Performance of Coating Materials on Planar Electromagnetic Sensing Array to Detect Water Contamination

被引:16
|
作者
Azmi, Aizat [1 ]
Azman, Ahmad Amsyar [1 ]
Kaman, Khairell Khazin [1 ]
Ibrahim, Sallehuddin [1 ]
Mukhopadhyay, Subhas Chandra [2 ]
Nawawi, Sophan Wahyudi [1 ]
Yunus, Mohd Amri Md [1 ]
机构
[1] Univ Teknol Malaysia, Skudai 81310, Malaysia
[2] Macquarie Univ, Mech Elect Engn, Sydney, NSW 2109, Australia
关键词
Planar electromagnetic sensor array; water contaminants; membrane; nitrate; phosphate; nickel; SENSOR ARRAY; NITRATE; CHROMATOGRAPHY; WIRELESS;
D O I
10.1109/JSEN.2017.2720701
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper looked into the electrical properties of contaminants via planar electromagnetic sensing array (PESA), which had been coated with various types of coaters, namely, N-Methyl-2-pyrrolidone-based membrane and acrylic. Hence, the performance of the coaters had been evaluated based on the minimal difference of estimated results, which was later compared with an Agilent 85070 dielectric probe instrument. Three samples were selected for this paper, namely, nitrate, phosphate, and nickel solutions. These samples were prepared based on varied concentration levels, including 5, 25, 75, and 100 ppm. Besides, the theory for the sensor equivalent to circuit described the calculations to determine the aspects of permittivity and conductivity of the water samples. The results demonstrated that both coaters successfully estimated the electrical properties of the contaminants. The relative permittivity of all samples using the PESA coated with membrane displayed similar trends for the dielectric probe, but a slight variance was present for the PESA coated with acrylic. In fact, the relative permittivity of the nitrate sample ranged from 65 to 78 when the estimation was made using PESA coated with membrane, whereas the acrylic coater demonstrated that the relative permittivity data varied from 0.198 to 41.100. Hence, the acrylic coater failed in precision, thus inappropriate for relative permittivity estimation. Nonetheless, both coaters shared similar pattern for conductivity even with varied concentrations. However, the conductivity increased as the sample concentration increased. As such, this paper concludes that the PESA coated with membrane exhibited better performance compared with acrylic in estimating electrical properties.
引用
收藏
页码:5244 / 5251
页数:8
相关论文
共 15 条
  • [1] Metamaterial Inspired Multiband Planar Array to Detect Glyphosate in Water by Real-Time Electromagnetic Wave Sensor
    San Roman Castillo, Ebert
    Fernandez, Elizabeth
    Castillo Aranibar, Patricia
    Segovia Vargas, Daniel
    2018 IEEE MTT-S LATIN AMERICA MICROWAVE CONFERENCE (LAMC 2018), 2018,
  • [2] Detect and Pointing Algorithm's Performance for a Planar Smart Antenna Array: A Review
    Varum, Tiago
    Matos, Joao N.
    Pinho, Pedro
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2015, 30 (08): : 824 - 837
  • [3] Novel Planar Electromagnetic Sensors for Detection of Nitrates and Contamination in Natural Water Sources
    Yunus, Mohd Amri Md.
    Mukhopadhyay, Subhas Chandra
    IEEE SENSORS JOURNAL, 2011, 11 (06) : 1440 - 1447
  • [4] Development of planar electromagnetic sensor array for nitrate and sulphate detection in natural water sources
    Nor, Alif Syarafi Mohamad
    Yunus, Mohd Amri Md
    Nawawi, Sophan Wahyudi
    Ibrahim, Sallehuddin
    Rahmat, Mohd Fua'ad
    SENSOR REVIEW, 2015, 35 (01) : 106 - 115
  • [5] Planar Electromagnetic Sensor Based Estimation of Nitrate Contamination in Water Sources Using Independent Component Analysis
    Yunus, Mohd Amri Md
    Mukhopadhyay, Subhas Chandra
    Ibrahim, Sallehuddin
    IEEE SENSORS JOURNAL, 2012, 12 (06) : 2024 - 2034
  • [6] Development of a Low Cost System for Nitrate and Contamination Detections in Natural Water Supply based on a Planar Electromagnetic Sensor
    Yunus, Mohd Amri Md
    Mendez, Gerard Rudolph
    Mukhopadhyay, Subhas Chandra
    2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 1557 - 1562
  • [7] A high-performance sub-THz planar antenna array for THz sensing and imaging applications
    Zubair, Muhammad
    Jabbar, Abdul
    Tahir, Farooq A.
    Kazim, Jalil ur Rehman
    Rehman, Masood Ur
    Imran, Muhammad
    Liu, Bo
    Abbasi, Qammer H.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] Nitrate and Sulfate Estimations in Water Sources Using a Planar Electromagnetic Sensor Array and Artificial Neural Network Method
    Nor, Alif Syarafi Mohamad
    Faramarzi, Mahdi
    Yunus, Mohd Amri Md
    Ibrahim, Sallehuddin
    IEEE SENSORS JOURNAL, 2015, 15 (01) : 497 - 504
  • [9] Towards Sensing Performance of Metal Clad Planar Waveguide Sensor with Transition Metal Dichalcogenide Materials
    Maurya, Rajiv
    Mishra, Vivekanand
    Singh, Vivek
    SILICON, 2022, 14 (16) : 10919 - 10929
  • [10] Towards Sensing Performance of Metal Clad Planar Waveguide Sensor with Transition Metal Dichalcogenide Materials
    Rajiv Maurya
    Vivekanand Mishra
    Vivek Singh
    Silicon, 2022, 14 : 10919 - 10929