A sensitivity analysis of RLC transformer winding model parameters used for a PD localization

被引:0
|
作者
Seifi, Sahand [1 ]
Akbari, Asghar [1 ]
Werle, Peter [1 ]
Mohseni, Hossein [2 ]
Akmal, Amir Abbas Shayegani [2 ]
机构
[1] Leibniz Univ Hannover, Management Schering Inst, Dept High Voltage Technol & Asset, Hannover, Germany
[2] Univ Tehran, High Voltage Inst, Tehran, Iran
来源
2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD) | 2018年
关键词
frequency response analysis; partial discharge localization; senesitivity analysis; transformer model; PARTIAL DISCHARGE LOCALIZATION; POWER-TRANSFORMERS; IDENTIFICATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) measurement is a well known method for the condition assessment of a power transformer insulation system, thereby finding the location of PD allows a comprehensive risk analysis of this key component. Electrical measurements of PD are a common approach, but the preciseness of this method for a PD localization can be still improved. The various advantages of this method over the other ones, like UHF and acoustic, is gained a lot of attraction to be investigated in spite of special challenges. Most important part of this method is finding the needed sectional winding transfer functions (SWTF). One way to obtain the SWTFs is finding the RLC model of the winding. In this paper, a sensitivity analysis of the PD location to the RLC model parameters has been done.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Abnormality Diagnosis of Transformer Winding by Frequency Response Analysis (FRA) Using Circuit Model
    Miyazaki, Satoru
    Mizutani, Yoshinobu
    Okamoto, Tatsuki
    Wada, Yoshihiro
    Hayashida, Chikara
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 273 - 276
  • [32] Double-End Excitation of Transformer Winding Model for Improved Frequency Response Analysis
    Pramanik, Saurav
    Ganesh, Aravind
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 594 - 605
  • [33] A Piece-wise Linearized Transformer Winding Model for the Analysis of Internal Voltage Propagation
    Theocharis, Andreas
    Popov, Marjan
    2019 IEEE MILAN POWERTECH, 2019,
  • [34] Three winding transformer s-domain model for modal analysis of electrical networks
    Varricchio, Sergio Luis
    Gomes, Sergio, Jr.
    Rangel, Ricardo Diniz
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (03) : 420 - 429
  • [35] Construction of Transfer Functions and Sensitivity Analysis of Frequency Response Analysis Method for On-line Monitoring Transformer Winding Deformations
    Zheng D.
    Cheng Y.
    Peng L.
    Bi J.
    Chang W.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (04): : 1534 - 1545
  • [36] Global Sensitivity Analysis for Statistical Model Parameters
    Hart, Joseph L.
    Bessac, Julie
    Constantinescu, Emil M.
    SIAM-ASA JOURNAL ON UNCERTAINTY QUANTIFICATION, 2019, 7 (01): : 67 - 92
  • [37] SENSITIVITY ANALYSIS OF PARAMETERS FOR FPSO MODEL UPDATING
    Wu, Qihao
    Zhang, Min
    Yang, Tian'en
    Xu, Nuoya
    Wang, Junrong
    Du, Junfeng
    Fonseca, Nuno
    Tahchiev, Galin
    PROCEEDINGS OF THE ASME 39TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, OMAE2020, VOL 6B, 2020,
  • [38] Sensitivity Analysis of Model Parameters in Geoacoustic Inversion
    Sanjana, M. C.
    Latha, G.
    Potty, Gopu R.
    2013 OCEAN ELECTRONICS (SYMPOL), 2013, : 96 - +
  • [39] Sensitivity analysis about FLAASH model parameters
    Wang, Jie
    Qi, Jianwei
    Zhang, Dandan
    Fu, Zhengbo
    2018 FIFTH INTERNATIONAL WORKSHOP ON EARTH OBSERVATION AND REMOTE SENSING APPLICATIONS (EORSA), 2018, : 81 - 85
  • [40] Sensitivity analysis of the CORSIM simulation model parameters
    Breski, Deana
    Cvitanic, Drazen
    Lovric, Ivan
    Gradevinar, 2006, 58 (07): : 539 - 548