Potential errors in the application of mixture theory to multifrequency bioelectrical impedance analysis

被引:37
作者
Ward, LC [1 ]
Elia, M
Cornish, BH
机构
[1] Univ Queensland, Dept Biochem, Brisbane, Qld 4072, Australia
[2] MRC, Dunn Clin Nutr Ctr, Cambridge CB2 1QL, England
[3] Queensland Univ Technol, Ctr Hlth & Med Phys, Brisbane, Qld, Australia
关键词
mixture theory; errors; bioelectrical impedance analysis; multiple-frequency bioelectrical impedance analysis;
D O I
10.1088/0967-3334/19/1/005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Potential errors in the application of mixture theory to the analysis of multiple-frequency bioelectrical impedance data for the determination of body fluid volumes are assessed. Potential sources of error include: conductive length; tissue fluid resistivity; body density; weight and technical errors of measurement. Inclusion of inaccurate estimates of body density and weight introduce errors of typically < +/-3% but incorrect assumptions regarding conductive length or fluid resistivities may each incur errors of up to 20%.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 23 条
  • [1] APPLIED POTENTIAL TOMOGRAPHY
    BARBER, DC
    BROWN, BH
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09): : 723 - 733
  • [2] BLAGOJEVIC N, 1990, Australasian Physical and Engineering Sciences in Medicine, V13, P110
  • [3] Cornish BH, 1996, EUR J CLIN NUTR, V50, P159
  • [4] IMPROVED PREDICTION OF EXTRACELLULAR AND TOTAL-BODY WATER USING IMPEDANCE LOCI GENERATED BY MULTIPLE FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS
    CORNISH, BH
    THOMAS, BJ
    WARD, LC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03) : 337 - 346
  • [5] Predicting body cell mass with bioimpedance by using theoretical methods: A technological review
    DeLorenzo, A
    Andreoli, A
    Matthie, J
    Withers, P
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) : 1542 - 1558
  • [6] Multi-frequency bioelectrical impedance: A comparison between the Cole-Cole modelling and Hanai equations with the classical impedance index approach
    Deurenberg, P
    Andreoli, A
    deLorenzo, A
    [J]. ANNALS OF HUMAN BIOLOGY, 1996, 23 (01) : 31 - 40
  • [7] FULLER NJ, 1989, EUR J CLIN NUTR, V43, P779
  • [8] SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST
    GEDDES, LA
    BAKER, LE
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03): : 271 - &
  • [9] Hanai T., 1968, EMULSION SCI
  • [10] EVALUATION OF MULTIFREQUENCY BIOIMPEDANCE ANALYSIS FOR THE ASSESSMENT OF EXTRACELLULAR AND TOTAL-BODY WATER IN SURGICAL PATIENTS
    HANNAN, WJ
    COWEN, SJ
    FEARON, KCH
    PLESTER, CE
    FALCONER, JS
    RICHARDSON, RA
    [J]. CLINICAL SCIENCE, 1994, 86 (04) : 479 - 485