Three-photon imaging using defect-induced photoluminescence in biocompatible ZnO nanoparticles

被引:11
作者
Raghavendra, Achyut J. [1 ]
Gregory, Wren E. [1 ]
Slonecki, Tyler J. [2 ]
Dong, Yongchang [1 ]
Persaud, Indushekhar [3 ]
Brown, Jared M. [3 ]
Bruce, Terri F. [2 ]
Podila, Ramakrishna [1 ,4 ,5 ]
机构
[1] Clemson Univ, Dept Phys & Astron, Clemson Nanomat Inst, Lab Nanobiophys, Clemson, SC USA
[2] Clemson Univ, Clemson Light Imaging Facil, Clemson, SC USA
[3] Univ Colorado, Skaggs Sch Pharm & Pharmaceut Sci, Dept Pharmaceut Sci, Anschutz Med Campus, Aurora, CO USA
[4] Clemson Univ, Sch Hlth Res, Clemson, SC USA
[5] Clemson Univ, COMSET, Clemson, SC USA
来源
INTERNATIONAL JOURNAL OF NANOMEDICINE | 2018年 / 13卷
基金
美国国家科学基金会;
关键词
three-photon imaging; ZnO nanoparticles; defects; photoluminescence; GUIDED SURGERY; ABSORPTION;
D O I
10.2147/IJN.S165201
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Background: Although optical spectroscopy promises improved lateral resolution for cancer imaging, its clinical use is seriously impeded by background fluorescence and photon attenuation even in the so-called two-photon absorption (2PA) imaging modality. An efficient strategy to meet the clinical cancer imaging needs, beyond what two-photon absorption (2PA) offers, is to use longer excitation wavelengths through three-photon absorption (3PA). A variety of fluorescent dyes and nanoparticles (NPs) have been used in 3PA imaging. However, their nonlinear 3PA coefficient is often low necessitating high excitation powers, which cause overheating, photodamage, and photo-induced toxicity. Doped wide band gap semiconductors such as Mn:ZnS NPs have previously been used for 3PA but suffer from poor 3PA coefficients. Methods: Here, we prepared ZnO NPs with intrinsic defects with high 3PA coefficients using a polyol method. We functionalized them with peptides for selective uptake by glioblastoma U87MG cells and used breast cancer MCF-7 cells as control for 3PA studies. Uptake was measured using inductively coupled plasma-mass spectrometry. Biocompatibility studies were performed using reactive oxygen species and cell viability assays. Results: We demonstrate that ZnO NPs, which have a band gap of 3.37 eV with an order of magnitude higher 3PA coefficients, can facilitate the use of longer excitation wavelengths 950-1,100 nm for bioimaging. We used the presence intrinsic defects (such as O interstitials and Zn vacancies) in ZnO NPs to induce electronic states within the band gap that can support strong visible luminescence 550-620 nm without the need for extrinsic doping. The peptide functionalization of ZnO NPs showed selective uptake by U87MG cells unlike MCF-7 cells without the integrin receptors. Furthermore, all ZnO NPs were found to be biocompatible for 3PA imaging. Conclusion: We show that defect-induced luminescence 550-620 nm in ZnO NPs (20 nm) due to 3PA at longer excitation (975 nm) can be used for 3PA imaging of U87MG glioblastoma cells with lower background noise.
引用
收藏
页码:4283 / 4290
页数:8
相关论文
共 21 条
  • [1] The role of defects in the nonlinear optical absorption behavior of carbon and ZnO nanostructures
    Anand, Benoy
    Krishnan, S. R.
    Podila, Ramakrishna
    Sai, S. Siva Sankara
    Rao, Apparao M.
    Philip, Reji
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2014, 16 (18) : 8168 - 8177
  • [2] Defect Induced Changes in the Linear and Non-Linear Optical Properties of ZnO Nanotetrapods
    Egblewogbe, Martin
    Anand, Benoy
    Podila, Ramakrishna
    Philip, Reji
    Sai, S. Siva Sankara
    Rao, Apparao M.
    [J]. MATERIALS EXPRESS, 2012, 2 (04) : 351 - 356
  • [3] Image-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation
    Gioux, Sylvain
    Choi, Hak Soo
    Frangioni, John V.
    [J]. MOLECULAR IMAGING, 2010, 9 (05): : 237 - 255
  • [4] Gu B., 2008, J APPL PHYS, V103, P9235
  • [5] Cancer-Targeted Optical Imaging with Fluorescent Zinc Oxide Nanowires
    Hong, Hao
    Shi, Jian
    Yang, Yunan
    Zhang, Yin
    Engle, Jonathan W.
    Nickles, Robert J.
    Wang, Xudong
    Cai, Weibo
    [J]. NANO LETTERS, 2011, 11 (09) : 3744 - 3750
  • [6] Intraoperative Spectroscopy with Ultrahigh Sensitivity for Image-Guided Surgery of Malignant Brain Tumors
    Kairdolf, Brad A.
    Bouras, Alexandros
    Kaluzova, Milota
    Sharma, Abhinav K.
    Wang, May Dongmei
    Hadjipanayis, Constantinos G.
    Nie, Shuming
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (01) : 858 - 867
  • [7] Incidence of the core composition on the stability, the ROS production and the toxicity of CdSe quantum dots
    Kauffer, Florence-Anais
    Merlin, Christophe
    Balan, Lavinia
    Schneider, Raphael
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2014, 268 : 246 - 255
  • [8] Identification of Breast Cancer Margins Using Intraoperative Near-Infrared Imaging
    Keating, Jane
    Tchou, Julia
    Okusanya, Olugbenga
    Fisher, Carla
    Batiste, Rebecca
    Jiang, Jack
    Kennedy, Gregory
    Nie, Shuming
    Singhal, Sunil
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 2016, 113 (05) : 508 - 514
  • [9] ZnO nanoparticles with controlled shapes and sizes prepared using a simple polyol synthesis
    Lee, Sul
    Jeong, Sunho
    Kim, Dongjo
    Hwang, Sookhyun
    Jeon, Minhyon
    Moon, Jooho
    [J]. SUPERLATTICES AND MICROSTRUCTURES, 2008, 43 (04) : 330 - 339
  • [10] Trends in Fluorescence Image-Guided Surgery for Gliomas
    Liu, Jonathan T. C.
    Meza, Daphne
    Sanai, Nader
    [J]. NEUROSURGERY, 2014, 75 (01) : 61 - 71