Complications after transcatheter closure of patent ductus arteriosus

被引:54
作者
Jang, Gi Young
Son, Chang Sung
Lee, Joo Won
Lee, Jae Young
Kim, Soo Jin
机构
[1] Univ Korea Hosp, Dept Pediat, Seoul, South Korea
[2] Sejong Hosp, Dept Pediat, Puchon, South Korea
关键词
patent ductus arteriosus; catheterization; complications;
D O I
10.3346/jkms.2007.22.3.484
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the short- and mid-term results and complications ensuing the transcatheter closure of patent ductus arteriosus (PDA). Between October 1999 and December 2005, 117 patients (34 males and 83 females) underwent attempted percutaneous closure of PDA with a minimum diameter of more than 3 mm. Follow-up evaluations were conducted at 1 day and 1, 3, 6, 12 months after the performance of the transcatheter closure. The median age of patients at catheterization was 11 yr (range, 0.6 to 68 yr), median weight was 30 kg (range, 6 to 74 kg), and the median diameter of PDA was 4 mm (range, 3 to 8 mm). This procedure was conducted successfully in 114 patients (97.4%), using different devices. Major complications were detected in 4 patients (3.4%); significant hemolysis (2), infective endocarditis (1), failed procedure due to embolization (1). Minor complications occurred in 6 patients (5.1 %); mild narrowing of the descending aorta (2) and mild encroachment on the origin of the left pulmonary artery (4). Although the transcatheter closure of PDA may be considered to be effective, several complications, including hemolysis, embolization, infective endocarditis, and the narrowing of adjacent vessels may occur in certain cases.
引用
收藏
页码:484 / 490
页数:7
相关论文
共 26 条
[1]   The efficacy and safety of the Amplatzer ductal occluder in young children and infants [J].
Al-Ata, J ;
Arfi, AM ;
Hussain, A ;
Kouatli, AA ;
Jalal, MO .
CARDIOLOGY IN THE YOUNG, 2005, 15 (03) :279-285
[2]   The Amplatzer duct occluder: Experience in 209 patients [J].
Bilkis, AA ;
Alwi, M ;
Hasri, S ;
Haifa, AL ;
Geetha, K ;
Rehman, MA ;
Hasanah, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) :258-261
[3]  
Celiker A, 1997, EUR HEART J, V18, P450
[4]   First closure of a large patent ductus arteriosus in an infant with an angulated nitinol plug [J].
Ewert, P ;
Kretschmar, O ;
Nuernberg, JH ;
Nagdyman, N ;
Lange, PE .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (01) :88-91
[5]  
Faella HJ, 2000, CATHETER CARDIO INTE, V51, P50, DOI 10.1002/1522-726X(200009)51:1<50::AID-CCD11>3.0.CO
[6]  
2-6
[7]   Systemic allergic reaction to the percutaneous patent foramen ovale occluder [J].
Fukahara, K ;
Minami, K ;
Reiss, N ;
Fassbender, D ;
Koerfer, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (01) :213-214
[8]  
Galal O, 1997, EUR HEART J, V18, P625
[9]   Catheter closure of ductus arteriosus in adolescents and adults: What to use? [J].
Hijazi, ZM .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (04) :519-520
[10]   Transcatheter closure of large patent ductus arteriosus (>=4 mm) with multiple Gianturco coils: Immediate and mid-term results [J].
Hijazi, ZM ;
Geggel, RL .
HEART, 1996, 76 (06) :536-540