EVALUATION OF POSITIONING ACCURACY OF FOUR DIFFERENT IMMOBILIZATIONS USING CONE-BEAM CT IN RADIOTHERAPY OF NON-SMALL-CELL LUNG CANCER

被引:11
作者
Wang, Jin [2 ]
Zhong, Renming [3 ]
Bai, Sen [3 ]
Lu, You [2 ]
Xu, Qingfeng [3 ]
Zhou, Xiao-Juan [2 ]
Xu, Feng [1 ]
机构
[1] Sichuan Univ, Div Abdominal Tumor, Ctr Canc, W China Hosp, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, Div Thorac Tumor, Ctr Canc, W China Hosp, Chengdu 610041, Peoples R China
[3] Sichuan Univ, Div Radiat Phys, Ctr Canc, W China Hosp, Chengdu 610041, Peoples R China
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 77卷 / 04期
关键词
Non-small-cell lung cancer; Cone-beam CT; Immobilization; Positioning error; Margin; INSPIRATION BREATH-HOLD; IMAGE-GUIDED RADIOTHERAPY; SET-UP ERRORS; COMPUTED-TOMOGRAPHY; STEREOTACTIC RADIOTHERAPY; CONFORMAL RADIOTHERAPY; RESPIRATORY MOVEMENT; RADIATION-THERAPY; TUMOR POSITION; CONTROL ABC;
D O I
10.1016/j.ijrobp.2009.09.049
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the positioning accuracy of four different immobilizations by use of cone-beam computed tomography guidance for radiotherapy of non-small-cell lung cancer (NSCLC). Methods and Materials: Sixty-seven patients with NSCLC received conventional or stereotactic body radiotherapy. Of these, 30 were immobilized with a thermoplastic frame (TF), 16 with a thermoplastic frame and active breathing control (TF-ABC), 7 with a stereotactic body frame (SBF), and 14 with a stereotactic body frame and active breathing control (SBF-ABC). Cone-beam computed tomography scans at initial setup and after correction were registered to planning computed tomography. The positional errors in the left-to-right, superior-inferior, and anterior-posterior directions were analyzed. The planning target volume margins were calculated. Results: The precorrection systematic and random errors ranged from 1.9 to 4.2 mm for TF, 1.9 to 4.3 mm for SBF, 1.2 to 5.8 mm for TF-ABC, and 2.3 to 3.9 mm for SBF-ABC. The postcorrection systematic and random errors ranged from 0.3 to 1.9 mm for the four hnmobilizations. The planning target volume margins (conventional vs. stereotactic body radiotherapy) were 15.6 vs. 13.9 mm (TF), 14.9 vs. 14.8 mm (TF-ABC), 14.4 vs. 13.4 mm (SEW), and 9.9 vs. 9.4 mm (SBF-ABC) before correction and 7.3 vs. 6.9 mm (TF), 4.0 vs. 3.8 mm (TF-ABC), 7.5 vs. 7.1 mm (SBF), and 4.5 vs. 4.2 mm (SBF-ABC) after correction. Conclusions: The positioning accuracies of SBF and TF were similar. Active breathing control increased positioning error but reduced internal margin. Cone-beam computed tomography online correction improved the positioning accuracy of NSCLC patients. (C) 2010 Elsevier Inc.
引用
收藏
页码:1274 / 1281
页数:8
相关论文
共 50 条
[31]   INITIAL DETERMINATION OF SETUP ERRORS USING DAILY CONE-BEAM CT REDUCES SUBSEQUENT VARIATION OVER A LUNG CANCER RADIOTHERAPY TREATMENT COURSE [J].
Yom, Sue S. ;
Chen, Josephine ;
Aubin, Michele ;
Morin, Olivier ;
Graff, Pierre ;
Descovich, Martina ;
Pouliot, Jean .
JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) :S830-S830
[32]   Cone-Beam-CT Guided Adaptive Radiotherapy for Locally Advanced Non-small Cell Lung Cancer Enables Quality Assurance and Superior Sparing of Healthy Lung [J].
Hoegen, Philipp ;
Lang, Clemens ;
Akbaba, Sati ;
Haering, Peter ;
Splinter, Mona ;
Miltner, Annette ;
Bachmann, Marion ;
Stahl-Arnsberger, Christiane ;
Brechter, Thomas ;
El Shafie, Rami A. ;
Weykamp, Fabian ;
Koenig, Laila ;
Debus, Juergen ;
Hoerner-Rieber, Juliane .
FRONTIERS IN ONCOLOGY, 2020, 10
[33]   Radiotherapy dose calculation on KV cone-beam CT image for lung tumor using the CIRS calibration [J].
Ma, Changsheng ;
Cao, Jianping ;
Yin, Yong ;
Zhu, Jian .
THORACIC CANCER, 2014, 5 (01) :68-73
[34]   Comparison of primary target volumes delineated on four-dimensional CT and 18 F-FDG PET/CT of non-small-cell lung cancer [J].
Duan, Yi-Li ;
Li, Jian-Bin ;
Zhang, Ying-Jie ;
Wang, Wei ;
Li, Feng-Xiang ;
Sun, Xiao-Rong ;
Guo, Yan-Luan ;
Shang, Dong-Ping .
RADIATION ONCOLOGY, 2014, 9 :1-8
[35]   Evaluation of three presets for four-dimensional cone beam CT in lung radiotherapy verification by visual grading analysis [J].
Kember, Sally A. ;
Hansen, Vibeke N. ;
Fast, Martin F. ;
Nill, Simeon ;
McDonald, Fiona ;
Ahmed, Merina ;
Thomas, Karen ;
McNair, Helen A. .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
[36]   The use of proton-beam therapy in the treatment of non-small-cell lung cancer [J].
Oshiro, Yoshiko ;
Sakurai, Hideyuki .
EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (02) :239-245
[37]   Analysis of Intra-Thoracic Anatomical Changes Observed in Clinical Workflow of Cone-Beam CT Guided Radiotherapy for Lung Cancer [J].
Belderbos, Jose ;
Rossi, Maddalena ;
Kwint, Margriet ;
Beek, Suzanne ;
Sonke, Jan-Jakob .
JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) :S417-S417
[38]   A novel evaluation model of image registration for cone-beam computed tomography guided lung cancer radiotherapy [J].
Liu, Yimei ;
Chen, Meining ;
Fang, Jianlan ;
Xiao, Liangjie ;
Liu, Songran ;
Li, Qiwen ;
Qiu, Bo ;
Huang, Runda ;
Zhang, Jun ;
Peng, Yinglin .
THORACIC CANCER, 2024, 15 (17) :1333-1342
[39]   Accuracy of Image Guidance Using Free-Breathing Cone-Beam Computed Tomography for Stereotactic Lung Radiotherapy [J].
Kamomae, Takeshi ;
Monzen, Hajime ;
Nakayama, Shinichi ;
Mizote, Rika ;
Oonishi, Yuuichi ;
Kaneshige, Soichiro ;
Sakamoto, Takashi .
PLOS ONE, 2015, 10 (05)
[40]   PET CT THRESHOLDS FOR RADIOTHERAPY TARGET DEFINITION IN NON-SMALL-CELL LUNG CANCER: HOW CLOSE ARE WE TO THE PATHOLOGIC FINDINGS? [J].
Wu, Kailiang ;
Ung, Yee C. ;
Hornby, Jennifer ;
Freeman, Marc ;
Hwang, David ;
Tsao, Ming S. ;
Dahele, Max ;
Darling, Gail ;
Maziak, Donna E. ;
Tirona, Romeo ;
Mah, Kathy ;
Wong, C. Shun .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03) :699-706