Selectivity differences for C18 and C8 reversed-phase columns as a function of temperature and gradient steepness II.: Minimizing column reproducibility problems

被引:31
作者
Dolan, JW
Snyder, LR [1 ]
Blanc, T
机构
[1] LC Resources Inc, Walnut Creek, CA 94596 USA
[2] Ortho Biotech, Raritan, NJ 08869 USA
基金
美国国家卫生研究院;
关键词
stationary phases; LC; column reproducibility; gradient time; temperature; selectivity; method development;
D O I
10.1016/S0021-9673(00)00855-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The choice of T and t(G) as variables for controlling selectivity and resolution during reversed-phase liquid chromatography (RPLC) method development can be used to minimize problems caused by column batch-to-batch irreproducibility. When a new column fails to provide adequate separation of the sample, altered values of T and t(G) can be predicted that will restore the separation obtained with the previous column. Alternatively, columns from different manufacturers can be tested during method development, in order to find a common set of conditions (T and t(G)) that provide acceptable separation with two or more of these columns. In this way, any of several columns from different sources become usable for the method. Examples are shown of these different computer-assisted procedures for minimizing problems due to column variability. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:51 / 63
页数:13
相关论文
共 12 条
[1]  
[Anonymous], PHARMEUROPA
[2]   Selectivity differences for C18 and C8 reversed-phase columns as a function of temperature and gradient steepness I.: Optimizing selectivity and resolution [J].
Dolan, JW ;
Snyder, LR ;
Blanc, T ;
Van Heukelem, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 897 (1-2) :37-50
[3]   Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time III. Improving the accuracy of computer simulation [J].
Dolan, JW ;
Snyder, LR ;
Wolcott, RG ;
Haber, P ;
Baczek, T ;
Kaliszan, R ;
Sander, LC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :41-68
[4]  
FURMAN WB, 1998, PHARM TECHNOL JUN, P58
[5]   Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatographic columns II.: Results obtained with Symmetry C18 columns [J].
Kele, M ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (01) :55-79
[6]  
Majors RE, 1997, LC GC-MAG SEP SCI, V15, P1008
[7]  
MAJORS RE, 1991, LC GC-MAG SEP SCI, V9, P686
[8]   Universal procedure for the assessment of the reproducibility and the classification of silica-based reversed-phase packings - II. Classification of reversed-phase packings [J].
Neue, UD ;
Alden, BA ;
Walter, TH .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (01) :101-116
[9]  
Proctor KG., 1996, CHEM MODIFIED SURFAC, P45
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COMPUTER-SIMULATION BASED ON A RESTRICTED MULTIPARAMETER APPROACH .2. APPLICATIONS [J].
SNYDER, LR ;
DOLAN, JW ;
LOMMEN, DC .
JOURNAL OF CHROMATOGRAPHY, 1990, 535 (1-2) :75-92