Perioperative Coagulation Profile in Living Liver Donors as Assessed by Rotational Thromboelastometry

被引:12
作者
Gouvea, Glauber [1 ,2 ,4 ]
Diaz, Rodrigo [1 ,2 ,4 ]
Auler, Lucio [1 ,2 ]
Toledo, Renato [1 ,2 ,5 ]
Soluri, Andre [1 ,2 ,5 ]
Haack, Alfredo G. [1 ,2 ]
de Oliveira, Mariana M. [1 ]
Vilanova, Bruno [1 ]
Machado, Virginia R. [1 ]
Martinho, Jose Manoel [3 ,6 ]
机构
[1] Bonsucesso Gen Hosp, Dept Anesthesiol, Rio De Janeiro, Brazil
[2] Bonsucesso Gen Hosp, Liver Transplantat Unit, Rio De Janeiro, Brazil
[3] Bonsucesso Gen Hosp, Dept Hepatobiliary Surg, Rio De Janeiro, Brazil
[4] Univ Fed Rio de Janeiro, Dept Anesthesiol, Rio De Janeiro, Brazil
[5] Natl Heart Inst Laranjeiras, Dept Anesthesiol, Rio De Janeiro, Brazil
[6] Univ Fed Fluminense, Dept Surg, Niteroi, RJ, Brazil
关键词
BLOOD-COAGULATION; RIGHT HEPATECTOMY; TRANSPLANTATION; HYPERCOAGULABILITY; THROMBOSIS; TESTS;
D O I
10.1002/lt.22011
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Transient postoperative coagulation abnormalities frequently occur in living liver donors, particularly after right liver resection Usually, this coagulopathy is diagnosed by alterations in conventional coagulation tests (CCTs) such as the international normalized ratio (INR) of the prothrombin time However, recent studies using other methods of coagulation monitoring have suggested that postoperative hypercoagulability may also occur in living donors. The rotational thromboelastometry (ROTEM) system is a coagulation monitor based on the viscoelastic properties of blood The use of ROTEM for perioperative coagulation monitoring in the setting of living liver donors has not been reported We evaluated the perioperative coagulation profile as assessed by ROTEM in 16 consecutive donors who underwent either right or left liver resection at our institution ROTEM analysis and CCTs were performed at the baseline (before skin incision) and on postoperative days 1 and 3 According to the CCTs, hypocoagulability was revealed in all but 1 (left liver) donor The INR was highest on postoperative day 1 [median = 1 67 (interquartile range = 1 37-1 8)] In contrast, all donors had a normal coagulation profile as assessed by the ROTEM system throughout the study period In conclusion, this study showed the disagreement between the CCTs and the ROTEM system, as no significant coagulation abnormalities could be revealed with the latter method during the study period Further studies are needed to confirm the role of the ROTEM system as a perioperative coagulation monitor in this setting and ultimately its influence on the outcome of living donors Liver Transpl 16:387392. 2010. (C) 2010 AASLD.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 16 条
[1]   Hypercoagulability after partial liver resection [J].
Bezeaud, Annie ;
Denninger, Marie Helene ;
Dondero, Federica ;
Saada, Veronique ;
Venisse, Laurence ;
Huisse, Marie Genevieve ;
Belghiti, Jacques ;
Guillin, Marie Claude .
THROMBOSIS AND HAEMOSTASIS, 2007, 98 (06) :1252-1256
[2]   Thromboelastogram monitoring in the perioperative period of hepatectomy for adult living liver donation [J].
Cerutti, E ;
Stratta, C ;
Romagnoli, R ;
Schellino, MM ;
Skurzak, S ;
Rizzetto, M ;
Tamponi, G ;
Salizzoni, M .
LIVER TRANSPLANTATION, 2004, 10 (02) :289-294
[3]   The changes in coagulation profile and epidural catheter safety for living liver donors: a report on 6 years of our experience [J].
Choi, Soo Joo ;
Gwak, Mi Sook ;
Ko, Justin Sang ;
Kim, Gaab Soo ;
Ahn, Hyun Joo ;
Yang, Mikyung ;
Hahm, Tae Soo ;
Lee, Sang Min ;
Kim, Myung Hee ;
Joh, Jae Won .
LIVER TRANSPLANTATION, 2007, 13 (01) :62-70
[4]   Transfusion triggers in orthotopic liver transplantation: A comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests [J].
Coakley, Margaret ;
Reddy, Kalpana ;
Mackie, Ian ;
Mallett, Susan .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (04) :548-553
[5]   Live donor liver transplantation in adults [J].
Fan, Sheung Tat .
TRANSPLANTATION, 2006, 82 (06) :723-732
[6]   Live donor liver transplantation [J].
Florman, S ;
Miller, CM .
LIVER TRANSPLANTATION, 2006, 12 (04) :499-510
[7]   The TEG® vs the ROTEM® thromboelastography/thromboelastometry systems [J].
Jackson, G. N. B. ;
Ashpole, K. J. ;
Yentis, S. M. .
ANAESTHESIA, 2009, 64 (02) :212-215
[8]   Hypercoagulability risks among adult living liver donors [J].
Lambing, A. ;
Kuriakose, P. ;
Abouljoud, M. S. .
TRANSPLANTATION PROCEEDINGS, 2006, 38 (10) :3579-3581
[9]   Multi-centre investigation on reference ranges for ROTEM thromboelastometry [J].
Lang, T ;
Bauters, A ;
Braun, SL ;
Pötzsch, B ;
von Pape, KW ;
Kolde, HJ ;
Lakner, M .
BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 (04) :301-310
[10]   Fibrinogen measurement to assess the risk of arterial thrombosis in individual patients: yes [J].
Meade, TW .