Cardiovascular magnetic resonance: Myocardial perfusion

被引:28
作者
Nagel, E
Al-Saadi, N
Fleck, E
机构
[1] German Heart Inst, Dept Internal Med Cardiol, D-13353 Berlin, Germany
[2] Humboldt Univ, Charite, D-1086 Berlin, Germany
关键词
magnetic resonance imaging; myocardial perfusion; ischemic heart disease;
D O I
10.1007/s000590050033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is growing evidence that the noninvasive assessment of myocardial perfusion with cardiovascular magnetic resonance is a valid and accurate tool for the assessment of ischemic heart disease and its introduction into routine clinical evaluation of patients is rapidly expected. Magnetic resonance measurements allow the evaluation of reversible and irreversible myocardial ischemia, the assessment of acute myocardial infarction, as well as the recognition and detection of viable myocardium. Magnetic resonance perfusion measurements are mainly performed with TI-shortening contrast agents such as gadolinium-DTPA either by visual analysis or based on the analyses of signal intensity time curves. For the detection of myocardial ischemia the first pass kinetics of a gadolinium-DTPA bolus and for the detection of myocardial necrosis and the definition of viable myocardium steady state distribution kinetics are assessed. Quantitative analysis of myocardial perfusion can be performed but requires complex modeling due to the characteristics of gadolinium-DTPA. Thus, semi-quantitative parameters are preferred. There is accumulating evidence in the literature that magnetic resonance imaging can be used for the detection of coronary artery stenosis with high diagnostic accuracy both with semi-quantitative or visual analysis. Myocardial infarction can be reliably detected and the infarcted area determined. Non-reperfused infarcted myocardium can be differentiated from reperfused myocardium by different enhancement patterns that correlates with viability. Cardiac magnetic resonance is a promising technique that can combine different functional studies during one examination, such as the assessment of wall motion and perfusion at rest and stress. With further improvements in analysis software magnetic resonance perfusion measurement may rapidly become a routine tool for the assessment of patients with coronary artery disease.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 94 条
[11]   A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging [J].
Cullen, JHS ;
Horsfield, MA ;
Reek, CR ;
Cherryman, GR ;
Barnett, DB ;
Samani, NJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) :1386-1394
[12]  
de Roos A, 1991, Magn Reson Q, V7, P191
[13]   ASSESSMENT OF CORONARY-ARTERY DISEASE SEVERITY BY POSITRON EMISSION TOMOGRAPHY - COMPARISON WITH QUANTITATIVE ARTERIOGRAPHY IN 193 PATIENTS [J].
DEMER, LL ;
GOULD, KL ;
GOLDSTEIN, RA ;
KIRKEEIDE, RL ;
MULLANI, NA ;
SMALLING, RW ;
NISHIKAWA, A ;
MERHIGE, ME .
CIRCULATION, 1989, 79 (04) :825-835
[14]   Validation of low-dose dobutamine magnetic resonance imaging for assessment of myocardial viability after infarction by serial imaging [J].
Dendale, P ;
Franken, PR ;
Holman, E ;
Avenarius, J ;
van der Wall, EE ;
de Roos, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (03) :375-+
[15]   REPERFUSED AND NONREPERFUSED MYOCARDIAL-INFARCTION - DIAGNOSTIC POTENTIAL OF GD-DTPA-ENHANCED MR IMAGING [J].
DEROOS, A ;
VANROSSUM, AC ;
VANDERWALL, E ;
POSTEMA, S ;
DOORNBOS, J ;
MATHEIJSSEN, N ;
VANDIJKMAN, PRM ;
VISSER, FC ;
VANVOORTHUISEN, AE .
RADIOLOGY, 1989, 172 (03) :717-720
[16]   QUANTIFICATION OF MYOCARDIAL BLOOD-FLOW AND EXTRACELLULAR VOLUMES USING A BOLUS INJECTION OF GD-DTPA - KINETIC MODELING IN CANINE ISCHEMIC DISEASE [J].
DIESBOURG, LD ;
PRATO, FS ;
WISENBERG, G ;
DROST, DJ ;
MARSHALL, TP ;
CARROLL, SE ;
ONEILL, B .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :239-253
[17]   Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI [J].
Ding, SJ ;
Wolff, SD ;
Epstein, FH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :514-519
[18]   MR IMAGING OF THE MYOCARDIUM USING NONIONIC CONTRAST-MEDIUM - SIGNAL-INTENSITY CHANGES IN PATIENTS WITH SUBACUTE MYOCARDIAL-INFARCTION [J].
DULCE, MC ;
DUERINCKX, AJ ;
HARTIALA, J ;
CAPUTO, GR ;
OSULLIVAN, M ;
CHEITLIN, MD ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :963-970
[19]   ISCHEMIC-HEART-DISEASE - ASSESSMENT WITH GADOLINIUM-ENHANCED ULTRAFAST MR-IMAGING AND DIPYRIDAMOLE STRESS [J].
EICHENBERGER, AC ;
SCHUIKI, E ;
KOCHLI, VD ;
AMANN, FW ;
MCKINNON, GC ;
VONSCHULTHESS, GK .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :425-431
[20]   Quantification of gadolinium-DTPA concentrations for different inversion times using an IR-turbo flash pulse sequence: A study on optimizing multislice perfusion imaging [J].
Fritz-Hansen, T ;
Rostrup, E ;
Ring, PB ;
Larsson, HBW .
MAGNETIC RESONANCE IMAGING, 1998, 16 (08) :893-899