Sol-gel coated ion sources for liquid chromatography-direct electron ionization mass spectrometry

被引:13
作者
Riboni, Nicolo [1 ]
Magrini, Laura [2 ]
Bianchi, Federica [1 ]
Careri, Maria [1 ]
Cappiello, Achille [2 ]
机构
[1] Univ Parma, Dipartimento Sci Chim Vita & Sostenibil Ambiental, Parco Area Sci 17-A, I-43124 Parma, Italy
[2] Univ Urbino Carlo Bo, Dipartimento Sci Pure & Appl, Piazza Rinascimento 6, I-61029 Urbino, Italy
关键词
Ion source; Liquid chromatography-direct electron ionization mass spectrometry; Coatings; Sol-gel; DIRECT-EI INTERFACE; PHASE MICROEXTRACTION; STAINLESS-STEEL; COATINGS; MS; WATER; PERFORMANCE;
D O I
10.1016/j.aca.2017.04.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Advances in interfacing liquid chromatography and electron ionization mass spectrometry are presented. New ion source coatings synthesized by sol-gel technology were developed and tested as vaporization surfaces in terms of peak intensity, peak width and peak delay for the liquid chromatography-direct electron ionization mass spectrometry (Direct-EI) determination of environmental pollutants like polycyclic aromatic hydrocarbons and steroids. Silica-, titania-, and zirconia-based coatings were sprayed inside the stainless steel ion source and characterized in terms of thermal stability, film thickness and morphology. Negligible weight losses until 350-400 degrees C were observed for all the materials, with coating thicknesses in the 6 (+/- 1)-11 (+/- 2) mm range for optimal ionization process. The best performances in terms of both peak intensity and peak width were obtained by using the silica-based coating: the detection of the investigated compounds was feasible at low ng mu l(-1) levels with a good precision (RSD < 9% for polycyclic aromatic hydrocarbons and < 11% for hormones). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [41] Characterization of polymethoxylated flavones in Fructus aurantii by off-line two-dimensional liquid chromatography/electrospray ionization-ion trap mass spectrometry
    Zhou, Da-Yong
    Xu, Qing
    Xue, Xing-Ya
    Zhang, Fei-Fang
    Liang, Xin-Miao
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (02) : 207 - 213
  • [42] Implementation of an enclosed ionization interface for the analysis of liquid sample streams with direct analysis in real time mass spectrometry
    Kloth, Ricarda
    Khanipour, Peyman
    Mayrhofer, Karl J. J.
    Katsounaros, Ioannis
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (13)
  • [43] Simultaneous analysis of analgesics and their major metabolites by liquid chromatography-electrospray ion trap mass spectrometry
    Chen, Xueguo
    Song, Ming
    Zhu, Yu
    Wu, Di
    Xu, Yingjian
    ANALYTICAL METHODS, 2013, 5 (18) : 4764 - 4768
  • [44] Analysis of Chlorothalonil by Liquid Chromatography/Mass Spectrometry Using Negative-ion Atmospheric Pressure Photoionization
    Yamamoto, Atsushi
    Miyamato, Lori
    Kitagawa, Mikiya
    Moriwaki, Hiroshi
    Miyakoda, Hidekazu
    Kawasaki, Hideya
    Arakawa, Ryuichi
    ANALYTICAL SCIENCES, 2009, 25 (05) : 693 - 697
  • [45] Analysis of oligonucleotides by ion-pair reversed-phase liquid chromatography coupled with positive mode electrospray ionization mass spectrometry
    Weng, Guofeng
    Sun, Binwen
    Liu, Zheyi
    Wang, Fangjun
    Pan, Yuanjiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (18) : 4167 - 4173
  • [46] Selective monitoring of acidic and basic compounds in environmental water by capsule phase microextraction using sol-gel mixed-mode sorbents followed by liquid chromatography-mass spectrometry in tandem
    Carles Nadal, Joan
    Borrull, Francesc
    Furton, Kenneth G.
    Kabir, Abuzar
    Fontanals, Nuria
    Maria Marce, Rosa
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1625
  • [47] New Sol-Gel Hybrid Material in Solid Phase Extraction Combined with Liquid Chromatography for the Determination of Non-steroidal Anti-inflammatory Drugs in Water Samples
    Abd Rahim, Mashkurah
    Ibrahim, Wan Aini Wan
    Ramli, Zainab
    Sanagi, Mohd Marsin
    Aboul-Enein, Hassan Y.
    CHROMATOGRAPHIA, 2016, 79 (7-8) : 421 - 429
  • [48] Optimization and Evaluation of a Sheathless Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry Platform for Peptide Analysis: Comparison to Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Faserl, Klaus
    Sarg, Bettina
    Kremser, Leopold
    Lindner, Herbert
    ANALYTICAL CHEMISTRY, 2011, 83 (19) : 7297 - 7305
  • [49] Direct Fabrication of a Copper RTD over a Ceramic-Coated Stainless-Steel Tube by Combination of Magnetron Sputtering and Sol-Gel Techniques
    Bikarregi, Aitor
    Dominguez, Santiago
    Brizuela, Marta
    Lopez, Alejandra
    Suarez-Vega, Ana
    Agustin-Saenz, Cecilia
    Presa, Micael
    Lopez, Gabriel A.
    SENSORS, 2023, 23 (12)
  • [50] Regioisomeric analysis of triacylglycerols using silver-ion liquid chromatography atmospheric pressure chemical ionization mass spectrometry: Comparison of five different mass analyzers
    Holcapek, Michal
    Dvorakova, Hana
    Lisa, Miroslav
    Jimenez Giron, Ana
    Sandra, Pat
    Cvacka, Josef
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (52) : 8186 - 8194