Volar Plate Osteosynthesis of Distal Radius Fractures With Concurrent Prophylactic Carpal Tunnel Release Using a Hybrid Flexor Carpi Radialis Approach

被引:32
|
作者
Gwathmey, F. Winston, Jr.
Brunton, Lance M.
Pensy, Raymond A.
Chhabra, A. Bobby
机构
[1] Univ Virginia, Hand Ctr, Charlottesville, VA USA
[2] Univ Pittsburgh, Med Ctr, Dept Orthopaed Surg, Pittsburgh, PA USA
[3] Univ Maryland, Dept Orthopaed, Baltimore, MD 21201 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2010年 / 35A卷 / 07期
关键词
Carpal tunnel release; distal radius fracture; flexor carpi radialis approach; median nerve; NERVE COMPRESSION; INTERNAL-FIXATION; INTRAARTICULAR FRACTURES; OPEN REDUCTION; LOCKING-PLATE; COMPLICATIONS; NEUROPATHY;
D O I
10.1016/j.jhsa.2010.03.043
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To evaluate the safety and efficacy of a hybrid flexor carpi radialis (FCR) approach for volar plate osteosynthesis of displaced distal radius fractures with concurrent prophylactic carpal tunnel release (CTR) in patients without preoperative signs or symptoms of acute carpal tunnel syndrome secondary to the fracture. Methods A total of 68 displaced distal radius fractures in 65 eligible adult patients (35 men, 30 women; mean age, 48.6 +/- 15.4 y) who had volar plate osteosynthesis and concomitant prophylactic CTR through a hybrid FCR approach by a single surgeon were included in this study. A systematic chart review and subsequent telephone questionnaire were performed to identify any postoperative median nerve dysfunction, recurrent motor or palmar cutaneous branch injury, tendon injury, or other complications directly related to the approach. Results Reported symptoms consistent with late median nerve dysfunction were identified in 2 cases; however, no patients in this series required additional surgery for early or late median neuropathy. Furthermore, no cases of median nerve sensory or motor branch injury or tendon injury were identified. No other unforeseen complications specifically related to the approach were observed. Conclusions Volar plate osteosynthesis of distal radius fractures with a concurrent prophylactic CTR can be safely performed through the described hybrid FCR approach in patients without signs or symptoms of acute CTS. Routine release of the transverse carpal ligament with the hybrid FCR approach at the time of fracture fixation might reduce the incidence of postoperative median nerve dysfunction. (J Hand Surg 2010;35A:1082-1088. Copyright (C) 2010 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:1082 / 1088
页数:7
相关论文
共 43 条
  • [1] The Extended Flexor Carpi Radialis Approach for Concurrent Carpal Tunnel Release and Volar Plate Osteosynthesis for Distal Radius Fracture
    Tannan, Shruti C.
    Pappou, Ioannis P.
    Gwathmey, Frank W.
    Freilich, Aaron M.
    Chhabra, Abhinav Bobby
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10): : 2026 - 2031
  • [2] Absence of flexor carpi radialis identified during volar approach for fixation of distal radius fracture: A case report
    Irie T.
    Motomiya M.
    Iwasaki N.
    BMC Research Notes, 11 (1)
  • [3] Use of the "y" volar plate in the osteosynthesis of fractures of the distal radius
    Bonfiglio, Salvatore
    Salvo, Giancarlo
    Longo, Gianfranco
    Ortuso, Rocco
    Kory, Antonio
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2019, 70 (04) : 198 - 204
  • [4] Single-Incision Extensile Volar Approach to the Distal Radius and Concurrent Carpal Tunnel Release: Cadaveric Study
    Pensy, Raymond A.
    Brunton, Lance M.
    Parks, Brent G.
    Higgins, James P.
    Chhabra, A. Bobby
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (02): : 217 - 222
  • [5] Distal radius fracture fixation with a volar locking plate and endoscopic carpal tunnel release using a single 15 mm approach: Feasibility study
    Zemirline, A.
    Taleb, C.
    Naito, K.
    Vernet, P.
    Liverneaux, P.
    Lebailly, F.
    HAND SURGERY & REHABILITATION, 2018, 37 (04) : 231 - 237
  • [6] Biomechanical Properties of Volar Hybrid and Locked Plate Fixation in Distal Radius Fractures
    Sokol, Shima C.
    Amanatullah, Derek F.
    Curtiss, Shane
    Szabo, Robert M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (04): : 591 - 597
  • [7] Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
    Synek, Alexaner
    Borgmann, Lars
    Traxler, Hannes
    Huf, Wolfgang
    Euler, Ekkehard
    Chevalier, Yan
    Baumbach, Sebastian F.
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [8] Prevalence of Flexor Carpi Radialis Brevis in Chinese Patients with Volar Wrist Plating Performed for Distal Radius Fracture
    Cheng, Bernadette Lok Yiu
    Yau, Edmund Leung Kai
    Yip, Norman Wai Chuen
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (03) : 328 - 331
  • [9] Flexor Pollicis Longus Dysfunction After Volar Plate Fixation of Distal Radius Fractures
    Chilelli, Brian J.
    Patel, Ronak M.
    Kalainov, David M.
    Peng, Jie
    Zhang, Li-Qun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (09): : 1691 - 1697
  • [10] Intraoperative virtual implant planning for volar plate osteosynthesis of distal radius fractures
    Franke, J.
    Vetter, S. Y.
    Reising, K.
    Herrmann, S.
    Suedkamp, N. P.
    Gruetzner, P. A.
    von Recum, J.
    UNFALLCHIRURG, 2016, 119 (01): : 36 - 42