Importance of flow division on transition to turbulence within an arteriovenous graft

被引:32
作者
Lee, Sang-Wook
Smith, David S.
Loth, Francis
Fischer, Paul F.
Bassiouny, Hisham S.
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL 60607 USA
[3] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[4] Argonne Natl Lab, Div Math & Comp Sci, Argonne, IL 60439 USA
[5] Univ Chicago, Dept Surg, Chicago, IL 60637 USA
关键词
arteriovenous graft; direct numerical simulation; transition to turbulence; flow division; hemodynamics;
D O I
10.1016/j.jbiomech.2006.03.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Transitional blood flow in an arteriovenous graft under various conditions of flow division was examined through direct numerical simulation. This junction consists of an inlet vessel (prosthetic graft) connected to a host vessel (vein) at an acute angle (21.6 degrees). Inlet Reynolds numbers, based on mean velocity and graft inlet diameter, ranged from 800 to 1400. Various flow divisions between the two ends of the host vessel (i.e., the proximal venous segment, PVS, and distal venous segment, DVS) were considered (PVS:DVS ratios of 100:0, 85:15, 70:30 and 115:(15)). The numerical technique employed the spectral element method which is a high-order discretization ideally suited to the simulation of transitional flows in complex domains. High velocity and pressure fluctuations were observed for the PVS:DVS = 70:30 and 85:15 cases and absent from the 100:0 and 115:(15) cases; the results indicate the importance of flow division on the development of turbulence in this junction. Transition to turbulence was observed at Reynolds numbers as low as 1000 and 800 under flow divisions of 85:15 and 70:30, respectively, significantly lower than the critical value of 2100. The frequency spectra of velocity fluctuations indicated a significant intensity within the frequency range of similar to 300 Hz downstream of the junction. An adverse pressure gradient developed in the PVS when graft inflow divided into opposite directions in the junction. This pressure gradient had a destabilizing effect on the flow and enhanced transition to turbulence in the PVS. These findings suggest that measurements of in vivo flow rates at the inlet and outlets are critical for the accurate prediction of arteriovenous hemodynamics. A potential clinical application of these results might be to close off the DVS during graft construction to ensure a 100:0 flow division. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:981 / 992
页数:12
相关论文
共 31 条
  • [1] BROSSOLLET LJ, 1992, THESIS GEORGIA I TEC
  • [2] CRAWSHAW HM, 1980, ARCH SURG-CHICAGO, V115, P1280
  • [3] DAVIES PF, 1986, P NATL ACAD SCI USA, V83, P2114, DOI 10.1073/pnas.83.7.2114
  • [4] Steady flow separation patterns in a 45 degree junction
    Ethier, CR
    Prakash, S
    Steinman, DA
    Leask, RL
    Couch, GG
    Ojha, M
    [J]. JOURNAL OF FLUID MECHANICS, 2000, 411 : 1 - 38
  • [5] GRAFT GEOMETRY AND VENOUS INTIMAL-MEDIAL HYPERPLASIA IN ARTERIOVENOUS LOOP GRAFTS
    FILLINGER, MF
    REINITZ, ER
    SCHWARTZ, RA
    RESETARITS, DE
    PASKANIK, AM
    BRUCH, D
    BREDENBERG, CE
    [J]. JOURNAL OF VASCULAR SURGERY, 1990, 11 (04) : 556 - 566
  • [6] Spectral Element Methods for Transitional Flows in Complex Geometries
    Fischer, Paul F.
    Kruse, Gerald W.
    Loth, Francis
    [J]. JOURNAL OF SCIENTIFIC COMPUTING, 2002, 17 (1-4) : 81 - 98
  • [7] FISCHER PF, 2005, P PAR CFD U MARYL MD
  • [8] An experimental. investigation of planar countercurrent turbulent shear layers
    Forliti, DJ
    Tang, BA
    Strykowski, PJ
    [J]. JOURNAL OF FLUID MECHANICS, 2005, 530 : 241 - 264
  • [9] Effects of geometry and flow division on flow structures in models of the distal end-to-side anastomosis
    Hughes, PE
    How, TV
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (07) : 855 - 872
  • [10] INVIVO DEMONSTRATION OF FLOW RECIRCULATION AND TURBULENCE DOWNSTREAM OF GRADED STENOSES IN CANINE ARTERIES
    HUTCHISON, KJ
    KARPINSKI, E