Determination of phenylurea herbicides in water samples using on-line sorptive preconcentration and high-performance liquid chromatography with UV of electrospray mass spectrometric detection

被引:34
作者
Baltussen, E [1 ]
Snijders, H [1 ]
Janssen, HG [1 ]
Sandra, P [1 ]
Cramers, CA [1 ]
机构
[1] Eindhoven Univ Technol, Instrumental Anal Lab, NL-5600 MB Eindhoven, Netherlands
关键词
water analysis; electrospray ionisation; preconcentration methods; mass spectrometry; pesticides; phenylureas;
D O I
10.1016/S0021-9673(97)01182-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A recently developed method for the extraction of organic micropollutants from aqueous samples based on sorptive enrichment in columns packed with 100% polydimethylsiloxane (PDMS) particles was coupled on-line with HPLC analysis. The sorptive enrichment procedure originally developed for relatively nonpolar analytes was used to preconcentrate polar phenylurea herbicides from aqueous samples. PDMS extraction columns of 5, 10 and 25 cm were used to extract the herbicides from distilled, tap and river water samples. A model that allows prediction of retention and breakthrough volumes is presented. Despite the essentially apolar nature of the PDMS material, it is possible to concentrate sample volumes up to 10 ml on PDMS cartridges without losses of the most polar analyte under investigation, fenuron. For less polar analytes significantly larger sample volumes can be applied. Since standard UV detection does not profiles ide adequate selectivity for river water samples, an electrospray (ES)-MS instrument was used to determine phenylurea herbicides in a water sample from the river Dommel, Methoxuron was present at a level of 80 ng/l. The detection limit of the current set-up, using 10 mi water samples and ES-MS detection is 10 ng/l in river water samples. Strategies for further improvement of the detection limits are identified. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:285 / 295
页数:11
相关论文
共 50 条
  • [21] Bioanalytical Method for the Determination of Hydroxyproline in Mouse Kidney by High-Performance Liquid Chromatography with Tandem Mass Spectrometric Detection
    Rika Shiota
    Hirotoshi Morita
    Tomoko Matsumoto
    Atsushi Morimoto
    Jun Hayakawa
    Masako Oka
    Hiroshi Kamimori
    Analytical Sciences, 2017, 33 : 719 - 722
  • [22] Determination of selected human pharmaceutical compounds in effluent and surface water samples by high-performance liquid chromatography-electrospray tandem mass spectrometry
    Hilton, MJ
    Thomas, KV
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) : 129 - 141
  • [23] Bioanalytical Method for the Determination of Hydroxyproline in Mouse Kidney by High-Performance Liquid Chromatography with Tandem Mass Spectrometric Detection
    Shiota, Rika
    Morita, Hirotoshi
    Matsumoto, Tomoko
    Morimoto, Atsushi
    Hayakawa, Jun
    Oka, Masako
    Kamimori, Hiroshi
    ANALYTICAL SCIENCES, 2017, 33 (06) : 719 - 722
  • [24] Determination of nine high-intensity sweeteners in various foods by high-performance liquid chromatography with mass spectrometric detection
    Zygler, Agata
    Wasik, Andrzej
    Kot-Wasik, Agata
    Namiesnik, Jacek
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (07) : 2159 - 2172
  • [25] Determination of gluconate in nuclear waste by high-performance liquid chromatography: comparison of pulsed amperometric detection and electrospray mass spectrometry detection
    Laurence du Bois de Maquillé
    Perrine Wund
    Laëtitia Renaudin
    Céline Gautier
    Alain Jardy
    Jérôme Vial
    Didier Thiébaut
    Pascal Fichet
    Florence Goutelard
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 306 : 213 - 220
  • [26] Extraction of maleic hydrazide residues from potato crisps and their determination using high-performance liquid chromatography with UV and atmospheric pressure chemical ionisation mass spectrometric detection
    Lewis, DJ
    Barnes, KA
    Wilkinson, K
    Thorpe, SA
    Reynolds, SL
    Startin, JR
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 391 - 396
  • [27] On-line dual-precolumn-based trace enrichment for the determination of polar and acidic microcontaminants in river water by liquid chromatography with diode-array UV and tandem mass spectrometric detection
    Hogenboom, AC
    Hofman, MP
    Jolly, DA
    Niessen, WMA
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) : 377 - 388
  • [28] Determination of gluconate in nuclear waste by high-performance liquid chromatography: comparison of pulsed amperometric detection and electrospray mass spectrometry detection
    de Maquille, Laurence du Bois
    Wund, Perrine
    Renaudin, Laetitia
    Gautier, Celine
    Jardy, Alain
    Vial, Jerome
    Thiebaut, Didier
    Fichet, Pascal
    Goutelard, Florence
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 306 (01) : 213 - 220
  • [29] Use of TiO2 nanotube arrays as the adsorbents for preconcentration of triazine herbicides in environmental water samples prior to determination using high performance liquid chromatography
    Zhou, Qingxiang
    Fang, Zhi
    ANALYTICAL METHODS, 2015, 7 (07) : 3277 - 3282
  • [30] Determination of benzoylureas in tomato by high-performance liquid chromatography using continuous on-line post-elution photoirradiation with fluorescence detection
    Martínez-Galera, M
    López-López, T
    Gil-García, MD
    Martínez-Vidal, JL
    Vázquez, PP
    JOURNAL OF CHROMATOGRAPHY A, 2001, 918 (01) : 79 - 85