Change of Recipient Corneal Endothelial Cells After Non-Descemet's Stripping Automated Endothelial Keratoplasty in a Rabbit Model

被引:4
|
作者
Sun, Jen-Pin [1 ,2 ,3 ]
Hu, Fung-Rong [1 ,4 ]
Chen, Yan-Ming [5 ]
Chu, Hsiao-Sang [1 ]
Chen, Wei-Li [1 ,4 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Ophthalmol, Taipei, Taiwan
[2] Natl Taiwan Univ Hosp, Hsin Chu Branch, Dept Ophthalmol, Hsinchu, Taiwan
[3] Rayming Eye Clin, New Taipei City, Taiwan
[4] Natl Taiwan Univ Hosp, Ctr Corneal Tissue Engn & Stem Cell Biol, Taipei, Taiwan
[5] I Shou Univ, E Da Hosp, Dept Ophthalmol, Kaohsiung, Taiwan
关键词
DSAEK; nDSAEK; corneal endothelial cells; in vivo confocal microscopy; transmission electron microscopy; TRAUMATIC WOUND DEHISCENCE; PENETRATING KERATOPLASTY; BEVACIZUMAB AVASTIN; NEOVASCULARIZATION; TRANSPLANTATION; INJECTION; KERATITIS; TAIWAN;
D O I
10.1167/iovs.13-13544
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We used a rabbit model to evaluate the interface embedded between the recipient corneas and transplanted donor corneal discs after non-Descemet's stripping automated endothelial keratoplasty (nDSAEK). METHODS. Unilateral DSAEK and nDSAEK surgeries were performed on New Zealand white rabbits. In vivo confocal microscopy was performed to show: the changes in corneal endothelial cells embedded between the recipient corneas and the transplanted donor corneal discs (CEEB); and the interface opacity by z profile. Immunohistochemistry were performed to evaluate the functional change of CEEB at post-nDSAEK 3 months. Transmission electron microscopy was performed to evaluate the morphology of CEEB after nDSAEK at post-nDSAEK 1, 3, and 6 months. RESULTS. In vivo confocal microscopy showed a time-dependent decrease in the density of CEEB at postoperative 1, 2, or 3 months (P < 0.01). Interface opacity was higher in the nDSAEK group than the DSAEK group at all examination points, but the difference was statistically insignificant. At 3 months after surgery, the CEEB were negative for Na+/K(+-)ATPase staining. Staining with TUNEL showed apoptotic changes in some areas. During a 6-month observation, the CEEB showed a time-dependent thickening and loss of uniform thickness of cellular morphology. At 3 and 6 months post nDSAEK, extensions of the cellular processes into the donor graft stroma combined with intracellular vacuoles containing collagen-like materials were also found. CONCLUSIONS. After non-Descemet's stripping automated endothelial keratoplasty, the CEEB showed decreased density, loss of pump function, apoptosis and changed morphology. However, the interface opacity was not significantly greater compared with DSAEK eyes.
引用
收藏
页码:8467 / 8474
页数:8
相关论文
共 50 条
  • [1] A Study of Host Corneal Endothelial Cells After Non-Descemet Stripping Automated Endothelial Keratoplasty
    Hatanaka, Hiroki
    Koizumi, Noriko
    Okumura, Naoki
    Takahashi, Hiroaki
    Tanioka, Hidetoshi
    Young, Robert D.
    Jones, Frances E.
    Quantock, Andrew J.
    Kinoshita, Shigeru
    CORNEA, 2013, 32 (01) : 76 - 80
  • [2] Intraocular Pressure After Descemet's Stripping and Non-Descemet's Stripping Automated Endothelial Keratoplasty
    Mawatari, Yoshiro
    Kobayashi, Akira
    Yokogawa, Hideaki
    Sugiyama, Kazuhisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (02) : 98 - 102
  • [3] Intraocular pressure after Descemet’s stripping and non-Descemet’s stripping automated endothelial keratoplasty
    Yoshiro Mawatari
    Akira Kobayashi
    Hideaki Yokogawa
    Kazuhisa Sugiyama
    Japanese Journal of Ophthalmology, 2011, 55 : 98 - 102
  • [4] Intraocular Pressure After Descemet Stripping and Non-Descemet Stripping Automated Endothelial Keratoplasty
    Mawatari, Y.
    Kobayashi, A.
    Yokogawa, H.
    Sugiyama, K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Descemet stripping and automated endothelial keratoplasty (DSAEK) versus non-Descemet stripping and automated endothelial keratoplasty (nDSAEK) for bullous keratopathy
    Yamazaki, Risa
    Nejima, Ryohei
    Ichihashi, Yoshiyuki
    Miyata, Kazunori
    Tsubota, Kazuo
    Shimmura, Shigeto
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2020, 64 (06) : 585 - 590
  • [6] Descemet Stripping Automated Endothelial Keratoplasty Using Cultured Corneal Endothelial Cells in a Rabbit Model
    Honda, Norihiko
    Mimura, Tatsuya
    Usui, Tomohiko
    Amano, Shiro
    ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (10) : 1321 - 1326
  • [7] Clinical outcomes of non-Descemet stripping automated endothelial keratoplasty
    Sunita Chaurasia
    Muralidhar Ramappa
    Virender S. Sangwan
    International Ophthalmology, 2012, 32 (6) : 571 - 575
  • [8] Non-Descemet stripping automated endothelial keratoplasty for post radial keratotomy corneal edema
    Shah, Sushmita Gaurav
    Shah, Gaurav Y.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (09) : 1333 - +
  • [9] Descemet stripping and automated endothelial keratoplasty (DSAEK) versus non-Descemet stripping and automated endothelial keratoplasty (nDSAEK) for bullous keratopathy
    Risa Yamazaki
    Ryohei Nejima
    Yoshiyuki Ichihashi
    Kazunori Miyata
    Kazuo Tsubota
    Shigeto Shimmura
    Japanese Journal of Ophthalmology, 2020, 64 : 585 - 590
  • [10] Non-Descemet Stripping Descemet Membrane Endothelial Keratoplasty
    Park, Choul Yong
    Chuck, Roy S.
    CORNEA, 2013, 32 (12) : 1607 - 1609