Real-time PCR assay for ultrasensitive quantification of DNA-binding proteins

被引:13
作者
Hou, Peng
Chen, Zaozao
Ji, Meiju
He, Nongyue
Lu, Zuhong
机构
[1] Johns Hopkins Univ, Sch Med, Div Endocrinol & Metab, Baltimore, MD 21287 USA
[2] Southeast Univ, Dept Biol Sci & Med Engn, Chien Shiung Wu Lab, Nanjing, Peoples R China
关键词
D O I
10.1373/clinchem.2006.077503
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The specific binding of proteins to DNA is a key step for many cellular activities, such as transcription regulation, DNA replication, recombination, repair, and restriction. The detection of DNA-binding proteins, as well as the identification of specific binding sites, is therefore important to understand gene expression mechanisms and cellular function. We describe an ultrasensitive method for quantification of DNA-binding proteins. Methods: We combined the common exonuclease III (ExoIII) footprinting assay and real-time PCR for quantification of DNA-binding proteins, for an assay that does not require antibodies against the target proteins. Double-strand DNA probes were designed to monitor the activities of DNA-binding protein. The protein-binding site is at the 5' end of the forward primer. When a target protein is present, it will specifically bind to the protein-binding site and produce a physical hindrance to ExoIII, which protects the reverse DNA strand from digestion by ExoIII. The remaining single-strand DNA template can be quantitatively detected by real-time PCR. Conversely, in the absence of the target protein, the naked primer regions will be degraded by ExoIII, which then cannot be amplified by real-time PCR. Results: We detected the binding of 10 different transcription factors in crude cell extracts. The assay quantitatively detected binding at femtomolar concentrations of protein. Conclusions: This technique is customizable and easy to establish. It has potential applications in research, medical diagnosis, and drug discovery. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:581 / 586
页数:6
相关论文
共 26 条
[1]   A real-time immuno-PCR assay for routine ultrasensitive quantification of proteins [J].
Adler, M ;
Wacker, R ;
Niemeyer, CM .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2003, 308 (02) :240-250
[2]   DETECTION OF DNA-BINDING PROTEINS BY PROTEIN BLOTTING [J].
BOWEN, B ;
STEINBERG, J ;
LAEMMLI, UK ;
WEINTRAUB, H .
NUCLEIC ACIDS RESEARCH, 1980, 8 (01) :1-20
[3]   Exploring the DNA-binding specificities of zinc fingers with DNA microarrays [J].
Bulyk, ML ;
Huang, XH ;
Choo, Y ;
Church, GM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (13) :7158-7163
[4]   Quantifying DNA-protein interactions by double-stranded DNA arrays [J].
Bulyk, ML ;
Gentalen, E ;
Lockhart, DJ ;
Church, GM .
NATURE BIOTECHNOLOGY, 1999, 17 (06) :573-577
[5]   Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems [J].
Bustin, SA .
JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2002, 29 (01) :23-39
[6]   Exo-Dye-based assay for rapid, inexpensive, and sensitive detection of DNA-binding proteins [J].
Chen, Zaozao ;
Ji, Meiju ;
Hou, Peng ;
Lu, Zuhong .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2006, 345 (03) :1254-1263
[7]   Initiation of DNA replication in eukaryotic cells [J].
Dutta, A ;
Bell, SP .
ANNUAL REVIEW OF CELL AND DEVELOPMENTAL BIOLOGY, 1997, 13 :293-332
[8]   Proof of concept for microarray-based detection of DNA-binding oncogenes in cell extracts [J].
Egener, T ;
Roulet, E ;
Zehnder, M ;
Bucher, P ;
Mermod, N .
NUCLEIC ACIDS RESEARCH, 2005, 33 (08) :1-9
[9]   DNAASE FOOTPRINTING - SIMPLE METHOD FOR DETECTION OF PROTEIN-DNA BINDING SPECIFICITY [J].
GALAS, DJ ;
SCHMITZ, A .
NUCLEIC ACIDS RESEARCH, 1978, 5 (09) :3157-3170