Behavior of fiber-reinforced polymer-reinforced anchorage zones for post-tensioned, concrete structures

被引:0
作者
Choi, MC [1 ]
Ibell, TJ
机构
[1] Jane Wernick Asociates, London, England
[2] Univ Bath, Dept Architecture & Civil Engn, Bath BA2 7AY, Avon, England
关键词
anchorage zones; fiber-reinforced polymer; post-tensioning;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to their corrosion resistance and strength-to-weight ratio, fiber-reinforced polymer (FRP) Materials have been suggested as an alternative to steel to be used in structural concrete. The relatively low stiffness of FRP compared with steel, implies that concrete structures containing FRP; ought to be prestressed. In this way, the serviceability of the structure is improved, and higher ultimate strength is attained Much research into FRP-prestressed concrete has now been conducted, but the design of FRP-reinforced post-tensioned anchorage zones (where the tendon force is transferred to the concrete) has received very little attention. The current research concentrates on investigating the, feasibility of using aramid FRP (AFRP) helical reinforcement in local anchorage zones for wholly non-metallic, efficient post-tensioned concrete structures. A total of 47 patch-loaded concrete specimens (of circular and rectangular cross section) have been tested and relevant results are provided herein. Laboratory-made AFRP has been used as reinforcement in a circular helical form. Test results are compared with predictions based on an existing design approach that has been modified for the case of FRP reinforcement. It is shown that the relative diametrical dimension between the reinforcing helix and the bearing plate is a critical factor, influencing the post-elastic behavior Further, by combining helical and mat reinforcing systems, both higher ultimate capacity and real ductility of the anchorage zones are achieved.
引用
收藏
页码:625 / 632
页数:8
相关论文
共 50 条
  • [21] Behavior of Externally Fiber-Reinforced Polymer Reinforced Shrinkage-Compensating Concrete Beams
    Cao, Qi
    Ma, Zhongguo John
    ACI STRUCTURAL JOURNAL, 2011, 108 (05) : 592 - 600
  • [22] Torsion Behavior of Concrete Beams Reinforced with Glass Fiber-Reinforced Polymer Bars and Stirrups
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2015, 112 (05) : 543 - 552
  • [23] Structural Behavior Evaluation of Reinforced Concrete Using the Fiber-Reinforced Polymer Strengthening Method
    Kim, Tae-Kyun
    Park, Jong-Sup
    Kim, Sang-Hyun
    Jung, Woo-Tai
    POLYMERS, 2021, 13 (05) : 1 - 18
  • [24] NUMERICAL STUDY ON ANCHORAGE ZONES OF POST-TENSIONED SLAB CONSIDERING ANCHORAGE DEVICE
    Ahmed, Nasser
    Metewally, Kamal
    INTERNATIONAL JOURNAL OF GEOMATE, 2020, 19 (74): : 123 - 130
  • [25] Post-tensioned anchorage zones with single straight concentric anchorages
    Sanders, DH
    Breen, JE
    ACI STRUCTURAL JOURNAL, 1997, 94 (02) : 146 - 158
  • [26] Flexural Cracks in Fiber-Reinforced Concrete Beams with Fiber-Reinforced Polymer Reinforcing Bars
    Lee, Won K.
    Jansen, Daniel C.
    Berlin, Kenneth B.
    Cohen, Ian E.
    ACI STRUCTURAL JOURNAL, 2010, 107 (03) : 321 - 329
  • [27] Active Protection of Fiber-Reinforced Polymer-Wrapped Reinforced Concrete Structures Against Corrosion
    Gadve, S.
    Mukherjee, A.
    Malhotra, S. N.
    CORROSION, 2011, 67 (02) : 0250021 - 02500211
  • [28] Post-heating behavior of concrete beams reinforced with fiber reinforced polymer bars
    Irshidat, Mohammad R.
    Haddad, Rami H.
    Almahmoud, Hanadi
    STRUCTURAL ENGINEERING AND MECHANICS, 2015, 53 (06) : 1253 - 1269
  • [29] Fatigue Behavior of Carbon Fiber-Reinforced Polymer-Repaired Corroded Reinforced Concrete Beams
    Loo, Kam Yoke M.
    Foster, Stephen J.
    Smith, Scott T.
    ACI STRUCTURAL JOURNAL, 2012, 109 (06) : 795 - 803
  • [30] Improvement of Anchorage Performance of Carbon Fiber-Reinforced Polymer Cables
    Kim, Tae-Kyun
    Jung, Woo-Tai
    POLYMERS, 2022, 14 (06)