The role of peripheral ocular length and peripheral corneal radius of curvature in determining refractive error

被引:5
作者
Alhussain, Saleh H. A. [1 ,3 ]
Mallen, Edward A. H. [2 ]
Strang, Niall C. [1 ]
Jonuscheit, Sven [1 ]
机构
[1] Glasgow Caledonian Univ, Sch Hlth & Life Sci, Dept Vis Sci, Glasgow, Scotland
[2] Univ Bradford, Sch Optometry & Vis Sci, Bradford, England
[3] King Fahad Hosp, Al Hufuf, Saudi Arabia
关键词
Refractive error; Myopia; Peripheral ocular length; Peripheral corneal radius of curvature; Axial length; PARTIAL COHERENCE INTERFEROMETRY; AXIAL LENGTH; RETINAL CONTOUR; THICKNESS; MYOPIA; EYE; REPEATABILITY; PENTACAM; ONSET; SHAPE;
D O I
10.1016/j.optom.2021.02.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to extend the knowledge of peripheral biometric component and its relationship to refractive status in healthy individuals by determining the correlation between peripheral ocular length to peripheral corneal radius ratio and the refractive error. Methods: This prospective study was conducted on thirty-three healthy adult participants. Refractive error was assessed objectively and subjectively and recorded as the mean spherical equivalent. Central and peripheral ocular lengths at 30 degrees were assessed using partial coherence interferometry under dilation with 1% tropicamide. Central and peripheral corneal radius of curvature was assessed using Scheimpflug topography. Peripheral ocular lengths at 30 degrees were paired with peripheral corneal curvatures at the incident points of the IOLMaster beam (3.8 mm away from corneal apex) superiorly, inferiorly, temporally and nasally to calculate the peripheral ocular length-peripheral corneal radius ratio. Descriptive statistics were used to describe the distribution and spread of the data. Pearson's correlation analysis was used to present the association between biometric and refractive variables. Results: Refractive error was negatively correlated with the axial length-central corneal radius ratio (r = -0.91; p < 0.001) and with 30 degrees peripheral ocular length-peripheral corneal radius ratio in all four meridians (r = -0.76; p < 0.001). The strength of the correlation was considerably lower when only axial length or peripheral ocular lengths were used. Conclusion: Using the ratios of peripheral ocular length-peripheral corneal radius to predict refractive error is more effective than using peripheral corneal radius or peripheral ocular length alone. (c) 2021 Spanish General Council of Optometry. Published by Elsevier Espana, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:129 / 137
页数:9
相关论文
共 34 条
[1]   Can Partial Coherence Interferometry be Used to Determine Retinal Shape? [J].
Atchison, David A. ;
Charman, W. Neil .
OPTOMETRY AND VISION SCIENCE, 2011, 88 (05) :E601-E607
[2]   Peripheral refraction in myopia corrected with spectacles versus contact lenses [J].
Backhouse, Simon ;
Fox, Stephanie ;
Ibrahim, Basma ;
Phillips, John R. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (04) :294-303
[3]   Peripheral Defocus and Myopia Progression in Myopic Children Randomly Assigned to Wear Single Vision and Progressive Addition Lenses [J].
Berntsen, David A. ;
Barr, Christopher D. ;
Mutti, Donald O. ;
Zadnik, Karla .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) :5761-5770
[4]  
Carl Zeiss Meditec Inc, 2000, US MAN IOLMASTER ADV
[5]   Eye Shape Using Partial Coherence Interferometry, Autorefraction, and SD-OCT [J].
Clark, Christopher A. ;
Elsner, Ann E. ;
Konynenbelt, Benjamin J. .
OPTOMETRY AND VISION SCIENCE, 2015, 92 (01) :115-122
[6]   Off-axis partial coherence interferometry in myopes and emmetropes [J].
Ehsaei, Asieh ;
Chisholm, Catharine M. ;
Pacey, Ian E. ;
Mallen, Edward A. H. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (01) :26-34
[7]   Correlation of central and peripheral corneal thickness in healthy corneas [J].
Fares, Usama ;
Otri, Ahmad Muneer ;
Al-Aqaba, Mouhamed Ali ;
Dua, Harminder S. .
CONTACT LENS & ANTERIOR EYE, 2012, 35 (01) :39-45
[8]  
Faria-Ribeiro Miguel, 2014, J Optom, V7, P75, DOI 10.1016/j.optom.2013.12.005
[9]   Computing Retinal Contour from Optical Biometry [J].
Faria-Ribeiro, Miguel ;
Lopez-Gil, Norberto ;
Navarro, Rafael ;
Lopes-Ferreira, Daniela ;
Jorge, Jorge ;
Gonzalez-Meijome, Jose Manuel .
OPTOMETRY AND VISION SCIENCE, 2014, 91 (04) :430-436
[10]   Shape of the Posterior Vitreous Chamber in Human Emmetropia and Myopia [J].
Gilmartin, Bernard ;
Nagra, Manbir ;
Logan, Nicola S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (12) :7240-7251