A practical method of measuring glomerular filtration rate by Iohexol clearance using dried capillary blood spots

被引:19
|
作者
Mafham, Marion M.
Niculescu-Duvaz, Ioana
Barron, Jeffrey
Emberson, Jonathan R.
Dockrell, Mark E. C.
Landray, Martin J.
Baigent, Colin
机构
[1] Clin Trial Serv Unit, Oxford OX3 7LF, England
[2] Clin Trial Serv Unit, Renal Studies Grp, Oxford, England
[3] St Helier Hosp, S W Thames Inst Renal Res, Carshalton SM5 1AA, Surrey, England
来源
NEPHRON CLINICAL PRACTICE | 2007年 / 106卷 / 03期
关键词
creatinine; calculated creatinine clearance; glomerular filtration rate; iohexol; SERUM CYSTATIN-C; COCKCROFT-GAULT EQUATIONS; RENAL-DISEASE; BIOLOGICAL VARIATION; PREDICTION EQUATION; PLASMA-CLEARANCE; KIDNEY-FUNCTION; CREATININE; PERFORMANCE; SINGLE;
D O I
10.1159/000102997
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Exogenous tracer-based methods of measuring glomerular filtration rate (GFR) are difficult to perform, whilst creatinine-based estimation formulae are inaccurate. Methods: We assessed a new technique of measuring iohexol clearance using timed dried capillary blood spots. A reference GFR was measured in 81 subjects (GFR 15 - 124 ml/ min/1.73 m(2)) by iohexol clearance using three venous samples (2, 3 and 4 h after an intravenous bolus). GFR was estimated by six test methods; iohexol clearance using (i) 3 blood spots (2, 3, 4 h); (ii) 2 blood spots (2, 4 h) and (iii) 1 blood spot ( 4 h); (iv) the Modification of Diet in Renal Disease (MDRD) formula; ( v) the Cockcroft-Gault formula, and ( vi) a formula estimating GFR from serum cystatin C concentration. For each test method the bias and precision were calculated as the mean and standard deviation (SD) of the 'GFR differences' ( test method GFR - reference GFR). Results: The limits of agreement (bias +/- 1.96 x SD; in ml/min/1.73 m(2)) were: ( i) 1.1 +/- 15.1 for 3-spot iohexol clearance; ( ii) 0.6 +/- 14.9 for 2-spot iohexol clearance; ( iii) 4.5 +/- 21.2 for 1-spot iohexol clearance; ( iv) - 15.7 +/- 33.3 for the MDRD formula; ( v) - 9.6 +/- 32.9 for the Cockcroft-Gault formula, and ( vi) - 12.1 +/- 31.7 for the Cystatin C formula. The accuracy of all six test methods was similar among individuals with GFR < 60 ml/min/ 1.73 m(2); however, in individuals with GFR >= 60 ml/min/ 1.73 m(2), the MDRD, Cockcroft-Gault and Cystatin C formulae were all imprecise and systematically underestimated GFR. Conclusions: Blood spot iohexol clearance provides a potentially practical method of estimating GFR accurately in large-scale epidemiological studies especially among individuals without established chronic kidney disease. Copyright (c) 2007 S. Karger AG, Basel.
引用
收藏
页码:104 / 112
页数:9
相关论文
共 50 条
  • [31] Glomerular filtration rate evaluation in the dog throughout the plasmatic clearance of iohexol: Simplified methods
    Lippi, Ilaria
    Meucci, Valentina
    Guidi, Grazia
    Soldani, Giulio
    VETERINARIA, 2008, 22 (01): : 53 - +
  • [32] Iohexol Clearance for Determination of Glomerular Filtration Rate in Rats Induced to Acute Renal Failure
    Passos, Michelle T.
    Nishida, Sonia K.
    Camara, Niels O. S.
    Shimizu, Maria Heloisa
    Mastroianni-Kirsztajn, Gianna
    PLOS ONE, 2015, 10 (04):
  • [33] Reliability of glomerular filtration rate estimating formulas compared to iohexol plasma clearance in critically ill children
    Evelyn Dhont
    Charlotte Windels
    Evelien Snauwaert
    Tatjana Van Der Heggen
    Annick de Jaeger
    Laura Dhondt
    Joris Delanghe
    Siska Croubels
    Johan Vande Walle
    Peter De Paepe
    Pieter A. De Cock
    European Journal of Pediatrics, 2022, 181 : 3851 - 3866
  • [34] Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors
    Jin, Zhicheng
    Huang, Rongrong
    Christensen, Paul
    Bertholf, Roger L.
    Yi, Xin
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [35] A practical approach to glomerular filtration rate measurements: Creatinine clearance estimation using cimetidine
    Serdar, MA
    Kurt, I
    Ozcelik, F
    Urhan, M
    Ilgan, S
    Yenicesu, M
    Kenar, L
    Kutluay, T
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2001, 31 (03) : 265 - 273
  • [36] Glomerular filtration rate determined by measuring serum clearance of iohexol in unanesthetized cheetahs (Acinonyx jubatus) with comparison to serum symmetric dimethylarginine
    Lordi, Nicholas
    Bapodra-Villaverde, Priya
    Flint, Mark
    PLOS ONE, 2024, 19 (10):
  • [37] Assessment of glomerular filtration rate measurement in dogs using dynamic contrast CT compared to serum iohexol clearance
    Kaenkangploo, Duangdaun
    Kampa, Naruepon
    Jitpean, Supranee
    Seesupa, Suvaluk
    Yongvanit, Karn
    VETERINARY RADIOLOGY & ULTRASOUND, 2022, 63 (01) : 38 - 46
  • [38] Development of a nonisotopic capillary electrophoresis-based method for measuring glomerular filtration rate
    Bergert, JH
    Liedtke, RR
    Oda, RP
    Landers, JP
    Wilson, DM
    ELECTROPHORESIS, 1997, 18 (10) : 1827 - 1835
  • [39] IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD
    BROWN, SCW
    OREILLY, PH
    JOURNAL OF UROLOGY, 1991, 146 (03) : 675 - 679
  • [40] Measurement of glomerular filtration rate: Internal and external validations of the iohexol plasma clearance technique by HPLC
    Luis-Lima, Sergio
    Gaspari, Flavio
    Porrini, Esteban
    Garcia-Gonzalez, Martin
    Batista, Norberto
    Bosa-Ojeda, Francisco
    Oramas, Juana
    Carrara, Fabiola
    Manuel Gonzalez-Posada, Jose
    Marrero, Domingo
    Salido, Eduardo
    Torres, Armando
    Jimenez-Sosa, Alejandro
    CLINICA CHIMICA ACTA, 2014, 430 : 84 - 85