A biphasic model for micro-indentation of a hydrogel-based contact lens

被引:34
作者
Chen, Xiaoming [1 ]
Dunn, Alison C. [1 ]
Sawyer, W. Gregory [1 ]
Sarntinoranont, Malisa [1 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 02期
关键词
hydraulic conductivity; pHEMA-MAA; poroelastic; porous media; exudation; FEM; computational model; biphasic; microindentation; ARTICULAR-CARTILAGE; HYDRAULIC PERMEABILITY; STRESS-RELAXATION; MECHANICAL-PROPERTIES; TENSILE PROPERTIES; PERMEATION; WATER; MICROINDENTATION; NANOINDENTATION; COMPRESSION;
D O I
10.1115/1.2472373
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The stiffness and hydraulic permeability of soft contact lenses may influence its clinical performance, e.g., on-eye movement, fitting, and wettability, and may be related to the occurrence of complications; e.g., lesions. It is therefore important to determine these properties in the design of comfortable contact lenses. Micro-indentation provides a nondestructive means of measuring mechanical properties of soft, hydrated contact lenses. However, certain geometrical and material considerations must be taken into account when analyzing output force-displacement (F-D) data. Rather than solely having a solid response, mechanical behavior of hydrogel contact lenses can be described as the coupled interaction between fluid transport through pores and solid matrix deformation. In addition, indentation of thin membranes (similar to 100 mu am) requires special consideration of boundary conditions at lens surfaces and at the indenter contact region. In this study, a biphasic finite element model was developed to simulate the micro-indentation of a hydrogel contact lens. The model accounts for a curved, thin hydrogel membrane supported on an impermeable mold. A time-varying boundary condition was implemented to model the contact interface between the impermeable spherical indenter and the lens. Parametric studies varying the indentation velocities and hydraulic permeability show F-D curves have a sensitive region outside of which the force response reaches asymptotic limits governed by either the solid matrix (slow indentation velocity, large permeability) or the fluid transport (high indentation velocity, low permeability). Using these results, biphasic properties (Young's modulus and hydraulic permeability) were estimated by fitting model results to F-D curves obtained at multiple indentation velocities (1.2 and 20 mu m/s). Fitting to micro-indentation tests of Etafilcon A resulted in an estimated permeability range of 1.0 X 10(-15) to 5.0 X 10(-15) M-4/N s and Young's modulus range of 130 to 170 kPa.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 36 条
[1]  
*ADINA INC, 2003, ADINA THEOR MOD GUID
[2]   Mechanical properties of hydrogels and their experimental determination [J].
Anseth, KS ;
Bowman, CN ;
BrannonPeppas, L .
BIOMATERIALS, 1996, 17 (17) :1647-1657
[3]   Indentation testing of human articular cartilage: Effects of probe tip geometry and indentation depth on intra-tissue strain [J].
Bae, WC ;
Lewis, CW ;
Levenston, ME ;
Sah, RL .
JOURNAL OF BIOMECHANICS, 2006, 39 (06) :1039-1047
[4]  
CHIARELLI P, 1992, BIORHEOLOGY, V29, P383
[5]   The tensile properties of alginate hydrogels [J].
Drury, JL ;
Dennis, RG ;
Mooney, DJ .
BIOMATERIALS, 2004, 25 (16) :3187-3199
[6]   Nanoindentation of soft hydrated materials for application to vascular tissues [J].
Ebenstein, DM ;
Pruitt, LA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 69A (02) :222-232
[7]   A nanoindentation technique for functional evaluation of cartilage repair tissue [J].
Ebenstein D.M. ;
Kuo A. ;
Rodrigo J.J. ;
Reddi A.H. ;
Ries M. ;
Pruitt L. .
Journal of Materials Research, 2004, 19 (01) :273-281
[8]  
ENNS JB, 1996, P 1996 54 ANN TECHN, V3, P2852
[9]   Surface micromechanics of ultrahigh molecular weight polyethylene: Microindentation testing, crosslinking, and material behavior [J].
Gilbert, JL ;
Cumber, J ;
Butterfield, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (02) :270-281
[10]   Investigation into the biphasic properties of a hydrogel for use in a cushion form replacement joint [J].
Goldsmith, AAJ ;
Clift, SE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (03) :362-369