Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs

被引:37
作者
Alhammadi, Maged Sultan [1 ]
Al-mashraqi, Abeer Abdulkareem [2 ]
Alnami, Rayid Hussain [3 ]
Ashqar, Nawaf Mohammad [3 ]
Alamir, Omar Hassan [3 ]
Halboub, Esam [2 ,4 ]
Reda, Rodolfo [5 ]
Testarelli, Luca [5 ]
Patil, Shankargouda [6 ]
机构
[1] Jazan Univ, Orthodont & Dentofacial Orthoped, Coll Dent, Dept Prevent Dent Sci, Jazan 45142, Saudi Arabia
[2] Jazan Univ, Dept Maxillofacial Surg & Diagnost Sci, Coll Dent, Jazan 45142, Saudi Arabia
[3] Jazan Univ, Coll Dent, Internship Program, Jazan 45142, Saudi Arabia
[4] Sanaa Univ, Fac Dent, Dept Oral Med Oral Pathol & Oral Radiol, Sanaa 1247, Yemen
[5] Sapienza Univ Rome, Dept Oral & Maxillofacial Sci, I-00185 Rome, Italy
[6] Jazan Univ, Div Oral Pathol, Dept Maxillofacial Surg & Diagnost Sci, Coll Dent, Jazan 45142, Saudi Arabia
关键词
cone beam computed tomography; facial photographs; standardized photograph; wrapped photographs; SOFT-TISSUE ANALYSIS; RELIABILITY;
D O I
10.3390/diagnostics11050757
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18-30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland-Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.
引用
收藏
页数:11
相关论文
共 16 条
[1]   Evaluating the accuracy of facial models obtained from volume wrapping: 2D images on CBCT versus 3D on CBCT [J].
Almulla, Soghyia ;
Premjani, Pratik ;
Vaid, Nikhilesh R. ;
Fadia, Dhaval F. ;
Ferguson, Donald J. .
SEMINARS IN ORTHODONTICS, 2018, 24 (04) :443-450
[2]   Repeatability Study of Angular and Linear Measurements on Facial Morphology Analysis by Means of Stereophotogrammetry [J].
Andrade, Lilian Mendes ;
Bettoni Rodrigues da Silva, Ana Maria ;
Magri, Lais Valencise ;
Moreira Rodrigues da Silva, Marco Antonio .
JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (04) :1107-1111
[3]   Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging [J].
Ayaz, Irem ;
Shaheen, Eman ;
Aly, Medhat ;
Shujaat, Sohaib ;
Gallo, Giulia ;
Coucke, Wim ;
Politis, Constantinus ;
Jacobs, Reinhilde .
IMAGING SCIENCE IN DENTISTRY, 2020, 50 (01) :15-22
[4]   Accuracy and reliability of 3D stereophotogrammetry: A comparison to direct anthropometry and 2D photogrammetry [J].
Dindaroglu, Furkan ;
Kutlu, Pinar ;
Duran, Gokhan Serhat ;
Gorgulu, Serkan ;
Aslan, Erhan .
ANGLE ORTHODONTIST, 2016, 86 (03) :487-494
[5]   History of imaging in orthodontics from Broadbent to cone-beam computed tomography [J].
Hans, Mark G. ;
Palomo, J. Martin ;
Valiathan, Manish .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 148 (06) :914-921
[6]   Accuracy and head positioning effects on measurements of anterior tooth length using 3-dimensional and conventional dental panoramic radiography [J].
Kitai, Noriyuki ;
Murabayashi, Manabu ;
Sugimoto, Hiroshi ;
Fujiwara, Atsushi ;
Tome, Wakako ;
Katsumata, Akitoshi .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (03) :607-615
[7]   Superimposition of a cone beam computed tomography (CBCT) scan and a photograph: A dental technique [J].
Lee, Soo Young ;
Kim, Heechul ;
Lee, Doyun ;
Park, Chan .
JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02) :212-215
[8]   Accuracy of measurements of mandibular anatomy in cone beam computed tomography images [J].
Ludlow, John B. ;
Laster, William Stewart ;
See, Meit ;
Bailey, L'Tanya J. ;
Garland Hershey, H. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (04) :534-542
[9]   A 3-DIMENSIONAL SOFT-TISSUE ANALYSIS OF 16 SKELETAL CLASS-III PATIENTS FOLLOWING BIMAXILLARY SURGERY [J].
MCCANCE, AM ;
MOSS, JP ;
WRIGHT, WR ;
LINNEY, AD ;
JAMES, DR .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1992, 30 (04) :221-232
[10]  
Mehta P, 2017, J CLIN DIAGN RES, V11, pZC60, DOI 10.7860/JCDR/2017/25042.10075