Walking speed estimation using foot-mounted inertial sensors: Comparing machine learning and strap-down integration methods

被引:53
作者
Mannini, Andrea [1 ]
Sabatini, Angelo Maria [1 ]
机构
[1] BioRobot Inst, Scuola Super St Anna, Pisa, Italy
关键词
Inertial sensing; Walking speed estimation; Hidden Markov models; Strap down integration; SPATIOTEMPORAL PARAMETERS; TRIAXIAL ACCELEROMETER; GAIT PARAMETERS; RECOGNITION;
D O I
10.1016/j.medengphy.2014.07.022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we implemented machine learning (ML) and strap-down integration (SDI) methods and analyzed them for their capability of estimating stride-by-stride walking speed. Walking speed was computed by dividing estimated stride length by stride time using data from a foot mounted inertial measurement unit. In SDI methods stride-by-stride walking speed estimation was driven by detecting gait events using a hidden Markov model (HMM) based method (HMM-based SDI); alternatively, a threshold-based gait event detector was investigated (threshold-based SDI). In the ML method a linear regression model was developed for stride length estimation. Whereas the gait event detectors were a priori fixed without training, the regression model was validated with leave-one-subject-out cross-validation. A subject-specific regression model calibration was also implemented to personalize the ML method. Healthy adults performed over-ground walking trials at natural, slower-than-natural and faster-than-natural speeds. The ML method achieved a root mean square estimation error of 2.0% and 4.2%, with and without personalization, against 2.0% and 3.1% by HMM-based SDI and threshold-based SDI. In spite that the results achieved by the two approaches were similar, the ML method, as compared with SDI methods, presented lower intra-subject variability and higher inter-subject variability, which was reduced by personalization. (C) 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1312 / 1321
页数:10
相关论文
共 38 条
[1]   ESTIMATION OF SPEED AND INCLINE OF WALKING USING NEURAL-NETWORK [J].
AMINIAN, K ;
ROBERT, P ;
JEQUIER, E ;
SCHUTZ, Y .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (03) :743-746
[2]   Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes [J].
Aminian, K ;
Najafi, B ;
Büla, C ;
Leyvraz, PF ;
Robert, P .
JOURNAL OF BIOMECHANICS, 2002, 35 (05) :689-699
[3]   WALKING SPEED AS A BASIS FOR NORMAL AND ABNORMAL GAIT MEASUREMENTS [J].
ANDRIACCHI, TP ;
OGLE, JA ;
GALANTE, JO .
JOURNAL OF BIOMECHANICS, 1977, 10 (04) :261-268
[4]  
[Anonymous], MED BIOL ENG COMPUT
[5]   Gait phase analysis based on a Hidden Markov Model [J].
Bae, Joonbum ;
Tomizuka, Masayoshi .
MECHATRONICS, 2011, 21 (06) :961-970
[6]   Gait analysis using a shoe-integrated wireless sensor system [J].
Bamberg, Stacy J. Morris ;
Benbasat, Ari Y. ;
Scarborough, Donna Moxley ;
Krebs, David E. ;
Paradiso, Joseph A. .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (04) :413-423
[7]   Walking speed estimation using shank-mounted accelerometers [J].
Bishop, E. ;
Li, Q. .
2010 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2010, :5096-5101
[8]   Validity of the prosthetic activity monitor to assess the duration and spatio-temporal characteristics of prosthetic walking [J].
Bussmann, JBJ ;
Culhane, KM ;
Horemans, HLD ;
Lyons, GM ;
Stam, HJ .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2004, 12 (04) :379-386
[9]  
Chen M, 2007, PROCEEDINGS OF THE 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOINFORMATICS AND BIOENGINEERING, VOLS I AND II, P517
[10]  
Ferraris F., 1995, Sensors and Materials, V7, P311