Sensor for hydrogen peroxide based on Prussian Blue modified electrode: Improvement of the operational stability

被引:59
|
作者
de Mattos, IL
Gorton, L
Ruzgas, T
Karyakin, AA
机构
[1] UNESP, Fac Ciencias, Dept Quim, BR-17033360 Bauru, SP, Brazil
[2] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[3] Moscow MV Lomonosov State Univ, Dept Chem, Moscow 117234, Russia
关键词
D O I
10.2116/analsci.16.795
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Improvement of the operational stability of amperometric sensors based on Prussian Blue (PB) modified glassy carbon electrodes is presented. The long term performance of the sensors was evaluated by injection of hydrogen peroxide (5 mu M in potassium buffer) solutions in a flow-injection system during a period of 5 - 10 h. The following parameters were investigated and correlated with the performance of the sensor: the times for electrodeposition and electrochemical activation, temperature, storage time, pH, composition of the buffer solution and of volume sample injected. These analytical characteristics of the modified electrode can be emphasized: initial sensitivity of 0.3 A cm(-2) M-1, detection limit of cn. 0.5 mu M, precise results (r.s.d.< 1.5%) and possibility to carry out around 50 samples (50 mu L) per hour.
引用
收藏
页码:795 / 798
页数:4
相关论文
共 50 条
  • [21] An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
    Ping, Jianfeng
    Wu, Jian
    Fan, Kai
    Ying, Yibin
    FOOD CHEMISTRY, 2011, 126 (04) : 2005 - 2009
  • [22] A Prussian Blue Modified Electrode Based Amperometric Sensor for Lactate Determination
    Kuntawong, Parnpim
    Lertanantawong, Benchaporn
    Promptmas, Chamras
    2022 14TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2022), 2022,
  • [23] Electrochemical Behavior of Hydrogen Peroxide at Nanocomposite of Prussian Blue with Palladium of Variable Nanogeometery Modified Electrode
    Pandey, Prem C.
    Pandey, Ashish Kumar
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (11) : G128 - G136
  • [24] Electrocatalytic reduction of hydrogen peroxide at Prussian blue modified electrode: An in situ Raman spectroelectrochemical study
    Mazeikiene, Regina
    Niaura, Gediminas
    Malinauskas, Albertas
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 140 - 146
  • [25] Prussian blue-modified nanoporous gold film electrode for amperometric determination of hydrogen peroxide
    Ghaderi, Seyran
    Mehrgardi, Masoud Ayatollahi
    BIOELECTROCHEMISTRY, 2014, 98 : 64 - 69
  • [26] Sensor for traces of hydrogen peroxide using an electrode modified by multiwalled carbon nanotubes, a gold-chitosan colloid, and Prussian blue
    Mengyao Li
    Guoqing Zhao
    Zenglian Yue
    Shasheng Huang
    Microchimica Acta, 2009, 167 : 167 - 172
  • [27] Screen Printed Biosensor for Hydrogen Peroxide Based on Prussian Blue Modified Hydroxyapatite
    Li, Yuyang
    Lv, Xiaohui
    Wu, Dan
    Ma, Hongmin
    Feng, Rui
    Wang, Yulan
    Du, Bin
    Wei, Qin
    JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2013, 23 (04) : 917 - 922
  • [28] Screen Printed Biosensor for Hydrogen Peroxide Based on Prussian Blue Modified Hydroxyapatite
    Yuyang Li
    Xiaohui Lv
    Dan Wu
    Hongmin Ma
    Rui Feng
    Yulan Wang
    Bin Du
    Qin Wei
    Journal of Inorganic and Organometallic Polymers and Materials, 2013, 23 : 917 - 922
  • [29] Sensor for traces of hydrogen peroxide using an electrode modified by multiwalled carbon nanotubes, a gold-chitosan colloid, and Prussian blue
    Li, Mengyao
    Zhao, Guoqing
    Yue, Zenglian
    Huang, Shasheng
    MICROCHIMICA ACTA, 2009, 167 (3-4) : 167 - 172
  • [30] Enhanced hydrogen peroxide sensing based on Prussian Blue modified macroporous microelectrodes
    Mokrushina, Anna V.
    Heim, Matthias
    Karyakina, Elena E.
    Kuhn, Alexander
    Karyakin, Arkady A.
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 29 : 78 - 80