A diamond target for megavoltage cone-beam CT

被引:18
|
作者
Sawkey, D. [1 ]
Lu, M. [1 ]
Morin, O. [1 ]
Aubin, M. [1 ]
Yom, S. S. [1 ]
Gottschalk, A. R. [1 ]
Bani-Hashemi, A. [2 ]
Faddegon, B. A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, Ctr Comprehens Canc, San Francisco, CA 94143 USA
[2] Siemens Healthcare Sector, Concord, CA 94520 USA
关键词
biomedical equipment; computerised tomography; diamond; dosimetry; linear accelerators; Monte Carlo methods; X-ray imaging; X-RAY-BEAMS; MONTE-CARLO; COMPUTED-TOMOGRAPHY; SIMULATION; SYSTEM; IMPLEMENTATION; LINE;
D O I
10.1118/1.3302831
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: A sintered diamond target was used in place of a graphite target as part of an imaging beam line (an unflattened beam from a graphite target) installed on a linear accelerator. The diamond target, with a greater density than the graphite target, permitted imaging at the lower beam energy (4 MV) required with the graphite target and the higher beam energy (6 MV) conventionally used with the tungsten/stainless steel target and stainless steel flattening filter. Images of phantoms and patients were acquired using the different beam lines and compared. The beam spectra and dose distributions were determined using Monte Carlo simulation. Results: The diamond target allowed use of the same beam energy as for treatment, simplifying commissioning and quality assurance. Images acquired with the diamond target at 4 MV were similar to those obtained with the graphite target at 4 MV. The slight reduction in low energy photons due to the higher-Z sintering material in the diamond target had minimal effect on image quality. Images acquired at 6 MV with the diamond target showed a small decrease in contrast-to-noise ratio, resulting from a decrease in the fraction of photons in the beam in the energy range to which the detector is most sensitive. Conclusions: The diamond target provides images of a similar quality to the graphite target. Diamond allows use of the higher beam energy conventionally used for treatment, provides a higher dose rate for the same beam current, and potentially simplifies installation and maintenance of the beam line.
引用
收藏
页码:1246 / 1253
页数:8
相关论文
共 50 条
  • [31] Anatomical background and generalized detectability in tomosynthesis and cone-beam CT
    Gang, G. J.
    Tward, D. J.
    Lee, J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2010, 37 (05) : 1948 - 1965
  • [32] Cone-Beam CT in diagnosis of scaphoid fractures
    Edlund, Rolf
    Skorpil, Mikael
    Lapidus, Gunilla
    Backlund, Jenny
    SKELETAL RADIOLOGY, 2016, 45 (02) : 197 - 204
  • [33] Low-contrast Visualization in Megavoltage Cone-beam CT at one Beam Pulse per Projection using Thick, Segmented Scintillators
    El-Mohri, Youcef
    Antonuk, Larry E.
    Zhao, Qihua
    Choroszucha, Richard B.
    Wang, Yi
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [34] Feasibility of contrast-enhanced cone-beam CT for target localization and treatment monitoring
    Rodal, Jan
    Sovik, Aste
    Skogmo, Hege Kippenes
    Knudtsen, Ingerid Skjei
    Malinen, Eirik
    RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) : 521 - 524
  • [35] Dose recalculation in megavoltage cone-beam CT for treatment evaluation: Removal of cupping and truncation artefacts in scans of the thorax and abdomen
    Petit, Steven F.
    van Elmpt, Wouter J. C.
    Lambin, Philippe
    Dekker, Andre L. A. J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (03) : 359 - 366
  • [36] Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector
    Zhao, Z.
    Gang, G. J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [37] Effect of dose reduction on image registration and image quality for cone-beam CT in radiotherapy
    Loutfi-Krauss, B.
    Koehn, J.
    Bluemer, N.
    Freundl, K.
    Koch, T.
    Kara, E.
    Scherf, C.
    Roedel, C.
    Ramm, U.
    Licher, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (02) : 192 - 200
  • [38] Beam characteristics and radiation output of a kilovoltage cone-beam CT
    Ding, George X.
    Coffey, Charles W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) : 5231 - 5248
  • [39] Multi-pass approach to reduce cone-beam artifacts in a circular orbit cone-beam CT system
    Han, Chulhee
    Baek, Jongduk
    OPTICS EXPRESS, 2019, 27 (07) : 10108 - 10126
  • [40] Use of beam shapers for cone-beam CT with off-centered flat detector
    Menser, Bernd
    Wiegert, Jens
    Wiesner, Steffen
    Bertram, Matthias
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622