Talker intelligibility differences in cochlear implant listeners

被引:11
作者
Green, Tim [1 ]
Katiri, Sotira [1 ]
Faulkner, Andrew [1 ]
Rosen, Stuart [1 ]
机构
[1] UCL, Dept Phonet & Linguist, London NW1 2HE, England
关键词
D O I
10.1121/1.2720938
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
People vary in the intelligibility of their speech. This study investigated whether across-talker intelligibility differences observed in normally-hearing listeners are also found in cochlear implant (CI) users. Speech perception for male, female, and child pairs of talkers differing in intelligibility was assessed with actual and, simulated Cl processing and in normal hearing. While overall speech recognition was, as expected, poorer for Cl users, differences in intelligibility across talkers were consistent across all listener groups. This suggests that the primary determinants of intelligibility differences are preserved in the CI-processed signal, though no single critical acoustic property could be identified. (c) 2007 Acoustical Society of America.
引用
收藏
页码:EL223 / EL229
页数:7
相关论文
共 24 条
[1]   The SUS test: A method for the assessment of text-to-speech synthesis intelligibility using Semantically Unpredictable Sentences [J].
Benoit, C ;
Grice, M ;
Hazan, V .
SPEECH COMMUNICATION, 1996, 18 (04) :381-392
[2]   A NOTE ON THE ACOUSTIC-PHONETIC CHARACTERISTICS OF INADVERTENTLY CLEAR SPEECH [J].
BOND, ZS ;
MOORE, TJ .
SPEECH COMMUNICATION, 1994, 14 (04) :325-337
[3]   Intelligibility of normal speech .1. Global and fine-grained acoustic-phonetic talker characteristics [J].
Bradlow, AR ;
Torretta, GM ;
Pisoni, DB .
SPEECH COMMUNICATION, 1996, 20 (3-4) :255-272
[4]  
Collett D., 2003, C&H TEXT STAT SCI, V2nd
[5]   The right information may matter more than frequency-place alignment: Simulations of frequency-aligned and upward shifting cochlear implant processors for a shallow electrode array insertion [J].
Faulkner, A ;
Rosen, S ;
Norman, C .
EAR AND HEARING, 2006, 27 (02) :139-152
[6]   Vowel intelligibility in clear and conversational speech for normal-hearing and hearing-impaired listeners [J].
Ferguson, SH ;
Kewley-Port, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (01) :259-271
[7]   Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants [J].
Friesen, LM ;
Shannon, RV ;
Baskent, D ;
Wang, X .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 110 (02) :1150-1163
[8]   Enhancing temporal cues to voice pitch in continuous interleaved sampling cochlear implants [J].
Green, T ;
Faulkner, A ;
Rosen, S .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (04) :2298-2310
[9]   Spectral and temporal cues to pitch in noise-excited vocoder simulations of continuous-interleaved-sampling cochlear implants [J].
Green, T ;
Faulkner, A ;
Rosen, S .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (05) :2155-2164
[10]   A COCHLEAR FREQUENCY-POSITION FUNCTION FOR SEVERAL SPECIES - 29 YEARS LATER [J].
GREENWOOD, DD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (06) :2592-2605