Noise reduction technique for fluorescence imaging in multifocal multiphoton microscopy

被引:0
作者
Ryu, Inkeon [1 ]
Park, Eunwoo [2 ]
Kim, Eunbin [1 ]
Kim, Daekeun [1 ]
机构
[1] Dankook Univ, Dept Mech Engn, Yongin, South Korea
[2] Pohang Univ Sci & Technol POSTECH, Dept Convergence IT Engn, Pohang, South Korea
来源
SPIE ADVANCED BIOPHOTONICS CONFERENCE (SPIE ABC 2021) | 2021年 / 12159卷
关键词
Multifocal multiphoton microscopy; Crosstalk; Noise reduction; Beam shaper;
D O I
10.1117/12.2624203
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multifocal multiphoton microscopy (MMM) by forming multifocal created with a lenslet array enables high-speed imaging than single-focal multiphoton microscopy. However, most multifocal multiphoton microscopy has a problem of degrading image quality compared to single-focal microscopes. In order to solve this problem, it is necessary to equalize the intensity of the multifocal incident light. The fluorescence signal emitted from the fluorescence material is determined by the intensity of the incident light, but compared to the single-focal multiphoton microscope, the incident light passing through the lenslet array not only causes problems in acquiring fluorescence images but also limits the field of view ( FOV). This problem was overcome by using a specially designed beam shaper to equalize the multifocal incident light intensity. Another problem with MMM is that typical biopsy samples are opaque, so light scattering occurs when light is irradiated onto the sample. This is a cause of the noise that degrades image quality by generating crosstalk in which fluorescence signals emitted from each focus deviate from the focal plane and interfere with each other. For the minimization of crosstalk, we set up the algorithm technology to correct the sensitivity non-uniformity between channels of multi-channel photomultiplier tubes (PMT). And to minimize crosstalk between PMT circuits, an independent short-channel photon discriminator was designed to expand the number of focal points of the MMM system. Among the problems of MMM, two techniques were introduced, and it was confirmed that the noise of the fluorescence image was reduced.
引用
收藏
页数:4
相关论文
共 50 条
[41]   Adaptive-subtraction Electromagnetic Interference Noise Reduction in Photoacoustic Imaging in Vivo [J].
Sun, Ruinxi ;
Huang, Zihao ;
Zhang, Fan ;
Gao, Feng ;
Gao, Fei .
2024 IEEE ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL JOINT SYMPOSIUM, UFFC-JS 2024, 2024,
[42]   Noise reduction in dual-energy computed tomography virtual monoenergetic imaging [J].
Liu, Chi-Kuang ;
Huang, Hsuan-Ming .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09) :104-113
[43]   Partial spatial coherence illumination in digital holographic microscopy: quantitative analysis of the resulting noise reduction [J].
Dohet-Eraly, Jerome ;
Yourassowsky, Catherine ;
El Mallahi, Ahmed ;
Dubois, Frank .
OPTICAL MICRO- AND NANOMETROLOGY VI, 2016, 9890
[44]   A simple noniterative principal component technique for rapid noise reduction in parallel MR images [J].
Patel, Anand S. ;
Duan, Qi ;
Robson, Philip M. ;
McKenzie, Charles A. ;
Sodickson, Daniel K. .
NMR IN BIOMEDICINE, 2012, 25 (01) :84-92
[45]   A Digital CCD Noise Reduction Technique Experimentally Tested on a Large Batch of Scientific Sensors [J].
Lapi, Agustin Javier ;
Blanco, Claudio Rodrigo Chavez ;
Chierchie, Fernando ;
Moroni, Guillermo Fernandez ;
Paolini, Eduardo Emilio ;
Estrada, Juan ;
Tiffenberg, Javier .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
[46]   Design of Multichannel Wiener Filter for Speech Enhancement in Hearing Aids and Noise Reduction Technique [J].
Modhave, Nayan ;
Karuna, Yepuganti ;
Tonde, Sourabh .
PROCEEDINGS OF 2016 ONLINE INTERNATIONAL CONFERENCE ON GREEN ENGINEERING AND TECHNOLOGIES (IC-GET), 2016,
[47]   Impact of Acoustic Noise Reduction on Patient Experience in Routine Clinical Magnetic Resonance Imaging [J].
Sartoretti, Elisabeth ;
Sartoretti, Thomas ;
Wyss, Michael ;
van Smoorenburg, Luuk ;
Eichenberger, Barbara ;
van der Duim, Steven ;
Cereghetti, Damiano ;
Binkert, Christoph A. ;
Sartoretti-Schefer, Sabine ;
Najafi, Arash .
ACADEMIC RADIOLOGY, 2022, 29 (02) :269-276
[48]   Noise Reduction Method for Partial Discharge Fluorescence Fiber Sensors Based on Optimized Empirical Wavelet Transform [J].
Hu, Chengyong ;
Huang, Yi ;
Deng, Chuanlu ;
Jia, Ming ;
Zhang, Qi ;
Wu, Peng ;
Lu, Yuncai ;
Li, Qun ;
Zhang, Xiaobei ;
Wang, Tingyun .
IEEE PHOTONICS JOURNAL, 2024, 16 (04)
[49]   MULTI-MICROPHONE NOISE REDUCTION TECHNIQUE BASED ON UPSAMPLING AND IIR-RLS FILTER [J].
Mohammed, Jafar Ramadhan .
ICSPC: 2007 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS, VOLS 1-3, PROCEEDINGS, 2007, :808-811
[50]   A Single Slope ADC With Row-Wise Noise Reduction Technique for CMOS Image Sensor [J].
Nie, Kaiming ;
Zha, Wanbin ;
Shi, Xiaolin ;
Li, Jiawen ;
Xu, Jiangtao ;
Ma, Jianguo .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2020, 67 (09) :2873-2882