Accuracy of Scheimpflug Holladay Equivalent Keratometry Readings after Corneal Refractive Surgery in the Absence of Clinical History

被引:3
|
作者
Bialer, Omer Y. [1 ,3 ]
Kaiserman, Igor [2 ,4 ]
Bahar, Irit [1 ,3 ]
机构
[1] Rabin Med Ctr, Dept Ophthalmol, IL-49100 Petah Tiqwa, Israel
[2] Barzilai Govt Hosp, Dept Ophthalmol, Ashqelon, Israel
[3] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
[4] Ben Gurion Univ Negev, Fac Med, IL-84105 Beer Sheva, Israel
关键词
Scheimpflug camera; Equivalent keratometry reading; Intraocular lens power calculation; Cataract surgery; Pentacam; Corneal refractive surgery; LENS POWER CALCULATION; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; AXIAL LENGTH; EYES; PENTACAM; FORMULA; ADJUSTMENT;
D O I
10.1159/000363140
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background and Objective: To identify the most accurate combination of Pentacam's equivalent keratometry readings (EKR) and intraocular lens power formula when the clinical history is unavailable. Patients and Methods: A total of 18 patients underwent cataract surgery after refractive surgery. The Pentacam 4.5- and 3.0-mm EKR were combined with the SRK II, SRK/T, Hoffer-Q, and Holladay I and II formulas. Results: The smallest deviation from the predicted value was achieved by combining the 4.5 EKR with the Holladay II formula (mean arithmetic deviation, -0.2 +/- 0.4 dpt). Conclusion: The 4.5-mm EKR + Holladay II formula can accurately calculate intraocular lens power in patients with previous refractive surgery. (C) 2014 S. Karger AG, Basel
引用
收藏
页码:217 / 223
页数:7
相关论文
共 26 条
  • [1] Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery
    Tang, Qiongyan
    Hoffer, Kenneth J.
    Olson, Michael D.
    Miller, Kevin M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07) : 1198 - 1203
  • [2] Comparison of Holladay equivalent keratometry readings and anterior corneal surface keratometry measurements in keratoconus
    Saglik, Ayhan
    Celik, Hakim
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (07) : 1501 - 1509
  • [3] Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation
    Mustafa Aksoy
    Leyla Asena
    Sirel Gür Güngör
    Ali Küçüködük
    Ahmet Akman
    International Ophthalmology, 2021, 41 : 2205 - 2212
  • [4] Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation
    Aksoy, Mustafa
    Asena, Leyla
    Gungor, Sirel Gur
    Kucukoduk, Ali
    Akman, Ahmet
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (06) : 2205 - 2212
  • [5] Comparison of Holladay equivalent keratometry readings and anterior corneal surface keratometry measurements in keratoconus
    Ayhan Saglik
    Hakim Celik
    International Ophthalmology, 2019, 39 : 1501 - 1509
  • [6] New equivalent keratometry reading calculation with a rotating Scheimpflug camera for intraocular lens power calculation after myopic corneal surgery
    Seo, Kyoung Yul
    Im, Chan Young
    Yang, Hun
    Kim, Tae-im
    Kim, Eung Kweon
    Kim, Terry
    Nam, Sang Min
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11) : 1834 - 1842
  • [7] Refractive outcomes after cataract surgery: Scheimpflug keratometry versus standard automated keratometry in virgin corneas
    Lam, Sheridan
    Gupta, Balaji K.
    Hahn, John M.
    Manastersky, Natalka A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) : 1984 - 1987
  • [8] Comparing Standard Keratometry and Total Keratometry Before and After Myopic Corneal Refractive Surgery With a Swept-Source OCT Biometer
    Wang, Ziyang
    Song, Yanzheng
    Yang, Wenli
    Li, Dongjun
    Chen, Wei
    Zhao, Qi
    Liu, Qian
    Zhai, Changbin
    FRONTIERS IN MEDICINE, 2022, 9
  • [9] New Scheimpflug camera device in measuring corneal power changes after myopic laser refractive surgery
    Lanza, Michele
    Iaccarino, Stefania
    Cennamo, Michela
    Lanza, Alessandro
    Coen, Giovanni
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (02) : 115 - 119
  • [10] Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery
    Wang, Li
    Spektor, Tatyana
    de Souza, Rodrigo G.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10) : 1416 - 1421