Method for Accurate Quantitation of Volatile Organic Compounds in Urine Using Point of Collection Internal Standard Addition

被引:4
作者
Chambers, David M. [1 ]
Edwards, Kasey C. [1 ]
Sanchez, Eduardo [1 ]
Reese, Christopher M. [1 ]
Fernandez, Alai T. [1 ]
Blount, Benjamin C. [1 ]
De Jesus, Victor R. [1 ]
机构
[1] Ctr Dis Control & Prevent, Tobacco & Volatiles Branch, Div Lab Sci, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
来源
ACS OMEGA | 2021年 / 6卷 / 19期
关键词
SOLID-PHASE MICROEXTRACTION; OCCUPATIONAL-EXPOSURE; MASS SPECTROMETRY; BLOOD; SOLVENTS; BIOMARKERS; GASES; FUEL;
D O I
10.1021/acsomega.1c00854
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A method to achieve accurate measurement of unmetabolized volatile organic compounds (VOCs) in urine was developed and characterized. The method incorporates a novel preanalytical approach of adding isotopically labeled internal standard (ISTD) analogues directly to the collection container at the point of collection to compensate for analyte loss to the headspace and the collection container surfaces. Using this approach, 45 toxic VOCs ranging in water solubility and boiling point were evaluated and analyzed by headspace solid-phase microextraction/gas chromatography-mass spectrometry. Results show that urine VOCs could be equally lost to the container headspace as to the container surface suggesting similarity of these two regions as partition phases. Surface adsorption loss was found to trend with compound water solubility. In particular, with no headspace, more nonpolar VOCs experienced substantial losses (e.g., 48% for hexane) in a standard 120 mL urine cup at concentrations in the low- and sub-ppb range. The most polar VOCs evaluated (e.g., tetrahydrofuran) showed no significant loss. Other commonly practiced methods for urine sample collection and analysis such as aliquoting, specimen freezing, and use of surrogate ISTD were found to significantly bias results. With this method, we achieved errors ranging from -8.0 to 4.8% of spiked urine specimens. Paired urine and blood specimens from cigarette smokers were compared to assess this method.
引用
收藏
页码:12684 / 12690
页数:7
相关论文
共 31 条
  • [21] Evaluation of the Sealing Capability of the Implant Healing Screw by Using Real Time Volatile Organic Compounds Analysis: Internal Hexagon Versus Cone Morse
    Scarano, A.
    Lorusso, C.
    Di Giulio, C.
    Mazzatenta, A.
    JOURNAL OF PERIODONTOLOGY, 2016, 87 (12) : 1492 - 1498
  • [22] Headspace Injection Method for Intermittent Sampling and Profiling Analyses of Volatile Organic Compounds Using Dielectric Barrier Discharge Ionization (DBDI)
    Heffernan, Daniel
    Oleinek, Frederik
    Schueler, Ayla
    Lau, Paak Wai
    Kudermann, Ju''rgen
    Meindl, Alina
    Senge, Mathias O.
    Strittmatter, Nicole
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2025, : 801 - 810
  • [23] Simultaneous Determination of 11 Volatile Organic Compounds Metabolites in Human Urine Using High Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry
    Wang Lei-Jun
    Li Gang
    Zheng Sai-Jing
    Fei Ting
    Liu Hong
    Qi Da-Wei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (01) : 121 - 126
  • [24] Comparative analysis of volatile organic compounds of breath and urine for distinguishing patients with liver cirrhosis from healthy controls by using electronic nose and voltammetric electronic tongue
    Zaim, Omar
    Diouf, Alassane
    El Bari, Nezha
    Lagdali, Naoual
    Benelbarhdadi, Imane
    Ajana, Fatima Zohra
    Llobet, Eduard
    Bouchikhi, Benachir
    ANALYTICA CHIMICA ACTA, 2021, 1184
  • [25] Establishment of a headspace-thermal desorption and gas chromatography-mass spectrometry method (HS-TD-GC-MS) for simultaneous detection of 51 volatile organic compounds in human urine: Application in occupational exposure assessment
    Zhang, Zhongheng
    Zhang, Qing
    Xi, Ye
    Zhou, Ying
    Zhan, Ming
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1722
  • [26] Single-Laboratory Validation of a Method for the Determination of Select Volatile Organic Compounds in Foods by Using Vacuum Distillation with Gas Chromatography/Mass Spectrometry
    Nyman, Patricia J.
    Limm, William
    Begley, Timothy H.
    Chirtel, Stuart J.
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (02) : 510 - 520
  • [27] SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANT (BHA AND BHT) CONCENTRATIONS IN PHARMACEUTICAL PREPARATIONS AND CHEWING GUMS USING THE H-POINT STANDARD ADDITION METHOD
    Ozgur, Mahmure
    Kalaycioglu, Zeynep
    Dulger, Oznur
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2017, 36 (02) : 211 - 222
  • [28] Direct determination of N-methyl-2-pyrrolidone metabolites in urine by HPLC-electrospray ionization-MS/MS using deuterium-labeled compounds as internal standard
    Suzuki, Yoshihiro
    Endo, Yoko
    Ogawa, Masanori
    Yamamoto, Shinobu
    Takeuchi, Akito
    Nakagawa, Tomoo
    Onda, Nobuhiko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3743 - 3747
  • [29] A multiple-method comparative study using GC-MS, AMDIS and in-house-built software for the detection and identification of "unknown" volatile organic compounds in breath
    Marder, Dana
    Tzanani, Nitzan
    Baratz, Adva
    Drug, Eyal
    Prihed, Hagit
    Weiss, Shay
    Ben-Chetrit, Eli
    Eichel, Roni
    Dagan, Shai
    Yishai Aviram, Lilach
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (10):
  • [30] DEVELOPMENT OF A SCREENING METHOD FOR THE DETERMINATION OF VOLATILE ORGANIC-COMPOUNDS IN BODY-FLUIDS AND ENVIRONMENTAL-SAMPLES USING PURGE-AND-TRAP GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    DUNEMANN, L
    HAJIMIRAGHA, H
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 199 - 206