Efficacy and safety of preoperative intra-aortic balloon pump use in patients undergoing cardiac surgery: a systematic review and meta-analysis

被引:38
作者
Poirier, Yann [1 ]
Voisine, Pierre [1 ]
Plourde, Guillaume [1 ]
Rimac, Goran [1 ]
Perez, Alberto Barria [1 ]
Costerousse, Olivier [1 ]
Bertrand, Olivier F. [1 ]
机构
[1] Univ Laval, Quebec Heart Lung Inst, Quebec City, PQ, Canada
关键词
IABP; Preoperative IABP; Cardiac surgery; Meta-analysis; HIGH-RISK PATIENTS; LEFT-VENTRICULAR FUNCTION; CORONARY-BYPASS SURGERY; MYOCARDIAL-INFARCTION; SUPPORT; GRAFT; COUNTERPULSATION; PREDICTORS; INSERTION; SURVIVAL;
D O I
10.1016/j.ijcard.2016.01.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Intra-aortic balloon pump (IABP) can be used prior to coronary artery bypass graft surgery (CABG) in high-risk patients. Whether this technique remains safe and effective in contemporary practice is controversial. Objective: We have completed a systematic review and meta-analysis of randomized trials and observational studies to evaluate the safety and benefits of IABP prior to CABG surgery. Methods: We searched PubMed, EMBASE, Cochrane Library databases, with cross-referencing of relevant articles for studies assessing the impact of IABP prior to and after isolated CABG. Two investigators independently sorted the potentially relevant studies, and three extracted data. The assessed outcomes included in-hospital and 30-day mortality, IABP-related complications and length of intensive care unit and hospital stay. Results: From 1977 to 2015 we included 11 randomized controlled trials (n = 1293) (RCTs) and 22 observational studies, including a total of 46,067 patients. Analyses from RCTs suggested that IABP prior to CABG was associated with a significant reduction in hospital mortality (odds ratio (OR) 0.20; 95% confidence interval (CI): 0.09-0.44; P < 0.0001) and 30-day mortality compared to no preoperative IABP (OR 0.43, 95% CI: 0.25-0.76; P = 0.003). IABP prior to CABG was also associated with shorter intensive care unit (weighted mean difference (WMD) - 1.47 day; 95% CI: - 1.82 to - 1.12 day; P < 0.00001) and hospital length of stay (WMD - 3.25 days; 95% CI: - 5.18 to - 1.33 days; P = 0.0009). However, there were significant bias and limitations among included studies. Furthermore, results for similar outcomes from observational studies remained inconclusive. Conclusions: In contemporary practice, evidence showing clinical benefit for preoperative IABP in high-risk patients remains limited and requires further validation in an appropriately sized multicenter randomized trial. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
[31]   The Use of Intra-Aortic Balloon Pump in Patients. Undergoing Heart Valve Replacement: Outcome and Risk Analysis [J].
Zhang, Xi-Wu ;
Song, Zhi-Gang ;
Wang, Lv ;
Lu, Fang-Lin ;
Han, Lin ;
Zou, Liang-Jian ;
Xu, Ji-Bin ;
Xu, Zhi-Yun .
JOURNAL OF HEART VALVE DISEASE, 2014, 23 (04) :458-462
[32]   Re: Preoperative intra-aortic counterpulsation in high-risk patients undergoing cardiac surgery: a meta-analysis of randomized controlled trials [J].
Yang, Stephen Su .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (01) :193-194
[33]   Clinical application of intra-aortic balloon pump in patients with cardiogenic shock during the perioperative period of cardiac surgery [J].
Jiang, Xuesong ;
Zhu, Zhitao ;
Ye, Ming ;
Yan, Yan ;
Zheng, Junbo ;
Dai, Qingqing ;
Wen, Lianghe ;
Wang, Huaiquan ;
Lou, Shaofei ;
Ma, Hongmei ;
Ma, Pingwei ;
Li, Yunlong ;
Yang, Tuoyun ;
Zuo, Shu ;
Tian, Ye .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 13 (05) :1741-1748
[34]   Short-term outcomes of intra-aortic balloon pump combined with venoarterial extracorporeal membrane oxygenation: A systematic review and meta-analysis [J].
Wang, Li ;
Xing, Zhen .
ARTIFICIAL ORGANS, 2019, 43 (06) :561-568
[35]   Preoperative Intra-Aortic Balloon Pumping in High-Risk Cardiac Surgery Patients [J].
Moon, Chooza .
DIMENSIONS OF CRITICAL CARE NURSING, 2012, 31 (04) :223-227
[36]   A Randomized Controlled Trial of Preoperative Intra-Aortic Balloon Pump in Coronary Patients With Poor Left Ventricular Function Undergoing Coronary Artery Bypass Surgery [J].
Ranucci, Marco ;
Castelvecchio, Serenella ;
Biondi, Andrea ;
de Vincentiis, Carlo ;
Ballotta, Andrea ;
Varrica, Alessandro ;
Frigiola, Alessandro ;
Menicanti, Lorenzo .
CRITICAL CARE MEDICINE, 2013, 41 (11) :2476-2483
[37]   Complications associated with intra-aortic balloon pump treatment in critically ill patients: A systematic review [J].
Motia, Ngoe ;
Marko, Vasilika ;
Karlsen, Marte-Marie Wallander .
NURSING IN CRITICAL CARE, 2024, 29 (06) :1768-1780
[38]   Impact of previous cardiac surgery on patients undergoing transcatheter aortic valve implantation: A meta-analysis [J].
Bajaj, Anurag ;
Sethi, Arjinder ;
Rathor, Parul ;
Sehgal, Vishal ;
Pancholy, Samir .
HEART & LUNG, 2016, 45 (04) :350-358
[39]   Pro: Prophylactic Preoperative Use of an Intra-aortic Balloon Pump Is Indicated in High-Risk Coronary Patients Undergoing Coronary Artery Bypass Grafting [J].
Zaky, Ahmed .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (02) :532-533
[40]   Factors associated with pulmonary dysfunction in patients undergoing coronary artery bypass graft surgery with use of intra-aortic balloon pump [J].
Goncalves Fusatto, Helena Amaral ;
de Figueiredo, Luciana Castilho ;
Ragonete dos Anjos Agostini, Ana Paula ;
Sibinelli, Melissa ;
Dragosavac, Desanka .
REVISTA PORTUGUESA DE CARDIOLOGIA, 2018, 37 (01) :15-23