Voltammetric Determination of Hg2+, Zn2+, and Pb2+ Ions Using a PEDOT/NTA-Modified Electrode

被引:40
作者
Alshawi, Jasim M. S. [1 ]
Mohammed, Mohammed Q. [1 ]
Alesary, Hasan F. [4 ]
Ismail, Hani K. [2 ]
Barton, Stephen [3 ]
机构
[1] Univ Basrah, Coll Educ Pure Sci, Dept Chem, Basrah 61001, Iraq
[2] Koya Univ, Fac Sci & Hlth, Dept Chem, KOY45, Koya, Kurdistan Regio, Iraq
[3] Kingston Univ London, Sch Life Sci Pharm & Chem, Kingston Upon Thames KT1 1LQ, Surrey, England
[4] Univ Kerbala, Coll Sci, Dept Chem, Karbala 56001, Iraq
来源
ACS OMEGA | 2022年 / 7卷 / 23期
关键词
HEAVY-METAL IONS; ELECTROCHEMICAL SENSOR; LEAD IONS; RAPID REMOVAL; CADMIUM; COMPOSITE; COPPER; DESIGN; FILMS; WATER;
D O I
10.1021/acsomega.2c02682
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel electrochemical sensor for determining trace levels of Hg2+, Pb2+, and Zn2+ ions in water using square wave voltammetry (SWV) is reported. The sensor is based on a platinum electrode (Pt) modified by poly(3,4-ethylenedioxythiophene) and N alpha,N alpha-bis-(carboxymethyl)-L-lysine hydrate (NTA lysine) PEDOT/NTA. The modified electrode surface (PEDOT/NTA) was prepared via the introduction of the lysine-NTA group to a PEDOT/N-hydroxyphthalimide NHP electrode. The (PEDOT/NTA) was characterized via cyclic voltammetry (CV), Fourier transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM). The effects of scan rates on the electrochemical properties of the polymer electrode were also investigated. The electrochemical results were used to estimate the coverage of the electrode polymer surface and its electrostability in background electrolyte solutions. Several analytical parameters, such as polymer film thickness, metal deposition time, and pH of the electrolyte, were examined. Linear responses to Hg2+, Pb2+, and Zn2+ ions in the concentration range of 5-100 mu g L-1 were obtained. The limits of detection (LODs) for the determination of Hg2+, Pb2+, and Zn2+ ions were 1.73, 2.33, and 1.99 mu g L-1, respectively. These promising results revealed that modified PEDOT/NTA films might well represent an important addition to existing electrochemical sensor technologies.
引用
收藏
页码:20405 / 20419
页数:15
相关论文
共 71 条
  • [1] AL-Refai H. H., 2020, MATER TODAY COMMUN
  • [2] A comparative study of the effect of organic dopant ions on the electrochemical and chemical synthesis of the conducting polymers polyaniline, poly(o-toluidine) and poly(o-methoxyaniline)
    Alesary, Hasan F.
    Ismail, Hani K.
    Mohammed, Mohammed Q.
    Mohammed, Halgurd N.
    Abbas, Zaid K.
    Barton, Stephen
    [J]. CHEMICAL PAPERS, 2021, 75 (10) : 5087 - 5101
  • [3] Effects of Dopant Ions on the Properties of Polyaniline Conducting Polymer
    Alesary, Hasan Fisal
    Ismail, Hani Khalil
    Khudhair, Ahmed Fadhil
    Mohammed, Mohammed Qasim
    [J]. ORIENTAL JOURNAL OF CHEMISTRY, 2018, 34 (05) : 2525 - 2533
  • [4] Anandhakumar S., 2011, AM J ANAL CHEM, V2, P470, DOI DOI 10.4236/AJAC.2011.24056
  • [5] Voltammetric determination of metal ions beyond mercury electrodes. A review
    Arino, Cristina
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    [J]. ANALYTICA CHIMICA ACTA, 2017, 990 : 11 - 53
  • [6] L-cysteine doped polypyrrole (PPy@ L-Cyst): A super adsorbent for the rapid removal of Hg+2 and efficient catalytic activity of the spent adsorbent for reuse
    Ballav, Niladri
    Das, Raghunath
    Giri, Somnath
    Muliwa, Anthony M.
    Pillay, Kriveshini
    Maity, Arjun
    [J]. CHEMICAL ENGINEERING JOURNAL, 2018, 345 : 621 - 630
  • [7] A review on various electrochemical techniques for heavy metal ions detection with different sensing platforms
    Bansod, BabanKumar
    Kumar, Tejinder
    Thakur, Ritula
    Rana, Shakshi
    Singh, Inderbir
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 94 : 443 - 455
  • [8] Electrochromic enhancement of latent fingerprints by poly(3,4-ethylenedioxythiophene)
    Brown, Rachel M.
    Hillman, A. Robert
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2012, 14 (24) : 8653 - 8661
  • [9] Conjugated Polyfluorene-based Reversible Fluorescent Sensor for Cu(II) and Cyanide Ions in Aqueous Medium
    Chakraborty, Chanchal
    Singh, Pradeep
    Maji, Samir K.
    Malik, Sudip
    [J]. CHEMISTRY LETTERS, 2013, 42 (11) : 1355 - 1357
  • [10] EDTA_PANI/SWCNTs nanocomposite modified electrode for electrochemical determination of copper (II), lead (II) and mercury (II) ions
    Deshmukh, Megha A.
    Celiesiute, Raimonda
    Ramanaviciene, Almira
    Shirsat, Mahendra D.
    Ramanavicius, Arunas
    [J]. ELECTROCHIMICA ACTA, 2018, 259 : 930 - 938