Subcritical Water Chromatography with Electrochemical Detection

被引:1
作者
Anderson, Heather [1 ]
Yang, Yu [1 ]
机构
[1] East Carolina Univ, Dept Chem, Sci & Technol Bldg 584, Greenville, NC 27858 USA
关键词
subcritical water chromatography; hot water chromatography; electrochemical detection; neurotransmitters; nucleic acids; heterocyclic bases; capsaicinoids; TEMPERATURE LIQUID-CHROMATOGRAPHY; MAGNETIC-RESONANCE-SPECTROSCOPY; SUPERHEATED DEUTERIUM-OXIDE; FLAME IONIZATION DETECTION; MOBILE-PHASE; SEPARATION;
D O I
10.3390/molecules22060962
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Reverse phase liquid chromatography (RPLC) is a commonly used separation and analysis technique. RPLC typically employs mixtures of organic solvents and water or aqueous buffers as the mobile phase. With RPLC being used on a global scale, enormous quantities of organic solvents are consumed every day. In addition to the purchasing cost of the hazardous solvents, the issue of waste disposal is another concern. At ambient temperature, water is too polar to dissolve many organic substances. Therefore, although water is nontoxic it cannot be used to replace the mobile phase in RPLC since organic analytes will not be eluted. Subcritical water chromatography may be an alternative. The characteristics of water, such as polarity, surface tension, and viscosity, can be altered by manipulating water's temperature, thus making it behave like an organic solvent. The aim of this study was to evaluate the feasibility of separation using water mobile phase and detection by an electrochemical (EC) detector. The classes of analytes studied were neurotransmitters/metabolites, nucleic acids/heterocyclic bases, and capsaicinoids. Both isothermal and temperature-programmed separations were carried out. The separation temperature ranged from 25 to 100 degrees C. For separations of all three classes of solutes, the retention time was decreased with increasing temperature, thus shortening the analysis time. The peaks also became narrower as temperature increased. The limit of detection of neurotransmitters/metabolites ranges from 0.112 to 0.224 ppm.
引用
收藏
页数:13
相关论文
共 19 条
  • [1] Synthesis and evaluation of NA-PHEMAH polymer for use as a new stationary phase in high-temperature liquid chromatography
    Akay, Sema
    Odabasi, Mehmet
    Yang, Yu
    Kayan, Berkant
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 152 : 1 - 6
  • [2] Green chiral HPLC study of the stability of Chiralcel OD under high temperature liquid chromatography and subcritical water conditions
    Droux, S.
    Roy, M.
    Felix, G.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 968 : 22 - 25
  • [3] Superheated water as chromatographic eluent for parabens separation on octadecyl coated zirconia stationary phase
    Dugo, Paola
    Buonasera, Katia
    Crupi, Maria Lucia
    Cacciola, Francesco
    Dugo, Giovanni
    Mondello, Luigi
    [J]. JOURNAL OF SEPARATION SCIENCE, 2007, 30 (08) : 1125 - 1130
  • [4] Separation of sunscreens in skincare creams using greener high-temperature liquid chromatography and subcritical water chromatography
    Kapalavavi, B.
    Marple, R.
    Gamsky, C.
    Yang, Y.
    [J]. INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 2012, 34 (02) : 169 - 175
  • [5] Subcritical water chromatography with flame ionization detection
    Miller, DJ
    Hawthorne, SB
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (04) : 623 - 627
  • [6] Analysis of a ginger extract by high-performance liquid chromatography coupled to nuclear magnetic resonance spectroscopy using superheated deuterium oxide as the mobile phase
    Saha, S
    Smith, RM
    Lenz, E
    Wilson, ID
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 991 (01) : 143 - 150
  • [7] A comparison of hydrocarbon and alkali metal response in the flame ionization detector used in subcritical water chromatography
    Scott, Andrea F.
    Thurbide, Kevin B.
    Quickfall, Danica
    [J]. CANADIAN JOURNAL OF CHEMISTRY, 2015, 93 (07) : 784 - 789
  • [8] Skoog D. A., 2018, PRINCIPLES INSTRUMEN
  • [9] Superheated deuterium oxide reversed-phase chromatography coupled to proton nuclear magnetic resonance spectroscopy
    Smith, RM
    Chienthavorn, O
    Wilson, ID
    Wright, B
    [J]. ANALYTICAL COMMUNICATIONS, 1998, 35 (08): : 261 - 263
  • [10] Superheated water chromatography - A green technology for the future
    Smith, Roger M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 441 - 455