Resource-efficient internally controlled in-house real-time PCR detection of SARS-CoV-2

被引:34
作者
Michel, Janine [1 ]
Neumann, Markus [1 ]
Krause, Eva [1 ]
Rinner, Thomas [1 ]
Muzeniek, Therese [1 ]
Grossegesse, Marica [1 ]
Hille, Georg [1 ]
Schwarz, Franziska [1 ]
Puyskens, Andreas [1 ]
Forster, Sophie [1 ]
Biere, Barbara [2 ]
Bourquain, Daniel [1 ]
Domingo, Cristina [1 ]
Brinkmann, Annika [1 ]
Schaade, Lars [1 ]
Schrick, Livia [1 ]
Nitsche, Andreas [1 ]
机构
[1] Robert Koch Inst, Ctr Biol Threats & Special Pathogens, Highly Pathogen Viruses ZBS 1, Seestr 10, D-13353 Berlin, Germany
[2] Robert Koch Inst, Influenza & Resp Viruses FG 17, Seestr 10, D-13353 Berlin, Germany
关键词
SARS-CoV-2; COVID-19; Diagnostics; Real-time PCR; Internal control;
D O I
10.1186/s12985-021-01559-3
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
BackgroundThe reliable detection of SARS-CoV-2 has become one of the most important contributions to COVID-19 crisis management. With the publication of the first sequences of SARS-CoV-2, several diagnostic PCR assays have been developed and published. In addition to in-house assays the market was flooded with numerous commercially available ready-to-use PCR kits, with both approaches showing alarming shortages in reagent supply.AimHere we present a resource-efficient in-house protocol for the PCR detection of SARS-CoV-2 RNA in patient specimens (RKI/ZBS1 SARS-CoV-2 protocol).MethodsTwo duplex one-step real-time RT-PCR assays are run simultaneously and provide information on two different SARS-CoV-2 genomic regions. Each one is duplexed with a control that either indicates potential PCR inhibition or proves the successful extraction of nucleic acid from the clinical specimen.ResultsLimit of RNA detection for both SARS-CoV-2 assays is below 10 genomes per reaction. The protocol enables testing specimens in duplicate across the two different SARS-CoV-2 PCR assays, saving reagents by increasing testing capacity. The protocol can be run on various PCR cyclers with several PCR master mix kits.ConclusionThe presented RKI/ZBS1 SARS-CoV-2 protocol represents a cost-effective alternative in times of shortages when commercially available ready-to-use kits may not be available or affordable.
引用
收藏
页数:11
相关论文
共 18 条
[11]   Clinical Evaluation of the cobas SARS-CoV-2 Test and a Diagnostic Platform Switch during 48 Hours in the Midst o the COVID-19 Pandemic [J].
Poljak, Mario ;
Korva, Misa ;
Gasper, Natasa Knap ;
Komlos, Kristina Fujs ;
Sagadin, Martin ;
Ursic, Tina ;
Zupanc, Tatjana Avsic ;
Petrovec, Miroslav .
JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (06)
[12]   Guideline to reference gene selection for quantitative real-time PCR [J].
Radonic, A ;
Thulke, S ;
Mackay, IM ;
Landt, O ;
Siegert, W ;
Nitsche, A .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2004, 313 (04) :856-862
[13]   Interpret with caution: An evaluation of the commercial AusDiagnostics versus in-house developed assays for the detection of SARS-CoV-2 virus [J].
Rahman, H. ;
Carter, I ;
Basile, K. ;
Donovan, L. ;
Kumar, S. ;
Tran, T. ;
Ko, D. ;
Alderson, S. ;
Sivaruban, T. ;
Eden, J-S ;
Rockett, R. ;
O'Sullivan, M., V ;
Sintchenko, V ;
Chen, S. C-A ;
Maddocks, S. ;
Dwyer, D. E. ;
Kok, J. .
JOURNAL OF CLINICAL VIROLOGY, 2020, 127
[14]  
Schrick Livia, 2016, Biomol Detect Quantif, V6, P1, DOI 10.1016/j.bdq.2015.11.001
[15]  
World Health Organization, 2020, COR DIS COVID 19 TEC
[16]   A new coronavirus associated with human respiratory disease in China [J].
Wu, Fan ;
Zhao, Su ;
Yu, Bin ;
Chen, Yan-Mei ;
Wang, Wen ;
Song, Zhi-Gang ;
Hu, Yi ;
Tao, Zhao-Wu ;
Tian, Jun-Hua ;
Pei, Yuan-Yuan ;
Yuan, Ming-Li ;
Zhang, Yu-Ling ;
Dai, Fa-Hui ;
Liu, Yi ;
Wang, Qi-Min ;
Zheng, Jiao-Jiao ;
Xu, Lin ;
Holmes, Edward C. ;
Zhang, Yong-Zhen .
NATURE, 2020, 579 (7798) :265-+
[17]  
Zainol Rashid Z, 2020, MALAYS J PATHOL, V42, P13
[18]  
Zhu N, 2020, NEW ENGL J MED, V382, P727, DOI [10.1172/JCI89857, 10.1056/NEJMoa2001017]