A high-resolution photon-counting breast CT system with tensor-framelet based iterative image reconstruction for radiation dose reduction

被引:17
作者
Ding, Huanjun [1 ]
Gao, Hao [2 ,3 ]
Zhao, Bo [1 ]
Cho, Hyo-Min [1 ]
Molloi, Sabee [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Math, Shanghai 200240, Peoples R China
关键词
tensor framelet; modulation transfer function; contrast-to-noise ratio; spatial resolution; high-resolution; COMPUTED-TOMOGRAPHY; BEAM CT; DETECTORS; FEASIBILITY; ALGORITHMS; CHIP; ART; MTF;
D O I
10.1088/0031-9155/59/20/6005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Both computer simulations and experimental phantom studies were carried out to investigate the radiation dose reduction with tensor framelet based iterative image reconstruction (TFIR) for a dedicated high-resolution spectral breast computed tomography (CT) based on a silicon strip photon-counting detector. The simulation was performed with a 10 cm-diameter water phantom including three contrast materials (polyethylene, 8 mg ml(-1) iodine and B-100 bone-equivalent plastic). In the experimental study, the data were acquired with a 1.3 cm-diameter polymethylmethacrylate (PMMA) phantom containing iodine in three concentrations (8, 16 and 32 mg ml(-1)) at various radiation doses (1.2, 2.4 and 3.6 mGy) and then CT images were reconstructed using the filtered-back-projection (FBP) technique and the TFIR technique, respectively. The image quality between these two techniques was evaluated by the quantitative analysis on contrast-to-noise ratio (CNR) and spatial resolution that was evaluated using the task-based modulation transfer function (MTF). Both the simulation and experimental results indicated that the task-based MTF obtained from TFIR reconstruction with one-third of the radiation dose was comparable to that from the FBP reconstruction for low contrast target. For high contrast target, the TFIR was substantially superior to the FBP reconstruction in terms of spatial resolution. In addition, TFIR was able to achieve a factor of 1.6-1.8 increase in CNR, depending on the target contrast level. This study demonstrates that the TFIR can reduce the required radiation dose by a factor of two-thirds for a CT image reconstruction compared to the FBP technique. It achieves much better CNR and spatial resolution for high contrast target in addition to retaining similar spatial resolution for low contrast target. This TFIR technique has been implemented with a graphic processing unit system and it takes approximately 10 s to reconstruct a single-slice CT image, which can potentially be used in a future multi-slit multi-slice spiral CT system.
引用
收藏
页码:6005 / 6017
页数:13
相关论文
共 40 条
  • [1] SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM
    ANDERSEN, AH
    KAK, AC
    [J]. ULTRASONIC IMAGING, 1984, 6 (01) : 81 - 94
  • [2] [Anonymous], P SPIE PHYS MED IMAG
  • [3] Large Area Photon Counting X-Ray Imaging Arrays for Clinical Dual-Energy Applications
    Barber, William C.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Wawrzyniak, Gregor
    Hartsough, Neal E.
    Gandhi, Thulasi
    Beck, Tom J.
    Taguchi, Ken
    Iwanczyk, Jan S.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3029 - +
  • [4] Computed tomography using the Medipix1 chip
    Bert, C
    Niederlöhner, D
    Giersch, J
    Pfeiffer, KF
    Anton, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) : 240 - 250
  • [5] High resolution X-ray imaging using a silicon strip detector
    Beuville, E
    Cahn, R
    Cederström, B
    Danielsson, M
    Hall, A
    Hasegawa, B
    Luo, L
    Lundqvist, M
    Nygren, D
    Oltman, E
    Walton, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3059 - 3063
  • [6] A Preliminary Investigation of Reduced-view Image Reconstruction from Low-dose Breast CT Data
    Bian, Junguo
    Han, Xiao
    Yang, Kai
    Sidky, Emil Y.
    Boone, John M.
    Pan, Xiaochuan
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [7] Experimental study of beam hardening artifacts in photon counting breast computed tomography
    Bisogni, M. G.
    Del Guerra, A.
    Lanconelli, N.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    Panetta, D.
    Pani, R.
    Quattrocchi, M. G.
    Randaccio, P.
    Rosso, V.
    Russo, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2) : 94 - 98
  • [8] Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment
    Boone, JM
    [J]. RADIOLOGY, 1999, 213 (01) : 23 - 37
  • [9] AN ANALYTICAL EDGE SPREAD FUNCTION MODEL FOR COMPUTER FITTING AND SUBSEQUENT CALCULATION OF THE LSF AND MTF
    BOONE, JM
    SEIBERT, JA
    [J]. MEDICAL PHYSICS, 1994, 21 (10) : 1541 - 1545
  • [10] Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study
    Bornefalk, Hans
    Danielsson, Mats
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) : 1999 - 2022