Mathematical Modeling of Rotary Blood Pumps in a Pulsatile In Vitro Flow Environment

被引:10
作者
Pirbodaghi, Tohid [1 ]
机构
[1] Univ Bern, Murtenstr 50, CH-3010 Bern, Switzerland
关键词
Rotary blood pumps; In-vitro study; Dynamic identification; HEAD ESTIMATION; PRESSURE-HEAD; MODULATION;
D O I
10.1111/aor.12860
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nowadays, sacrificing animals to develop medical devices and receive regulatory approval has become more common, which increases ethical concerns. Although in vivo tests are necessary for development and evaluation of new devices, nonetheless, with appropriate in vitro setups and mathematical models, a part of the validation process can be performed using these models to reduce the number of sacrificed animals. The main aim of this study is to present a mathematical model simulating the hydrodynamic function of a rotary blood pump (RBP) in a pulsatile in vitro flow environment. This model relates the pressure head of the RBP to the flow rate, rotational speed, and time derivatives of flow rate and rotational speed. To identify the model parameters, an in vitro setup was constructed consisting of a piston pump, a compliance chamber, a throttle, a buffer reservoir, and the CentriMag RBP. A 40% glycerin-water mixture as a blood analog fluid and deionized water were used in the hydraulic circuit to investigate the effect of viscosity and density of the working fluid on the model parameters. First, model variables were physically measured and digitally acquired. Second, an identification algorithm based on regression analysis was used to derive the model parameters. Third, the completed model was validated with a totally different set of in vitro data. The model is usable for both mathematical simulations of the interaction between the pump and heart and indirect pressure measurement in a clinical context.
引用
收藏
页码:710 / 716
页数:7
相关论文
共 34 条
  • [31] Extended storage of whole blood before the preparation of blood components: in vitro effects on red blood cells in Erythro-Sol environment
    Gulliksson, H.
    Vesterinen, M.
    Payrat, J.-M.
    Mayaudon, V.
    VOX SANGUINIS, 2009, 96 (03) : 199 - 205
  • [32] Advanced blood flow assessment in Zebrafish via experimental digital particle image velocimetry and computational fluid dynamics modeling
    Salman, Huseyin Enes
    Yalcin, Huseyin Cagatay
    MICRON, 2020, 130
  • [33] Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: Results in hemolysis tests
    Takiura, K
    Masuzawa, T
    Endo, S
    Wakisaka, Y
    Tatsumi, E
    Taenaka, Y
    Takano, H
    Yamane, T
    Nishida, M
    Asztalos, B
    Konishi, Y
    Miyazoe, Y
    Ito, K
    ARTIFICIAL ORGANS, 1998, 22 (05) : 393 - 398
  • [34] Effect of transient warming of red blood cells for up to 24 h: in vitro characteristics in CPD/saline-adenine-glucose-mannitol environment
    Gulliksson, H.
    Nordahl-Kallman, A-S.
    VOX SANGUINIS, 2014, 106 (01) : 61 - 67