Retrofitting measures for reducing buildings cooling requirements in cooling-dominated environment: Residential house

被引:28
作者
Kharseh, Mohamad [1 ]
Al-Khawaja, Mohammed [1 ]
机构
[1] Qatar Univ, Mech & Ind Engn Dept, Doha, Qatar
关键词
Residential house; Simulation; Cooling requirement; Retrofitting measures; Cost analysis; SAUDI-ARABIA; WALL SYSTEM; ENERGY; OPTIMIZATION; CONSUMPTION; INSULATION; THICKNESS; ENVELOPE; CLIMATE; DESIGN;
D O I
10.1016/j.applthermaleng.2015.12.063
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air conditioning systems in hot and developing countries are the major energy consumers. Unfortunately, Arabian Peninsula countries still rely completely on fossil fuel. Therefore, there are compelling reasons to investigate the energy consumption in buildings and its environmental impact. The current paper studies the effect of different retrofitting measures for reducing cooling load of buildings in hot climate. A common type of residential house with dimension of 12 x 12 x 3 m in Qatar was chosen as a case study. Five energy retrofitting measures of the building envelope have been considered in this study: (1) U-value of the external shell, (2) indoor set-temperature, (3) lighting efficacy, (4) the color of external shell, and (5) windows' quality. Hourly analysis program was used for calculating the cooling load of the case study. The anticipated costs associated with the implementation of the retrofitting measures were calculated based on the local current prices in Qatar. Simple payback period for each measure was assessed in the present study. The simulations show that the energy saving of 53% can be obtained at the working conditions of Qatar. The payback period of the examined measures is relatively short and varies between 0.5 and 4 years. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:352 / 356
页数:5
相关论文
共 33 条
  • [21] Huang J., 1999, RESIDENTIAL HEATING
  • [22] Potential of ground source heat pump systems in cooling-dominated environments: Residential buildings
    Kharseh, Mohamad
    Al-Khawaja, Mohammed
    Suleiman, Muhannad T.
    [J]. GEOTHERMICS, 2015, 57 : 104 - 110
  • [23] Comparison between different measures to reduce cooling requirements of residential building in cooling-dominated environment
    Kharseh, Mohamad
    Al-Khawaja, Mohammed
    Hassani, Ferri
    [J]. ENERGY AND BUILDINGS, 2015, 88 : 409 - 412
  • [24] Optimization of a phase change material wallboard for building use
    Kuznik, Frederic
    Virgone, Joseph
    Noel, Jean
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1291 - 1298
  • [25] METEONORM, 2004, GLOB MET DAT ENG PLA
  • [26] Minitab, 2010, MIN 16 STAT SOFTW
  • [27] Effect of insulation location on dynamic heat-transfer characteristics of building external walls and optimization of insulation thickness
    Ozel, Meral
    [J]. ENERGY AND BUILDINGS, 2014, 72 : 288 - 295
  • [28] Thermal, economical and environmental analysis of insulated building walls in a cold climate
    Ozel, Meral
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 674 - 684
  • [29] Rudd A., 2004, ACEEE SUMMER STUDY E, V1, P293
  • [30] Feasibility of using ground-coupled condensers in A/C systems
    Said, Syed Ahmad M.
    Habib, Mohamed A.
    Mokheimer, Esmail M. A.
    El-Sharqawi, Mostafa H.
    [J]. GEOTHERMICS, 2010, 39 (02) : 201 - 204