Strong anion-exchange liquid chromatography coupled with isotope ratio mass spectrometry using a Liquiface interface

被引:29
|
作者
Morrison, Douglas J. [1 ]
Taylor, Karen [1 ]
Preston, Tom [1 ]
机构
[1] SUERC, Stable Isotope Biochem Lab, Glasgow G75 0QF, Lanark, Scotland
关键词
GAS-CHROMATOGRAPHY; AMINO-ACIDS; PERFORMANCE; DELTA-C-13; CARBON; METHODOLOGY; ETHANOL;
D O I
10.1002/rcm.4572
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The introduction of liquid chromatography coupled with isotope ratio mass spectrometry (LC/IRMS) as an analytical tool for the measurement of isotope ratios in non-volatile analytes has somewhat simplified the analytical cycle from sample collection to analysis mainly due to the avoidance of the extensive sample processing and derivatisation that were necessary for gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Here we test the performance of coupling strong anion exchange to IRMS using only the second commercially available interface; the Liquiface. The system was modified from installation specification to improve peak resolution in the interface and maintain peak separation from the column to the mass spectrometer. The system performance was assessed by the determination of sensitivity, accuracy and precision attained from carbohydrate separations. The system performed satisfactorily after modifications, resulting in maintenance of peak resolution from column to mass spectrometer. The sensitivity achieved suggested that similar to 150 ng carbon could be analysed with acceptable precision (<0.3%.). Accuracy was maintained in the interface as determined by correlation with offline techniques, resulting in regression coefficient of r(2) = 0.98 and a slope of 0.99. The average precision achieved for the separation of seven monosaccharides was 0.36%.. The integration of a carbonate removal device limited the effect of background carbon perturbations in the mass spectrometer associated with eluent gradients, and the coupling of strong anion-exchange chromatography with IRMS was successfully achieved using the Liquiface. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1755 / 1762
页数:8
相关论文
共 50 条
  • [1] Determination of strong binding chelators and their metal complexes by anion-exchange chromatography and inductively coupled plasma mass spectrometry
    Ammann, AA
    JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (02) : 205 - 216
  • [2] ADAPTATION OF A THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY INTERFACE FOR USE WITH ALKALINE ANION-EXCHANGE LIQUID-CHROMATOGRAPHY OF CARBOHYDRATES
    SIMPSON, RC
    FENSELAU, CC
    HARDY, MR
    TOWNSEND, RR
    LEE, YC
    COTTER, RJ
    ANALYTICAL CHEMISTRY, 1990, 62 (03) : 248 - 252
  • [3] Improvement of sugar analysis sensitivity using anion-exchange chromatography-electrospray ionization mass spectrometry with sheath liquid interface
    Xu, Xian-Bing
    Liu, Ding-Bo
    Guo, Xiao Ming
    Yu, Shu-Juan
    Yu, Pei
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1366 : 65 - 72
  • [4] Speciation of arsenic in chicken meat by anion-exchange liquid chromatography with inductively coupled plasma-mass spectrometry
    Polatajko, A
    Szpunar, J
    JOURNAL OF AOAC INTERNATIONAL, 2004, 87 (01) : 233 - 237
  • [6] Potential of ion chromatography coupled to isotope ratio mass spectrometry via a liquid interface for beverages authentication
    Guyon, Francois
    Gaillard, Laetitia
    Brault, Audrey
    Gaultier, Nicolas
    Salagoity, Marie-Helene
    Medina, Bernard
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1322 : 62 - 68
  • [7] Carbon isotope ratio measurements of glyphosate and AMPA by liquid chromatography coupled to isotope ratio mass spectrometry
    Dorothea M. Kujawinski
    J. Benjamin Wolbert
    Lijun Zhang
    Maik A. Jochmann
    David Widory
    Nicole Baran
    Torsten C. Schmidt
    Analytical and Bioanalytical Chemistry, 2013, 405 : 2869 - 2878
  • [8] Isotope ratio monitoring of small molecules and macromolecules by liquid chromatography coupled to isotope ratio mass spectrometry
    Godin, JP
    Hau, J
    Fay, LB
    Hopfgartner, G
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) : 2689 - 2698
  • [9] Carbon isotope ratio measurements of glyphosate and AMPA by liquid chromatography coupled to isotope ratio mass spectrometry
    Kujawinski, Dorothea M.
    Wolbert, J. Benjamin
    Zhang, Lijun
    Jochmann, Maik A.
    Widory, David
    Baran, Nicole
    Schmidt, Torsten C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (09) : 2869 - 2878
  • [10] The use of strong anion-exchange (SAX) magnetic particles for the extraction of therapeutic siRNA and their analysis by liquid chromatography/mass spectrometry
    Ye, Guofeng
    Beverly, Michael
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (21) : 3207 - 3215