Unsynchronized Fault-Location Scheme for Nonlinear HIF in Transmission Lines

被引:18
|
作者
Ibrahim, Doaa Khalil [1 ]
Eldin, El Sayed Tag [1 ]
Abou El-Zahab, Essam El-Din [1 ]
Saleh, Saber Mohamed [2 ]
机构
[1] Cairo Univ, Elect Power & Machines Dept, Fac Engn, Cairo 12613, Egypt
[2] Minist Elect & Energy, Helwan 12816, Egypt
关键词
Double-fed circuit; fault location; high impedance fault (HIF); PROTECTION; ALGORITHM; DISTANCE;
D O I
10.1109/TPWRD.2009.2036182
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The general aim of this paper is to develop an accurate fault-location scheme that can solve the problems affecting the accuracy of the existing conventional fault locators achieving easier maintenance and restoration time reduction as well as economical aims. This consequently helps to fit the new deregulation policies and competitive marketing. This investigation successfully applies zero-sequence current (3I(o)) from the two terminals for earth high impedance fault (HIF) location, or negative-sequence currents from the two terminals of one faulted phase for line-to-line fault location. The HIF location is determined within only a maximum time of one cycle. The proposed scheme is insensitive to variations of different parameters, such as fault type, HIF behavior, wide-range transmission-line parameters variation, and fault inception angle. Staged fault testing results demonstrate that the proposed algorithm has feasible performance.
引用
收藏
页码:631 / 637
页数:7
相关论文
共 50 条
  • [31] Distributed Traveling-Wave-Based Fault-Location Algorithm Embedded in Multiterminal Transmission Lines
    Ding, Jiali
    Wang, Xin
    Zheng, Yihui
    Li, Lixue
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (06) : 3045 - 3054
  • [32] New Fault-Location Algorithm for Transmission Lines Including Unified Power-Flow Controller
    Ahsaee, Mahdi Ghazizadeh
    Sadeh, Javad
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) : 1763 - 1771
  • [33] Unsynchronised fault-location technique for three-terminal lines
    Mahamedi, Behnam
    Sanaye-Pasand, Majid
    Azizi, Sadegh
    Zhu, Jian Guo
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (15) : 2099 - 2107
  • [34] Fault-Location Scheme for Power Distribution System with Distributed Generation
    Alwash, Shamam Fadhil
    Ramachandaramurthy, Vigna K.
    Mithulananthan, Nadarajah
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1187 - 1195
  • [35] Unsynchronized Fault Location Independent on Line Parameters for Transmission Systems
    Khater, Wagdy M.
    Elkalashy, Nagy I.
    Kawady, Tamer A.
    Taalab, Abdel-Maksoud I.
    Lehtonen, Matti
    2014 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT EUROPE), 2014,
  • [36] Noniterative Parameter-Free Fault Location for Practically Transposed Transmission Lines With Synchronized/Unsynchronized Measurements
    Lu, Dian
    Wan, Jun
    Duan, Mengzhao
    Xie, Yuhao
    Fan, Rui
    Liu, Yu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [37] A Novel Fault-location Method for HVDC Transmission Lines Based on Concentric Relaxation Principle and Wavelet Packet
    Li, Congshan
    He, Ping
    Wang, Feng
    Yang, Cunxiang
    Tao, Yukun
    Ji, Yuqi
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (05) : 705 - 716
  • [38] A transmission line fault-location system using the wavelet transform
    Hisakado, T
    Tanaka, K
    Okumura, K
    ELECTRICAL ENGINEERING IN JAPAN, 2002, 140 (04) : 27 - 37
  • [39] Fault location on series and shunt compensated lines using unsynchronized measurements
    Hussain, Shoaib
    Osman, A. H.
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 116 : 166 - 173
  • [40] An accurate unsynchronized fault location method on practically transposed transmission lines with closed-form solutions
    Lu, Dian
    Liu, Yu
    Xie, Yuhao
    Zhu, Yuxuan
    Fan, Rui
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155