Automatic frequency correction for quantification of magnetic resonance spectroscopic images

被引:0
|
作者
Wang, Y [1 ]
Van Huffel, S [1 ]
Heyvaert, E [1 ]
Vanhamme, L [1 ]
Van Hecke, P [1 ]
机构
[1] Katholieke Univ Leuven, Dept Elect Engn, B-3001 Louvain, Belgium
来源
MATHEMATICS IN SIGNAL PROCESSING V | 2002年 / 71期
关键词
D O I
暂无
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
We present two new methods based on Principal Component Analysis (PCA) using the complex Singular Value Decomposition (SVD) and cross-correlation of the magnitude spectra for correcting frequency shifts of resonances in sets of Magnetic Resonance (MR) spectra and spectroscopic images. After a description of the methods, we compare their performance on simulated data sets of Magnetic Resonance Spectroscopic Images and discuss their advantages and limitations.
引用
收藏
页码:229 / 239
页数:11
相关论文
共 50 条
  • [1] Automatic motion correction for quantification of myocardial perfusion using dynamic magnetic resonance imaging
    Kawakami, K
    Murase, K
    Kawakami, A
    Kumashiro, M
    Yamazaki, Y
    Tabuchi, T
    Nagayama, M
    Watanabe, Y
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1372 - 1372
  • [2] Correction of inhomogeneities in Magnetic Resonance Images
    Noterdaeme, Olivier
    Brady, Michael
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2221 - 2224
  • [3] Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
    Atkinson, D
    Hill, DLG
    Stoyle, PNR
    Summers, PE
    Keevil, SF
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) : 903 - 910
  • [4] Automatic segmentation of thigh magnetic resonance images
    Urricelqui, Lorena
    Malanda, Armando
    Villanueva, Arantxa
    World Academy of Science, Engineering and Technology, 2009, 34 : 531 - 537
  • [5] Automatic segmentation of thigh magnetic resonance images
    Urricelqui, Lorena
    Malanda, Armando
    Villanueva, Arantxa
    World Academy of Science, Engineering and Technology, 2009, 34 : 979 - 985
  • [6] Automatic segmentation of thigh magnetic resonance images
    Urricelqui, Lorena
    Malanda, Armando
    Villanueva, Arantxa
    World Academy of Science, Engineering and Technology, 2009, 58 : 531 - 537
  • [7] Automatic segmentation of thigh magnetic resonance images
    Urricelqui, Lorena
    Malanda, Armando
    Villanueva, Arantxa
    World Academy of Science, Engineering and Technology, 2009, 58 : 979 - 985
  • [8] Automatic landmarking of magnetic resonance brain images
    Izard, C
    Jedynak, BM
    Stark, CEL
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 1329 - 1340
  • [9] Automatic volumetric measurement of lateral ventricles on magnetic resonance images with correction of partial volume effects
    Barra, V
    Frenoux, E
    Boire, JY
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) : 16 - 22
  • [10] Partial volume correction of magnetic resonance spectroscopic imaging
    Lu, Yao
    Wu, Dee
    Magnotta, Vincent A.
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512