A practical method of measuring glomerular filtration rate by Iohexol clearance using dried capillary blood spots

被引:19
|
作者
Mafham, Marion M.
Niculescu-Duvaz, Ioana
Barron, Jeffrey
Emberson, Jonathan R.
Dockrell, Mark E. C.
Landray, Martin J.
Baigent, Colin
机构
[1] Clin Trial Serv Unit, Oxford OX3 7LF, England
[2] Clin Trial Serv Unit, Renal Studies Grp, Oxford, England
[3] St Helier Hosp, S W Thames Inst Renal Res, Carshalton SM5 1AA, Surrey, England
来源
NEPHRON CLINICAL PRACTICE | 2007年 / 106卷 / 03期
关键词
creatinine; calculated creatinine clearance; glomerular filtration rate; iohexol; SERUM CYSTATIN-C; COCKCROFT-GAULT EQUATIONS; RENAL-DISEASE; BIOLOGICAL VARIATION; PREDICTION EQUATION; PLASMA-CLEARANCE; KIDNEY-FUNCTION; CREATININE; PERFORMANCE; SINGLE;
D O I
10.1159/000102997
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Exogenous tracer-based methods of measuring glomerular filtration rate (GFR) are difficult to perform, whilst creatinine-based estimation formulae are inaccurate. Methods: We assessed a new technique of measuring iohexol clearance using timed dried capillary blood spots. A reference GFR was measured in 81 subjects (GFR 15 - 124 ml/ min/1.73 m(2)) by iohexol clearance using three venous samples (2, 3 and 4 h after an intravenous bolus). GFR was estimated by six test methods; iohexol clearance using (i) 3 blood spots (2, 3, 4 h); (ii) 2 blood spots (2, 4 h) and (iii) 1 blood spot ( 4 h); (iv) the Modification of Diet in Renal Disease (MDRD) formula; ( v) the Cockcroft-Gault formula, and ( vi) a formula estimating GFR from serum cystatin C concentration. For each test method the bias and precision were calculated as the mean and standard deviation (SD) of the 'GFR differences' ( test method GFR - reference GFR). Results: The limits of agreement (bias +/- 1.96 x SD; in ml/min/1.73 m(2)) were: ( i) 1.1 +/- 15.1 for 3-spot iohexol clearance; ( ii) 0.6 +/- 14.9 for 2-spot iohexol clearance; ( iii) 4.5 +/- 21.2 for 1-spot iohexol clearance; ( iv) - 15.7 +/- 33.3 for the MDRD formula; ( v) - 9.6 +/- 32.9 for the Cockcroft-Gault formula, and ( vi) - 12.1 +/- 31.7 for the Cystatin C formula. The accuracy of all six test methods was similar among individuals with GFR < 60 ml/min/ 1.73 m(2); however, in individuals with GFR >= 60 ml/min/ 1.73 m(2), the MDRD, Cockcroft-Gault and Cystatin C formulae were all imprecise and systematically underestimated GFR. Conclusions: Blood spot iohexol clearance provides a potentially practical method of estimating GFR accurately in large-scale epidemiological studies especially among individuals without established chronic kidney disease. Copyright (c) 2007 S. Karger AG, Basel.
引用
收藏
页码:104 / 112
页数:9
相关论文
共 50 条
  • [21] Simplified Iohexol-Based Method for Measurement of Glomerular Filtration Rate in Goats and Pigs
    van Gelder, Maaike K.
    Stevens, Jasper
    Pieters, Tobias T.
    Vaessen, Koen R. D.
    Joles, Jaap A.
    Verhaar, Marianne C.
    Gerritsen, Karin G. F.
    BIOLOGY-BASEL, 2021, 10 (06):
  • [22] A Bayesian approach to assess glomerular filtration rate (GFR) using plasma iohexol clearance in renal transplant recipients
    Benz-De Bretagne, I.
    Blasco, H.
    Gatault, P.
    Barbet, C.
    Buechler, M.
    Andres, C. R.
    Halimi, J. M.
    Le Guellec, C.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2014, 28 : 20 - 20
  • [23] Iohexol Clearance for Determination of Glomerular Filtration Rate in Cynomolgus Monkeys (Macaca fascicularis)
    Zhang, Changqing
    Ding, Shanshan
    Fang, Yupeng
    Zhang, Li
    Hu, Weimin
    Lu, Jinlian
    Jing, Tao
    Tao, Yi
    Zhang, Xin
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2017, 56 (03): : 330 - 333
  • [24] PLASMA-CLEARANCE OF NONRADIOACTIVE IOHEXOL AS A MEASURE OF GLOMERULAR-FILTRATION RATE
    GASPARI, F
    PERICO, N
    RUGGENENTI, P
    MOSCONI, L
    AMUCHASTEGUI, CS
    GUERINI, E
    DAINA, E
    REMUZZI, G
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (02): : 257 - 263
  • [25] Evaluation of glomerular filtration rate estimation through plasma clearance of iohexol in seagulls (Larus michahellis)
    Vernaccini, Matilde
    Sgorbini, Micaela
    De Marchi, Lucia
    Pacini, Maria Irene
    Ceccherelli, Renato
    Scaletti, Leonardo Gaci
    Bonelli, Francesca
    Meucci, Valentina
    BMC VETERINARY RESEARCH, 2025, 21 (01)
  • [26] COMPARATIVE-EVALUATION OF IOHEXOL AND INULIN-CLEARANCE FOR GLOMERULAR-FILTRATION RATE DETERMINATIONS
    LINDBLAD, HG
    BERG, UB
    ACTA PAEDIATRICA, 1994, 83 (04) : 418 - 422
  • [27] THE CLEARANCE OF IOHEXOL AS A MEASURE OF THE GLOMERULAR-FILTRATION RATE IN CHILDREN WITH CHRONIC-RENAL-FAILURE
    STAKE, G
    MONN, E
    ROOTWELT, K
    MONCLAIR, T
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (08) : 729 - 734
  • [28] Using a three-compartment model improves the estimation of iohexol clearance to assess glomerular filtration rate
    Taubert, Max
    Ebert, Natalie
    Martus, Peter
    van der Giet, Markus
    Fuhr, Uwe
    Schaeffner, Elke
    SCIENTIFIC REPORTS, 2018, 8
  • [29] Volumetric absorptive microsampling to measure iohexol and creatinine concentrations for estimation of glomerular filtration rate in cats: aligning animal welfare with practical feasibility
    Hanna De Baets
    Marleen Brans
    Dominique Paepe
    Christophe P. Stove
    BMC Veterinary Research, 21 (1)
  • [30] A Method for Evaluating Robustness of Limited Sampling Strategies-Exemplified by Serum Iohexol Clearance for Determination of Measured Glomerular Filtration Rate
    Hovd, Markus
    Robertsen, Ida
    Woillard, Jean-Baptiste
    Asberg, Anders
    PHARMACEUTICS, 2023, 15 (04)