The Gas Chromatograph Mass Spectrometer for the Huygens Probe

被引:71
作者
Niemann, HB [1 ]
Atreya, SK
Bauer, SJ
Biemann, K
Block, B
Carignan, GR
Donahue, TM
Frost, RL
Gautier, D
Haberman, JA
Harpold, D
Hunten, DM
Israel, G
Lunine, JI
Mauersberger, K
Owen, TC
Raulin, F
Richards, JE
Way, SH
机构
[1] NASA, Greenbelt, MD 20771 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
[3] Graz Univ, Inst Meteorol & Geophys, A-8010 Graz, Austria
[4] MIT, Cambridge, MA 01239 USA
[5] Observ Paris, F-92195 Meudon, France
[6] Univ Arizona, Tucson, AZ 85716 USA
[7] CNRS, Serv Aeron, F-91371 Verrieres Les Buissons, France
[8] Max Planck Inst Kernphys, D-69029 Heidelberg, Germany
[9] Univ Alabama, CMC, Birmingham, AL 35205 USA
[10] Univ Hawaii, Honolulu, HI 96822 USA
[11] Univ Paris 12, Lab Interuniv Syst Atmospher, F-94010 Creteil, France
[12] Univ Paris 07, Lab Interuniv Syst Atmospher, F-94010 Creteil, France
关键词
D O I
10.1023/A:1023680305259
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of Titan's atmosphere from 170 km altitude(similar to1 hPa) to the surface (similar to1500 hPa) and determine the isotope ratios of the major gaseous constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to investigate the composition (including isotope ratios) of several candidate surface materials. The GCMS is a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employs five ion sources sequentially feeding the mass analyzer. Three ion sources serve as detectors for the GC columns and two are dedicated to direct atmosphere sampling and ACP gas sampling respectively. The instrument is also equipped with a chemical scrubber cell for noble gas analysis and a sample enrichment cell for selective measurement of high boiling point carbon containing constituents. The mass range is 2 to 141 Dalton and the nominal detection threshold is at a mixing ratio of 10(-8). The data rate available from the Probe system is 885 bit/s. The weight of the instrument is 17.3 kg and the energy required for warm up and 150 minutes of operation is 110 Watt-hours.
引用
收藏
页码:553 / 591
页数:39
相关论文
共 50 条
  • [31] THERMAL-DECOMPOSITION OF METHYLPHENIDATE IN GAS CHROMATOGRAPH MASS-SPECTROMETER
    FLAMM, BL
    GAL, J
    BIOMEDICAL MASS SPECTROMETRY, 1975, 2 (05): : 281 - 283
  • [32] A field deployable gas chromatograph mass spectrometer for industrial hygiene applications
    Piltingsrud, HV
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1997, 58 (08): : 564 - 577
  • [33] GAS CHROMATOGRAPH MASS SPECTROMETER INTERFACE - ANALYSIS OF MOLECULAR EFFUSION SEPARATOR
    FOCK, W
    ANALYTICAL CHEMISTRY, 1975, 47 (14) : 2447 - 2450
  • [34] A NEW MODE OF OPERATION OF INTEGRATED GAS CHROMATOGRAPH - MASS SPECTROMETER SYSTEMS
    GREEN, DE
    LITTLEJO.DP
    APPLIED SPECTROSCOPY, 1969, 23 (06) : 645 - &
  • [35] SAMPLE ENRICHMENT TECHNIQUES FOR A GAS CHROMATOGRAPH - MASS SPECTROMETER ANALYSIS SYSTEM
    LUCERO, DP
    HALEY, FC
    JOURNAL OF GAS CHROMATOGRAPHY, 1968, 6 (09): : 477 - &
  • [36] Gas chromatograph injection liner for continuous analyte admission into a mass spectrometer
    Corso, TN
    Van Pelt, CK
    Brenna, JT
    ANALYTICAL CHEMISTRY, 1998, 70 (05) : 1030 - 1032
  • [37] Screening and diagnosis for inherited metabolic diseases by gas chromatograph/mass spectrometer
    Meng, Y. T.
    Song, L.
    Zhang, Y. Q.
    Guo, J.
    Dang, L. H.
    Shan, Z. M.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2006, 29 : 83 - 83
  • [38] A 2 STAGE MOLECULAR SEPARATOR FOR INTERFACING A GAS CHROMATOGRAPH WITH A MASS SPECTROMETER
    GRAYSON, MA
    WOLF, CJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1969, (SEP): : AN69 - &
  • [39] Analysis of red phosphorus using a pyrolysis gas chromatograph/mass spectrometer
    Schieferecke, J
    Worley, D
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2004, 71 (01) : 47 - 50
  • [40] SPECIAL USES OF A GAS-CHROMATOGRAPH MASS-SPECTROMETER IN ENDOCRINOLOGY
    JOHNSON, DW
    BROOM, TJ
    COX, LW
    MATTHEWS, CD
    PHILLIPOU, G
    SEAMARK, RF
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1983, 19 (01) : 203 - 207