Minimally invasive determination of cardiac output by transthoracic bioimpedance, partial carbon dioxide rebreathing, and transesophageal Doppler echocardiography in beagle dogs
被引:17
作者:
Yamashita, Kazuto
论文数: 0引用数: 0
h-index: 0
机构:
Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, JapanRakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
Yamashita, Kazuto
[1
]
Ueyama, Yukie
论文数: 0引用数: 0
h-index: 0
机构:Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
Ueyama, Yukie
Miyoshi, Kenjiro
论文数: 0引用数: 0
h-index: 0
机构:Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
Miyoshi, Kenjiro
Igarashi, Ritsuyo
论文数: 0引用数: 0
h-index: 0
机构:Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
Igarashi, Ritsuyo
Kushiro, Tokiko
论文数: 0引用数: 0
h-index: 0
机构:Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
Kushiro, Tokiko
Umar, Mohammed A.
论文数: 0引用数: 0
h-index: 0
机构:Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
Umar, Mohammed A.
Muir, William W.
论文数: 0引用数: 0
h-index: 0
机构:Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
Muir, William W.
机构:
[1] Rakuno Gakuen Univ, Sch Vet Med, Dept Small Anim Clin Sci, Ebetsu, Hokkaido 0698501, Japan
[2] Kushiro Anim Hosp, Hokkaido Anim Med Ctr, Kushiro, Hokkaido 0850008, Japan
[3] Ohio State Univ, Coll Vet Med, Dept Vet Clin Sci, Columbus, OH 43210 USA
Minimally invasive cardiac output was determined using transthoracic bioimpedance (BICO), partial carbon dioxide rebreathing (NICO) and transesophageal Doppler echocardiography (TEECO) and compared to thermodilution (TDCO) in 6 beagle dogs. The dogs were 2 years old, weigh between 9.1-13.0 kg and were anesthetized with nitrous oxide-oxygen-sevoflurane. All dogs were administered a neuromuscular blocking drug and artificially ventilated during anesthesia. Thirty paired measurements of TDCO and each non-invasive method were collected during low, intermediate, and high values of cardiac output achieved by varying the depth of anesthesia and the administration of dobutamine. Cardiac output values ranged from 1.10-2.50 L/min for BICO compared to 0.81-4.88 L/min for TDCO; 0.70-2.60 L/min for NICO compared to 0.89-4.45 L/min for TDCO; and 0.59-4.37 L/min for TEECO compared to 0.57-4.15 L/min for TDCO. The limits of agreement and percentage error were -0.58 +/- 1.56 L/min and +/- 75.4% for BICO, -1.04 +/- 1.08 L/min and +/- 56.0% for NICO, and 0.03 +/- 0.26 L/min and +/- 12.3% for TEECO compared to TDCO. In conclusion, TEECO provided the best agreement to TDCO in sevoflurane anesthetized beagle dogs.
机构:
Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Peoples R ChinaChinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Peoples R China
Critchley, LAH
Critchley, JAJH
论文数: 0引用数: 0
h-index: 0
机构:Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Peoples R China
机构:
Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Peoples R ChinaChinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Peoples R China
Critchley, LAH
Critchley, JAJH
论文数: 0引用数: 0
h-index: 0
机构:Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Peoples R China