Dental Implant Navigation System Based on Trinocular Stereo Vision

被引:10
作者
Bi, Songlin [1 ]
Wang, Menghao [1 ]
Zou, Jiaqi [1 ]
Gu, Yonggang [2 ]
Zhai, Chao [2 ]
Gong, Ming [2 ]
机构
[1] Univ Sci & Technol China, Dept Precis Machinery & Precis Instrumentat, Hefei 230027, Peoples R China
[2] Univ Sci & Technol China, Expt Ctr Engn & Mat Sci, Hefei 230027, Peoples R China
关键词
dental implant; trinocular stereo vision; dynamic tracking; ACCURACY; PLACEMENT; SURGERY;
D O I
10.3390/s22072571
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditional dental implant navigation systems (DINS) based on binocular stereo vision (BSV) have limitations, for example, weak anti-occlusion abilities, as well as problems with feature point mismatching. These shortcomings limit the operators' operation scope, and the instruments may even cause damage to the adjacent important blood vessels, nerves, and other anatomical structures. Trinocular stereo vision (TSV) is introduced to DINS to improve the accuracy and safety of dental implants in this study. High positioning accuracy is provided by adding cameras. When one of the cameras is blocked, spatial positioning can still be achieved, and doctors can adjust to system tips; thus, the continuity and safety of the surgery is significantly improved. Some key technologies of DINS have also been updated. A bipolar line constraint algorithm based on TSV is proposed to eliminate the feature point mismatching problem. A reference template with active optical markers attached to the jaw measures head movement. A T-type template with active optical markers is used to obtain the position and direction of surgery instruments. The calibration algorithms of endpoint, axis, and drill are proposed for 3D display of the surgical instrument in real time. With the preoperative path planning of implant navigation software, implant surgery can be carried out. Phantom experiments are carried out based on the system to assess the feasibility and accuracy. The results show that the mean entry deviation, exit deviation, and angle deviation are 0.55 mm, 0.88 mm, and 2.23 degrees, respectively.
引用
收藏
页数:15
相关论文
共 30 条
[1]   A Robust Recognition and Accurate Locating method for Circular Coded Diagonal Target [J].
Bao, Yunna ;
Shang, Yang ;
Sun, Xiaoliang ;
Zhou, Jiexin .
AOPC 2017: 3D MEASUREMENT TECHNOLOGY FOR INTELLIGENT MANUFACTURING, 2017, 10458
[2]   Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study [J].
Beretta, Mario ;
Poli, Pier Paolo ;
Maiorana, Carlo .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2014, 44 (04) :184-193
[3]   High Precision Optical Tracking System Based on near Infrared Trinocular Stereo Vision [J].
Bi, Songlin ;
Gu, Yonggang ;
Zou, Jiaqi ;
Wang, Lianpo ;
Zhai, Chao ;
Gong, Ming .
SENSORS, 2021, 21 (07)
[4]   Implant Placement Accuracy Using Dynamic Navigation [J].
Block, Michael S. ;
Emery, Robert W. ;
Lank, Kathryn ;
Ryan, James .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) :92-99
[5]   Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies [J].
Bover-Ramos, Fernando ;
Vina-Almunia, Jose ;
Cervera-Ballester, Juan ;
Penarrocha-Diago, Miguel ;
Garcia-Mira, Berta .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) :101-115
[6]   Accuracy of dental implant surgery with robotic position feedback and registration algorithm: An in-vitro study [J].
Cheng, Kang-jie ;
Kan, Tian-shu ;
Liu, Yun-feng ;
Zhu, Wei-dong ;
Zhu, Fu-dong ;
Wang, Wei-bin ;
Jiang, Xian-feng ;
Dong, Xing-tao .
COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 129
[7]   Incidental findings of implant complications on postimplantation CBCTs: A cross-sectional study [J].
Clark, Danielle ;
Barbu, Horia ;
Lorean, Adi ;
Mijiritsky, Eitan ;
Levin, Liran .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) :776-782
[8]   Current state of the art of computer-guided implant surgery [J].
D'haese, Jan ;
Ackhurst, Johan ;
Wismeijer, Daniel ;
De Bruyn, Hugo ;
Tahmaseb, Ali .
PERIODONTOLOGY 2000, 2017, 73 (01) :121-133
[9]  
[段康容 Duan Kangrong], 2010, [传感器与微系统, Transducer and Microsystem Technology], V29, P74
[10]   Robust line matching through line-point invariants [J].
Fan, Bin ;
Wu, Fuchao ;
Hu, Zhanyi .
PATTERN RECOGNITION, 2012, 45 (02) :794-805