Experimental study on the electrical and thermal characteristics of a hybrid photovoltaic/thermal water solar collector model using photovoltaic solar modules of different brands

被引:16
作者
Alexis, Lontsi Kuefouet [1 ]
Kewir, Tangka Julius [1 ]
Merlain, Djousse Kanouo Boris [1 ]
Bertholt, Sogang Segning Harry [1 ]
机构
[1] Univ Dschang, Rural Engn Dept, Renewable Energy Res Unit, FASA, POB 222, Dschang, Cameroon
关键词
PV/T hybrid solar system; Efficiency; Energy gain; Hot water temperature; Solar module brand; AIR-FLOW; PERFORMANCE; SYSTEM;
D O I
10.1016/j.ecmx.2022.100198
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, the results of an experimental study on the thermal and electrical behavior of this hybrid collector model allowed us to determine the electrical and thermal characteristics of water-based PV/T collectors in the climatic conditions of the western region of Cameroon. A prototype was made with monocrystalline solar modules from Canadian solar brands; Trina Solar and Felicity Solar. Tests were carried out and the data collected led us to optimize the electrical and thermal production of photovoltaic solar modules. We obtained an average daily electrical energy gain of 12.3% or 42Wc (Canadian Solar); 11.8% or 35.99Wc (Trina Solar) and 11.1% or 26.5Wc (Felicity Solar) compared to conventional solar module. On the thermal side, we obtained an average daily thermal power of 659.88 W or 12 L of hot water with a temperature of 41 degrees C for the Canadian Solar module; 659.89 W or 12 L of hot water with a temperature of 41.5 degrees C for the Trina Solar module and 538.38 W or 10 L of hot water with a temperature of 41 degrees C for the Felicity solar module. These tests were carried out on an average solar irradiation of 877.88 W/m(2) between 8:05 am and 3:30 pm. This approach allowed us to recover an amount of the electrical power of the modules lost as heat while determining the amount of hot water that can be produced by a PV module. This prototype was produced and experimented with. It also allowed us to observe that the performance of PV/T water systems also varies depending on the brand of solar module chosen.
引用
收藏
页数:8
相关论文
共 23 条
[1]   Investigation of Solar Photovoltaic-Thermal (PVT) and Solar Photovoltaic (PV) Performance: A Case Study in Ghana [J].
Abdul-Ganiyu, Saeed ;
Quansah, David A. ;
Ramde, Emmanuel W. ;
Seidu, Razak ;
Adaramola, Muyiwa S. .
ENERGIES, 2020, 13 (11)
[2]   Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq [J].
Amori, Karima E. ;
Al-Najjar, Hussein M. Taqi .
APPLIED ENERGY, 2012, 98 :384-395
[3]  
[Anonymous], 2016, 3 INT C ENERGY ALGER, V81, P500
[4]  
Bahaidarah HM, 2013, IEEE PHOT SPEC CONF, P2987, DOI 10.1109/PVSC.2013.6745090
[5]  
Boureima D, 2018, INDIAN J SCI TECHNOL, V11, P1
[6]  
Cheikh Ben, 2015, THESIS, pP59
[7]   Performance evaluation of photovoltaic-thermosyphon system for subtropical climate application [J].
Chow, T. T. ;
He, W. ;
Ji, J. ;
Chan, A. L. S. .
SOLAR ENERGY, 2007, 81 (01) :123-130
[8]   Hybrid photovoltaic-thermosyphon water heating system for residential application [J].
Chow, TT ;
He, W ;
Ji, J .
SOLAR ENERGY, 2006, 80 (03) :298-306
[9]   Industrial application of PV/T solar energy systems [J].
Kalogirou, S. A. ;
Tripanagnostopoulos, Y. .
APPLIED THERMAL ENGINEERING, 2007, 27 (8-9) :1259-1270
[10]  
Kapseu Cesar, 2013, ENERGIES RENOUVELABL, pP233