EVALUATION OF POSITIONING ACCURACY OF FOUR DIFFERENT IMMOBILIZATIONS USING CONE-BEAM CT IN RADIOTHERAPY OF NON-SMALL-CELL LUNG CANCER

被引:11
|
作者
Wang, Jin [2 ]
Zhong, Renming [3 ]
Bai, Sen [3 ]
Lu, You [2 ]
Xu, Qingfeng [3 ]
Zhou, Xiao-Juan [2 ]
Xu, Feng [1 ]
机构
[1] Sichuan Univ, Div Abdominal Tumor, Ctr Canc, W China Hosp, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, Div Thorac Tumor, Ctr Canc, W China Hosp, Chengdu 610041, Peoples R China
[3] Sichuan Univ, Div Radiat Phys, Ctr Canc, W China Hosp, Chengdu 610041, Peoples R China
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 77卷 / 04期
关键词
Non-small-cell lung cancer; Cone-beam CT; Immobilization; Positioning error; Margin; INSPIRATION BREATH-HOLD; IMAGE-GUIDED RADIOTHERAPY; SET-UP ERRORS; COMPUTED-TOMOGRAPHY; STEREOTACTIC RADIOTHERAPY; CONFORMAL RADIOTHERAPY; RESPIRATORY MOVEMENT; RADIATION-THERAPY; TUMOR POSITION; CONTROL ABC;
D O I
10.1016/j.ijrobp.2009.09.049
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the positioning accuracy of four different immobilizations by use of cone-beam computed tomography guidance for radiotherapy of non-small-cell lung cancer (NSCLC). Methods and Materials: Sixty-seven patients with NSCLC received conventional or stereotactic body radiotherapy. Of these, 30 were immobilized with a thermoplastic frame (TF), 16 with a thermoplastic frame and active breathing control (TF-ABC), 7 with a stereotactic body frame (SBF), and 14 with a stereotactic body frame and active breathing control (SBF-ABC). Cone-beam computed tomography scans at initial setup and after correction were registered to planning computed tomography. The positional errors in the left-to-right, superior-inferior, and anterior-posterior directions were analyzed. The planning target volume margins were calculated. Results: The precorrection systematic and random errors ranged from 1.9 to 4.2 mm for TF, 1.9 to 4.3 mm for SBF, 1.2 to 5.8 mm for TF-ABC, and 2.3 to 3.9 mm for SBF-ABC. The postcorrection systematic and random errors ranged from 0.3 to 1.9 mm for the four hnmobilizations. The planning target volume margins (conventional vs. stereotactic body radiotherapy) were 15.6 vs. 13.9 mm (TF), 14.9 vs. 14.8 mm (TF-ABC), 14.4 vs. 13.4 mm (SEW), and 9.9 vs. 9.4 mm (SBF-ABC) before correction and 7.3 vs. 6.9 mm (TF), 4.0 vs. 3.8 mm (TF-ABC), 7.5 vs. 7.1 mm (SBF), and 4.5 vs. 4.2 mm (SBF-ABC) after correction. Conclusions: The positioning accuracies of SBF and TF were similar. Active breathing control increased positioning error but reduced internal margin. Cone-beam computed tomography online correction improved the positioning accuracy of NSCLC patients. (C) 2010 Elsevier Inc.
引用
收藏
页码:1274 / 1281
页数:8
相关论文
共 50 条
  • [11] Clinical evaluation of proton radiotherapy for non-small-cell lung cancer
    Shioyama, Y
    Tokuuye, K
    Okumura, T
    Kagei, K
    Sugahara, S
    Ohara, K
    Akine, Y
    Ishikawa, S
    Satoh, H
    Sekizawa, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 7 - 13
  • [12] Accumulation of the delivered dose based on cone-beam CT and deformable image registration for non-small cell lung cancer treated with hypofractionated radiotherapy
    Bin Wang
    Da Quan Wang
    Mao Sheng Lin
    Shi Pei Lu
    Jun Zhang
    Li Chen
    Qi Wen Li
    Zhang Kai Cheng
    Fang Jie Liu
    Jin Yu Guo
    Hui Liu
    Bo Qiu
    BMC Cancer, 20
  • [13] TUMOR LOCALIZATION USING CONE-BEAM CT REDUCES SETUP MARGINS IN CONVENTIONALLY FRACTIONATED RADIOTHERAPY FOR LUNG TUMORS
    Yeung, Anamaria R.
    Li, Jonathan G.
    Shi, Wenyin
    Newlin, Heather E.
    Chvetsov, Alexei
    Liu, Chihray
    Palta, Jatinder R.
    Olivier, Kenneth
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (04): : 1100 - 1107
  • [14] Shading correction for cone-beam CT in radiotherapy: Validation of dose calculation accuracy using clinical images
    Marchant, T. E.
    Joshi, K. D.
    Moore, C. J.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [15] Effect of image-guided hypofractionated stereotactic radiotherapy on peripheral non-small-cell lung cancer
    Wang, Shu-wen
    Ren, Juan
    Yan, Yan-li
    Xue, Chao-fan
    Tan, Li
    Ma, Xiao-wei
    ONCOTARGETS AND THERAPY, 2016, 9 : 4993 - 5003
  • [16] Current landscape of palliative radiotherapy for non-small-cell lung cancer
    Jumeau, Raphael
    Vilotte, Florent
    Durham, Andre-Dante
    Ozsahin, Esat-Mahmut
    TRANSLATIONAL LUNG CANCER RESEARCH, 2019, 8 : S192 - S201
  • [17] A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer
    Santoro, J. P.
    McNamara, J.
    Yorke, E.
    Pham, H.
    Rimner, A.
    Rosenzweig, K. E.
    Mageras, G. S.
    MEDICAL PHYSICS, 2012, 39 (10) : 5825 - 5834
  • [18] Metabolic imaging in non-small-cell lung cancer radiotherapy
    Geets, X.
    Sterpin, E.
    Wanet, M.
    Di Perri, D.
    Lee, J.
    CANCER RADIOTHERAPIE, 2014, 18 (5-6): : 402 - 405
  • [19] Longitudinal radiomics of cone-beam CT images from non-small cell lung cancer patients: Evaluation of the added prognostic value for overall survival and locoregional recurrence
    van Timmeren, Janna E.
    van Elmpt, Wouter
    Leijenaar, Ralph T. H.
    Reymen, Bart
    Monshouwer, Rene
    Bussink, Johan
    Paelinck, Leen
    Bogaert, Evelien
    De Wagter, Carlos
    Elhaseen, Elamin
    Lievens, Yolande
    Hansen, Olfred
    Brink, Carsten
    Lambin, Philippe
    RADIOTHERAPY AND ONCOLOGY, 2019, 136 : 78 - 85
  • [20] Radiotherapy and targeted therapies in non-small-cell lung cancer