24] Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates
    Moerdijk-Poortvliet, Tanja C. W.
    Schierbeek, Henk
    Houtekamer, Marco
    van Engeland, Tom
    Derrien, Delphine
    Stal, Lucas J.
    Boschker, Henricus T. S.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (13) : 1205 - 1214
  • [25] Liquid Chromatography Coupled to Isotope Ratio Mass Spectrometry Expanded to Include Organic Mobile Phases
    Tobias, Herbert J.
    Jones, Andrew
    Saunders, Thomas R.
    Brenna, J. Thomas
    ANALYTICAL CHEMISTRY, 2024, 96 (19) : 7348 - 7352
  • [26] Direct determination of dialkyl phosphates by strong anion-exchange liquid chromatography/atmospheric pressure chemical ionization mass spectrometry using a quadrupole ion trap instrument
    Draper, William M.
    Behniwal, Paramjit
    Wijekoon, Donald
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (17) : 2613 - 2620
  • [27] Liquid chromatography coupled to isotope ratio mass spectrometry:: A new perspective on honey adulteration detection
    Cabanero, Ana I.
    Recio, Jose L.
    Ruperez, Mercedes
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (26) : 9719 - 9727
  • [28] Speciation of vanadium by anion-exchange chromatography with inductively coupled plasma mass spectrometry and con. rmation of vanadium complex formation using electrospray mass spectrometry
    Chen, ZuLiang
    Rahman, Mohammad Mahmudur
    Naidu, Ravendra
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (07) : 811 - 816
  • [29] Evaluation of honey authenticity in Lebanon by analysis of carbon stable isotope ratio using elemental analyzer and liquid chromatography coupled to isotope ratio mass spectrometry
    El Hawari, Khaled
    Al Iskandarani, Mohamad
    Jaber, Farouk
    Ezzeddine, Raed
    Ziller, Luca
    Perini, Matteo
    Bontempo, Luana
    Pellegrini, Maura
    Camin, Federica
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (06):
  • [30] Screening of eltanolone metabolites in dog urine by anion-exchange/reversed-phase liquid chromatography and mass spectrometry
    Tjernberg, A
    Edlund, PO
    Norén, B
    JOURNAL OF CHROMATOGRAPHY B, 1998, 715 (02): : 395 - 407