A diamond target for megavoltage cone-beam CT

被引:18
|
作者
Sawkey, D. [1 ]
Lu, M. [1 ]
Morin, O. [1 ]
Aubin, M. [1 ]
Yom, S. S. [1 ]
Gottschalk, A. R. [1 ]
Bani-Hashemi, A. [2 ]
Faddegon, B. A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, Ctr Comprehens Canc, San Francisco, CA 94143 USA
[2] Siemens Healthcare Sector, Concord, CA 94520 USA
关键词
biomedical equipment; computerised tomography; diamond; dosimetry; linear accelerators; Monte Carlo methods; X-ray imaging; X-RAY-BEAMS; MONTE-CARLO; COMPUTED-TOMOGRAPHY; SIMULATION; SYSTEM; IMPLEMENTATION; LINE;
D O I
10.1118/1.3302831
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: A sintered diamond target was used in place of a graphite target as part of an imaging beam line (an unflattened beam from a graphite target) installed on a linear accelerator. The diamond target, with a greater density than the graphite target, permitted imaging at the lower beam energy (4 MV) required with the graphite target and the higher beam energy (6 MV) conventionally used with the tungsten/stainless steel target and stainless steel flattening filter. Images of phantoms and patients were acquired using the different beam lines and compared. The beam spectra and dose distributions were determined using Monte Carlo simulation. Results: The diamond target allowed use of the same beam energy as for treatment, simplifying commissioning and quality assurance. Images acquired with the diamond target at 4 MV were similar to those obtained with the graphite target at 4 MV. The slight reduction in low energy photons due to the higher-Z sintering material in the diamond target had minimal effect on image quality. Images acquired at 6 MV with the diamond target showed a small decrease in contrast-to-noise ratio, resulting from a decrease in the fraction of photons in the beam in the energy range to which the detector is most sensitive. Conclusions: The diamond target provides images of a similar quality to the graphite target. Diamond allows use of the higher beam energy conventionally used for treatment, provides a higher dose rate for the same beam current, and potentially simplifies installation and maintenance of the beam line.
引用
收藏
页码:1246 / 1253
页数:8
相关论文
共 50 条
  • [21] Crescent artifacts in cone-beam CT
    Giles, William
    Bowsher, James
    Li, Hao
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2011, 38 (04) : 2116 - 2121
  • [22] Towards cone-beam CT thermometry
    Li, Ming
    Abi-Jaoudeh, Nadine
    Kapoor, Ankur
    Kadoury, Samuel
    Xu, Sheng
    Noordhoek, Niels
    Radaelli, Alessandro
    Carelsen, Bart
    Wood, Bradford J.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [23] A Hybrid Scatter Correction Method for Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Jianxin
    Li, Lei
    Jia, Pengxiang
    Hu, Guoen
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 23 - 27
  • [24] Scalable FBP Decomposition for Cone-Beam CT Reconstruction
    Chen, Peng
    Wahib, Mohamed
    Wang, Xiao
    Hirofuchi, Takahiro
    Ogawa, Hirotaka
    Biguri, Ander
    Boardman, Richard
    Blumensath, Thomas
    Matsuoka, Satoshi
    SC21: INTERNATIONAL CONFERENCE FOR HIGH PERFORMANCE COMPUTING, NETWORKING, STORAGE AND ANALYSIS, 2021,
  • [25] A Hybrid Approach to Reduce Cone-Beam Artifacts for a Circular Orbit Cone-Beam CT System
    Choi, Shinkook
    Kim, Jinsung
    Baek, Jongduk
    IEEE ACCESS, 2018, 6 : 54595 - 54606
  • [26] Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer
    Wertz, Hansjoerg
    Stsepankou, Dzmitry
    Blessing, Manuel
    Rossi, Michael
    Knox, Chris
    Brown, Kevin
    Gros, Uwe
    Boda-Heggemann, Judit
    Walter, Cornelia
    Hesser, Juergen
    Lohr, Frank
    Wenz, Frederik
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15) : 4203 - 4217
  • [27] ESTIMATION OF ABSORBED DOSES TO TARGET AND HEALTHY TISSUES DURING CONE-BEAM CT RADIOTHERAPY IMAGING OF THE CHEST
    Marjanovic, M.
    Toth, A.
    Petrovic, B.
    Gencel, I
    ROMANIAN JOURNAL OF PHYSICS, 2021, 66 (9-10):
  • [28] Development of an MCNP-Based Cone-Beam CT Simulator
    Lim, Chang Hwy
    Cho, Mm Kook
    Han, Jong Chul
    Youn, Hanbean
    Yun, Seungman
    Cheong, Mm Ho
    Kim, Ho Kyung
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2009, 29 (04) : 351 - 359
  • [29] Radiation Dose From Cone-Beam CT in Neuroradiology Applications
    Berris, Theocharis
    Gupta, Rajiv
    Rehani, Madan M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 755 - 761
  • [30] Cone-beam CT reconstruction for planar object
    Liu, Tong