Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent Faults

被引:16
作者
Shen, Qinmu [1 ]
Lv, Kehong [1 ]
Liu, Guanjun [1 ]
Qiu, Jing [1 ]
机构
[1] Natl Univ Def Technol, Coll Mechatron Engn & Automat, Sci & Technol Integrated Logist Support Lab, Changsha 410073, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrical connector; electrical contact resistance; high-speed signal; intermittent fault; on-line diagnosis; FRETTING CORROSION;
D O I
10.1109/ACCESS.2017.2679223
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical connectors are widely used in many kinds of main equipment. It is very difficult, costly, and time consuming for the off-line diagnosis of intermittent faults (IFs) in connectors. To realize the on-line diagnosis by the traditional method, the voltage drop between two ends of the connector should be measured continuously at a high sample rate. This continuous measurement requires enormous testing resources, which is impractical in engineering fields. To solve this problem, this paper proposes an on-line diagnosis method in condition of the single-end test for the electrical connector IFs. To determine the fault threshold of the electrical contact resistance (ECR), first the impact of the ECR on high-speed transmission is studied, and then the connector fault feature in condition of the single-end test, which is called the insertion loss increment (ILI), is extracted. The measurement method of the ILI is also presented. Based on the above analysis, an ILI-based on-line diagnosis method for the connector IFs is specified. According to the qualitative and quantitative tests, the proposed diagnosis method is verified. The verification results show that the cumulative insertion loss increment, which is calculated from the ILI can truly exhibit the variation of ECR, and the error of the ILI-based diagnosis method is only about 1%.
引用
收藏
页码:4221 / 4232
页数:12
相关论文
共 41 条
[1]   TIME DISTRIBUTION OF INTERMITTENTS VERSUS CONTACT RESISTANCE FOR TIN TIN CONNECTOR INTERFACES DURING LOW AMPLITUDE MOTION [J].
ABBOTT, WH .
IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1984, 7 (01) :107-111
[2]   Simulation of high-speed interconnects [J].
Achar, R ;
Nakhla, MS .
PROCEEDINGS OF THE IEEE, 2001, 89 (05) :693-728
[3]   Intermittent Fault Location in Distribution Feeders [J].
Alamuti, Mohsen Mohammadi ;
Nouri, Hassan ;
Ciric, Rade M. ;
Terzija, Vladimir .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (01) :96-103
[4]   Intermittent Electrical Contact Resistance as a Contributory Factor in the Loss of Automobile Speed Control Functional Integrity [J].
Anderson, Antony F. .
IEEE ACCESS, 2014, 2 :258-289
[5]  
[Anonymous], 2007, THESIS
[6]   SURVEY OF CONTACT FRETTING IN ELECTRICAL CONNECTORS [J].
ANTLER, M .
IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1985, 8 (01) :87-104
[7]  
Antler M., 1984, P 34 EL COMP C NEW O, P343
[8]  
Artishchev S. A., 2013, 2013 23rd International Crimean Conference "Microwave & Telecommunication Technology" (CriMiCo), P1018
[9]  
Aukland N, 1995, ELECTRICAL CONTACTS - 1995: PROCEEDINGS OF THE FORTY-FIRST IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, P52, DOI 10.1109/HOLM.1995.482860
[10]  
Ballas M, 2011, IEEE AUTOTESTCON, P78, DOI 10.1109/AUTEST.2011.6058774